Trifluralin recognition using touch-based fingertip: Application of wearable glove-based sensor toward environmental pollution and human health control.


Journal

Journal of molecular recognition : JMR
ISSN: 1099-1352
Titre abrégé: J Mol Recognit
Pays: England
ID NLM: 9004580

Informations de publication

Date de publication:
11 2021
Historique:
revised: 19 06 2021
received: 19 06 2021
accepted: 07 07 2021
pubmed: 22 7 2021
medline: 8 3 2022
entrez: 21 7 2021
Statut: ppublish

Résumé

Monitoring of herbicides and pesticides in water, food, and the environment is essential for human health, and this requires low-cost, portable devices for widespread deployment of this technology. For the first time, a wearable glove-based electrochemical sensor based on conductive Ag nano-ink was developed for the on-site monitoring of trifluralin residue on the surface of various substrates. Three electrode system with optimal thicknesses was designed directly on the finger surface of a rubber glove. Then, fabricated electrochemical sensor used for the direct detection of trifluralin in the range of 0.01 μM to 1 mM on the surface of tomato and mulberry leaves using square wave voltammetry (SWV) and difference pulse voltammetry technique. The obtained LLOQ was 0.01 μM, which indicates the suitable sensitivity of this sensor. On the other hand, this sensor is portable, easy to use, and has a high environmental capability that can be effective in detecting other chemical threats in the soil and water environment.

Identifiants

pubmed: 34288170
doi: 10.1002/jmr.2927
doi:

Substances chimiques

Herbicides 0
Trifluralin C8BX46QL7K

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

e2927

Informations de copyright

© 2021 John Wiley & Sons Ltd.

