Limb Reconstruction Centre, Macquarie University Hospital, Macquarie University, Macquarie Park, Australia. Electronic address: munjed@almuderis.com.au.
Limb Lengthening and Complex Reconstruction Service, Osseointegration Limb Replacement Center, Hospital for Special Surgery, 535 East 70th Street, New York, NY 10021, USA. Electronic address: drjsoon@gmail.com.
MDRCBB-Minnesota Dental Research Center for Biomaterials and Biomechanics and Department of Restorative Sciences, University of Minnesota, Minneapolis, Minnesota.
McGill Craniofacial Tissue Engineering and Stem Cells Laboratory, Faculty of Dental Medicine and Oral Health Sciences, McGill University, 3640 University Street, Montreal, QC H3A 0C7, Canada.
Applied Oral Sciences and Community Dental Care, Faculty of Dentistry, The University of Hong Kong, Hong Kong Special Administrative Region of China. Electronic address: zhouye22@hku.hk.
» The purpose of this article was to review the multidisciplinary, team-based approach necessary for the optimal management of patients with limb loss undergoing osseointegration surgery.» In this stu...
Preventing bacterial infection and promoting osseointegration are essential for the long-term success of titanium (Ti) implants. In this study, we developed a multifunctional nanocoating on Ti mini-im...
To verify the influence of macrogeometry with healing chambers on the osseointegration of dental implants by analyzing implant stability quotient (ISQ) and evaluate the correlation between insertion t...
In total, 26 implants were installed in the posterior mandible of eight patients with sufficient bone height for the installation of implants measuring 3.5 mm in diameter and 9.0 mm in length. The imp...
The mean insertion torque was 43 Ncm in both groups, without a significant difference. Moreover, no significant difference in the ISQ values was found between the groups at different time points (p > ...
Furthermore, implants with a 3.5 mm diameter macrogeometry, with or without healing chambers, inserted with a drilling protocol up to 3 mm in diameter of the last helical bur, led to a similar seconda...
This study was registered retrospectively in ReBec (brazilian registry of clinical trials) under the number RBR-96n5×69, on the date of 19/06/2023....
Owing to their mechanical resilience and non-toxicity, titanium implants are widely applied as the major treatment modality for the clinical intervention against bone fractures. However, the intrinsic...
Commercially available osseointegrated devices for transfemoral amputees are limited in size and thus fail to meet the significant anatomical variability in the femoral medullary canal. This study aim...
A customized stem (OsteoCustom) was designed based on the statistical shape variability of the medullary canal. The implantability of the OsteoCustom stem was tested via 70 computed tomography (CT) im...
The OsteoCustom stem could be virtually implanted in all 70 femurs, while the OFI-C was unsuitable in 19 cases due to insufficient cortical thickness after implantation, further emphasizing its adapta...
The OsteoCustom stem performed better than the commercial stem by preserving more cortical bone and achieving a greater stem-bone contact area, especially at distal resection levels where the shape of...
Bioactive surface modifications have been proposed to enhance osseointegration and longevity of dental implants. This study aimed to systematically review and perform a meta-analysis on the effectiven...
A systematic review was conducted, including studies that investigated bioactive surface modifications on titanium dental implants. Outcomes of interest were bone-to-implant contact (BIC) and implant ...
The meta-analysis showed a significant improvement in BIC for surface-modified implants, with an overall MD of 7.29 (95% CI [2.94, 11.65]). Heterogeneity analysis indicated moderate heterogeneity (Tau...
Bioactive surface changes significantly improved osseointegration and lifespan of dental implants. Collagen-based coatings consistently encouraged early bone integration, while BMP-2 combinations were...
This study aimed to provide evidence for the clinical application of single short implants by establishing an anisotropic, three-dimensional (3D) finite element mandible model and simulating the effec...
Assuming that the bone is transversely isotropic by finite element method, we created four distinct models of implants for the mandibular first molar. Subsequently, axial and oblique forces were appli...
Upon establishing consistent osseointegration rates, the distribution of stress exhibited similarities across models with varying CIRs when subjected to vertical loads. However, when exposed to inclin...
After fixing osseointegration rates, the stress around shorter implants increased as the CIR increased under inclined loads. Thus, the effect of lateral forces should be considered when selecting shor...
Studies have not been done to evaluate the peri-implant stress exerted by materials(like PEEK and resin matrix ceramics) in different osseointegration conditions. To investigate the effect of differen...
Eighteen different 3D FEA models of implant fixed with abutment were created involving 6 different occlusal materials (Heat cured temporary acrylic resin (PMMA), Bis-GMA, PEEK, Lithium disilicate, Res...
Models were subjected to loading vertically and obliquely followed by evaluation of stress distribution....
The results of the simulation obtained were analysed in terms of Von mises, maximum principal and minimal principal stresses using descriptive stastistics....
PMMA (40.14 MPa on vertical loading and 66 MPa on oblique loading) resulted in the highest stresses and lithium disilicate (24 MPa on vertical loading and 52.40 MPa on oblique loading) resulted in lea...
Translucent zirconia and lithium disilicate offer a better stress transmission. Minimal principal stress values of PEEK and BisGMA decreased with increasing osseointegration....
To describe and evaluate the combination of osseointegration and nerve transfers in 3 transhumeral amputees....
Case series....
Three male patients with a unilateral traumatic transhumeral amputation....
Patients received a combination of osseointegration and targeted muscle reinnervation surgery. Rehabilitation included graded weight training, range of motion exercises, biofeedback, table-top prosthe...
All 3 patients attended rehabilitation and used their myoelectric prosthesis on a daily basis. Two patients had full shoulder range of motion with the prosthesis, while the other patient had 55° of ab...
These results indicate that patients can benefit from the combined procedure. However, the patients' perspective, risks of the surgical procedures, and the relatively long rehabilitation procedure nee...
Systems that capture motion under laboratory conditions limit validity in real-world environments. Mobile motion capture solutions such as Inertial Measurement Units (IMUs) can progress our understand...
Average RMSE (across all joints) between the two systems from the participant with a unilateral transfemoral amputation (TFA) on the amputated and the intact sides were 2.35° (IQR = 1.45°) and 3.59° (...
We offer a modular processing pipeline that enables the addition of extra layers, facilitates changes to the underlying biomechanical model, and can accept raw IMU data from any vendor. We successfull...