Comparative antibacterial activity of 2D materials coated on porous-titania.


Journal

Journal of materials chemistry. B
ISSN: 2050-7518
Titre abrégé: J Mater Chem B
Pays: England
ID NLM: 101598493

Informations de publication

Date de publication:
28 08 2021
Historique:
pubmed: 30 7 2021
medline: 5 2 2022
entrez: 29 7 2021
Statut: ppublish

Résumé

Plasma electrolytic oxidation (PEO) is a well-established technique for the treatment of titanium-based materials. The formed titania-PEO surface can improve the osseointegration properties of titanium implants. Nevertheless, it can not address bacterial infection problems associated with bone implants. Recently, 2-dimensional (2D) materials such as graphene oxide (GO), MXene, and hexagonal boron nitride (hBN) have received considerable attention for surface modifications showing their antibacterial properties. In this paper, a comparative study on the effect of partial deposition of these three materials over PEO titania substrates on the antibacterial efficiency and bioactivity is presented. Their partial deposition through drop-casting instead of continuous film coating is propsed to simultaneously address both antibacterial and osseointegration abilities. Our results demonstrate the dose-dependent nature of the deposited antibacterial agent on the PEO substrate. GO-PEO and MXene-PEO samples showed the highest antibacterial activity with 70 (±2) % and 97 (±0.5) % inactivation of S. aureus colonies in the low concentration group, respectively. Furthermore, only samples in the higher concentration group were effective against E. coli bacteria with 18 (±2) % and 17 (±4) % decrease in numbers of colonies for hBN-PEO and GO-PEO samples, respectively. Moreover, all antibacterial samples demonstrated acceptable bioactivity and good biocompatibility, making them a considerable candidates for the next generation of antibacterial titanium implants.

Identifiants

pubmed: 34323241
doi: 10.1039/d1tb01122g
doi:

Substances chimiques

Anti-Bacterial Agents 0
Boron Compounds 0
Coated Materials, Biocompatible 0
graphene oxide 0
boron nitride 2U4T60A6YD
Graphite 7782-42-5
Titanium D1JT611TNE

Types de publication

Journal Article Research Support, Non-U.S. Gov't

Langues

eng

Sous-ensembles de citation

IM

Pagination

6412-6424

Auteurs

Arash Mazinani (A)

School of Chemical Engineering and Advanced Materials, The University of Adelaide, Adelaide, SA 5005, Australia. dusan.losic@adelaide.edu.au.

Articles similaires

Vancomycin-associated DRESS demonstrates delay in AST abnormalities.

Ahmed Hussein, Kateri L Schoettinger, Jourdan Hydol-Smith et al.
1.00
Humans Drug Hypersensitivity Syndrome Vancomycin Female Male
Humans Arthroplasty, Replacement, Elbow Prosthesis-Related Infections Debridement Anti-Bacterial Agents
Vancomycin Polyesters Anti-Bacterial Agents Models, Theoretical Drug Liberation
Humans China Cerebral Hemorrhage Patient Care Bundles Length of Stay

Classifications MeSH