Références

Carvalho FP. Pesticides, environment, and food safety. Food Energy Secur. 2017;6(2):48-60.
Yan X, Li H, Su X. Review of optical sensors for pesticides. Trends Anal Chem. 2018;103:1-20.
Khoei AJ, Jafarzadeh Ghaleh N, Darvishi P, Rezaei K. Application of physical and biological methods to remove heavy metal, Arsenic and pesticides, Malathion and Diazinon from water. Turk J fisheries Aquatic Sciences. 2019;19(1):21-28.
Grover R, Wolt JD, Cessna AJ, Schiefer HB. Environmental fate of trifluralin. Rev Environ Contam Toxicol. 1997;4:1-64.
Bayer D, Foy CL, Mallory TE, Cutter EG. Morphological and histological effects of trifluralin on root development. Am J Bot. 1967;54(8):945-952.
Kılıç ZS, Aydın S, Bucurgat ÜÜ, Başaran N. In vitro genotoxicity assessment of dinitroaniline herbicides pendimethalin and trifluralin. Food Chem Toxicol. 2018;113:90-98.
Spencer WF, Cliath MM. Factors affecting vapor loss of trifluralin from soil. J Agric Food Chem. 1974;22(6):987-991.
Mongar K, Miller GC. Vapor phase photolysis of trifluralin in an outdoor chamber. Chemosphere. 1988;17(11):2183-2188.
Huang L-Z, Dai H, Li YJ, Gao XL. Determination of Trifluralin residues in garlic by HPLC. Food Sci. 2004;7:7-12.
Hatzisymeon M, Tataraki D, Rassias G, Aggelopoulos CA. Novel combination of high voltage nanopulses and in-soil generated plasma micro-discharges applied for the highly efficient degradation of trifluralin. J Hazard Mater. 2021;415:125646.
Golab T, Occolowitz J. Soil degradation of trifluralin: mass spectrometry of products and potential products. Biomed Mass Spectrom. 1979;6(1):1-9.
Downer GB, Hall M, Mallen DN. Determination of benefin and trifluralin residues by quantitative gas-liquid chromatography-mass spectrometry. J Agric Food Chem. 1976;24(6):1223-1225.
Amato AD, Semeraro I, Bicchi C. Simultaneous determination of linuron and trifluralin residues in carrots and their pulp by liquid chromatography and gas chromatography. J AOAC Int. 1993;76(3):657-662.
Zhang T, Qu Z, Li B, Yang Z. Simultaneous determination of atrazine, pendimethalin, and trifluralin in fish samples by QuEChERS extraction coupled with gas chromatography-electron capture detection. Food Anal Methods. 2019;12(5):1179-1186.
Dinelli G, Vicari A, Catizone P. Monitoring of herbicide pollution in water by capillary electrophoresis. J Chromatogr A. 1996;733(1-2):337-347.
Simpson AJ, Simpson MJ, Soong R. Environmental nuclear magnetic resonance spectroscopy: an overview and a primer. Anal Chem. 2018;90(1):628-639.
Székács A, Trummer N, Adányi N, Váradi M, Szendrő I. Development of a non-labeled immunosensor for the herbicide trifluralin via optical waveguide lightmode spectroscopic detection. Anal Chim Acta. 2003;487(1):31-42.
Mohanraj J, Durgalakshmi D, Rakkesh RA, Balakumar S, Rajendrand S, Karimi-Maleh H. Facile synthesis of paper based graphene electrodes for point of care devices: a double stranded DNA (dsDNA) biosensor. J Colloid Interface Sci. 2020;566:463-472.
Medetalibeyoğlu H, Beytur M, Manap S, et al. Molecular imprinted sensor including au nanoparticles/polyoxometalate/two-dimensional hexagonal boron nitride nanocomposite for diazinon recognition. ECS J Solid State Sci Technol. 2020;9:101006.
Saadati A, Hassanpour S. Lab-on-fruit skin and lab-on-leaf towards recognition of trifluralin using Ag-citrate/GQDs nanocomposite stabilized on the flexible substrate: A new platform for the electroanalysis of herbicides using direct writing of nano-inks and pen-on paper technology. Heliyon. 2020;6(12):e05779.
Jafari M, Hasanzadeh M, Karimian R, Shadjou N. Sensitive detection of Trifluralin in untreated human plasma samples using reduced graphene oxide modified by polyethylene imine and silver nanoparticles: a new platform on the analysis of pesticides and chemical injuries. Microchem J. 2019;147:741-748.
Mirabi-Semnakolaii A, Daneshgar P, Moosavi-Movahedi AA, Norouzi P, Nemati A, Farhadi M. Sensitive determination of herbicide trifluralin on the surface of copper nanowire electrochemical sensor. J Solid State Electrochem. 2011;15(9):1953-1961.
Mukhopadhyay SC. Wearable sensors for human activity monitoring: a review. IEEE Sens J. 2014;15(3):1321-1330.
Barfidokht A, Mishra RK, Seenivasan R, et al. Wearable electrochemical glove-based sensor for rapid and on-site detection of fentanyl. Sens Actuators B. 2019;296:126422.
Mishra RK, Hubble LJ, Martín A, et al. Wearable flexible and stretchable glove biosensor for on-site detection of organophosphorus chemical threats. ACS Sens. 2017;2(4):553-561.
Lee DS, Chong TW, Lee BG. Stress events detection of driver by wearable glove system. IEEE Sens J. 2016;17(1):194-204.
Xu X-Y, Yan B, Lian X. Wearable glove sensor for non-invasive organophosphorus pesticide detection based on a double-signal fluorescence strategy. Nanoscale. 2018;10(28):13722-13729.
Farshchi F, Saadati A, Fathi N, Hasanzadeh M, Samiei M. Flexible paper-based label-free electrochemical biosensor for the monitoring of miRNA-21 using core-shell ag@ au/GQD nano-ink: a new platform for the accurate and rapid analysis by low cost lab-on-paper technology. Anal Methods. 2021;13(10):1286-1294.
Farshchi F, Saadati A, Hasanzadeh M. Optimized DNA-based biosensor for monitoring Leishmania infantum in human plasma samples using biomacromolecular interaction: a novel platform for infectious disease diagnosis. Anal Methods. 2020;12(39):4759-4768.
Farschi F, Saadati A, Hasanzadeh M. A novel immunosensor for the monitoring of PSA using binding of biotinylated antibody to the prostate specific antigen based on nano-ink modified flexible paper substrate: efficient method for diagnosis of cancer using biosensing technology. Heliyon. 2020;6(7):e04327.
Ylitalo EB, Thysell E, Jernberg E, et al. Subgroups of castration-resistant prostate cancer bone metastases defined through an inverse relationship between androgen receptor activity and immune response. Eur Urol. 2017;71(5):776-787.
Irandoust M, Haghighi M, Taherpour AA, Jafarzadeh M. Electrochemical sensing of trifluralin in water by fluconazole-immobilized Fe3O4/SiO2 nanomagnetic core-shell linked to carbon nanotube modified glassy carbon electrode; an experimental and theoretical modeling. J Iran Chem Soc. 2018;15(3):719-732.
Ferro ÉC, Cardoso CA, Arruda GJ. Voltammetric detection of trifluralin in tap water, fruit juice, and vegetable extracts in the presence of surfactants. J Environ Sci Health B. 2017;52(10):762-769.
Xu N, Ding Y, Ai H, Fei J. Acetylene black-ionic liquids composite electrode: a novel platform for electrochemical sensing. Microchim Acta. 2010;170(1-2):165-170.
Sreedhar NY, Samatha KR, Kumar Reddy PR, Reddy SJ. Differential pulse polarographic determination of benfluralin and trifluralin in formulations soils and grains. Int J Environ Anal Chem. 1998;72(4):247-255.

Auteurs

Fatemeh Farshchi (F)

Pharmaceutical Analysis Research Center, Tabriz University of Medical Sciences, Tabriz, Iran.
Jiangsu Co-Innovation Center for Efficient Processing and Utilization of Forest Resources and International Innovation Center for Forest Chemicals and Materials, Nanjing Forestry University, Nanjing, China.

Arezoo Saadati (A)

Nutrition Research Center, Tabriz University of Medical Sciences, Tabriz, Iran.

Houman Kholafazad-Kordasht (H)

Drug Applied Research Center, Tabriz University of Medical Sciences, Tabriz, Iran.
Food and Drug Safety Research Center, Tabriz University of Medical Sciences, Tabriz, Iran.

Farzad Seidi (F)

Jiangsu Co-Innovation Center for Efficient Processing and Utilization of Forest Resources and International Innovation Center for Forest Chemicals and Materials, Nanjing Forestry University, Nanjing, China.

Mohammad Hasanzadeh (M)

Pharmaceutical Analysis Research Center, Tabriz University of Medical Sciences, Tabriz, Iran.
Nutrition Research Center, Tabriz University of Medical Sciences, Tabriz, Iran.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH