The ACS-NSQIP surgical risk calculator is a poor predictor of postoperative complications in patients undergoing oncologic distal femoral replacement.


Journal

The Knee
ISSN: 1873-5800
Titre abrégé: Knee
Pays: Netherlands
ID NLM: 9430798

Informations de publication

Date de publication:
Dec 2021
Historique:
received: 17 05 2021
revised: 20 07 2021
accepted: 31 08 2021
pubmed: 19 9 2021
medline: 15 12 2021
entrez: 18 9 2021
Statut: ppublish

Résumé

Distal femur replacement (DFR) has become a preferred reconstruction for tumors involving the femur but is associated with known complications. The ACS-NSQIP surgical risk calculator is an online tool developed to estimate postoperative complications in the first 30-days, however, has not been used in patients undergoing DFR. The purpose of this study was determining the utility of the ACS-NSQIP calculator to predict postoperative complications. 56 (30 male, 26 female) patients who underwent DFR were analyzed using the CPT codes: 27,365 (Under Excision Procedures on the Femur and Knee Joint), 27,447 (Arthroplasty, knee, condyle and plateau), 27,486 (Revision of total knee arthroplasty, with or without allograft), 27,487 (Revision of total knee arthroplasty, with or without allograft) and 27,488 (Repair, Revision, and/or Reconstruction Procedures on the Femur [Thigh Region] and Knee Joint). The predicted rates of complications were compared to the observed rates. Complications were noted in 30 (54%) of patients. The predicted risk of complications based off the CPT codes were: 27,356 (14%); 27,447 (5%); 27,486 (7%); 27,487 (8%) and 27,488 (12%). Based on ROC curves, the use of the ACS-NSQIP score were poor predictors of complications (27356, AUC 0.54); (27447, AUC 0.45); (27486, AUC 0.45); (27487, AUC 0.46); (27488, AUC 0.46). Distal femur arthroplasty performed in the setting of oncologic orthopedics is a complex procedure in a "high risk" surgical group. The ACS-NSQIP does not adequately predict the incidence of complications in these patients and cannot be reliably used in the shared decision-making process.

Sections du résumé

BACKGROUND BACKGROUND
Distal femur replacement (DFR) has become a preferred reconstruction for tumors involving the femur but is associated with known complications. The ACS-NSQIP surgical risk calculator is an online tool developed to estimate postoperative complications in the first 30-days, however, has not been used in patients undergoing DFR. The purpose of this study was determining the utility of the ACS-NSQIP calculator to predict postoperative complications.
METHODS METHODS
56 (30 male, 26 female) patients who underwent DFR were analyzed using the CPT codes: 27,365 (Under Excision Procedures on the Femur and Knee Joint), 27,447 (Arthroplasty, knee, condyle and plateau), 27,486 (Revision of total knee arthroplasty, with or without allograft), 27,487 (Revision of total knee arthroplasty, with or without allograft) and 27,488 (Repair, Revision, and/or Reconstruction Procedures on the Femur [Thigh Region] and Knee Joint). The predicted rates of complications were compared to the observed rates.
RESULTS RESULTS
Complications were noted in 30 (54%) of patients. The predicted risk of complications based off the CPT codes were: 27,356 (14%); 27,447 (5%); 27,486 (7%); 27,487 (8%) and 27,488 (12%). Based on ROC curves, the use of the ACS-NSQIP score were poor predictors of complications (27356, AUC 0.54); (27447, AUC 0.45); (27486, AUC 0.45); (27487, AUC 0.46); (27488, AUC 0.46).
CONCLUSIONS CONCLUSIONS
Distal femur arthroplasty performed in the setting of oncologic orthopedics is a complex procedure in a "high risk" surgical group. The ACS-NSQIP does not adequately predict the incidence of complications in these patients and cannot be reliably used in the shared decision-making process.

Identifiants

pubmed: 34536764
pii: S0968-0160(21)00216-7
doi: 10.1016/j.knee.2021.08.032
pii:
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

17-23

Informations de copyright

Copyright © 2021 Elsevier B.V. All rights reserved.

Déclaration de conflit d'intérêts

Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

Auteurs

Joshua R Labott (JR)

Mayo Clinic, Department of Orthopedic Surgery, Rochester, MN, United States.

Elyse J Brinkmann (EJ)

Mayo Clinic, Department of Orthopedic Surgery, Rochester, MN, United States.

Mario Hevesi (M)

Mayo Clinic, Department of Orthopedic Surgery, Rochester, MN, United States.

Cory G Couch (CG)

Mayo Clinic, Department of Orthopedic Surgery, Rochester, MN, United States.

Peter S Rose (PS)

Mayo Clinic, Department of Orthopedic Surgery, Rochester, MN, United States.

Matthew T Houdek (MT)

Mayo Clinic, Department of Orthopedic Surgery, Rochester, MN, United States. Electronic address: houdek.matthew@mayo.edu.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH