Design of a 3D printed coronary artery model for CT optimization.
Computed tomography
Image quality
Iterative reconstruction
Patient safety
Phantom
Three-dimensional printing
Journal
Radiography (London, England : 1995)
ISSN: 1532-2831
Titre abrégé: Radiography (Lond)
Pays: Netherlands
ID NLM: 9604102
Informations de publication
Date de publication:
05 2022
05 2022
Historique:
received:
12
05
2021
revised:
26
08
2021
accepted:
06
09
2021
pubmed:
25
9
2021
medline:
20
4
2022
entrez:
24
9
2021
Statut:
ppublish
Résumé
To design a custom phantom of the coronary arteries to optimize CT coronary angiography (CCTA) protocols. Characteristics of the left and right coronary arteries (mean Hounsfield Unit (HU) values and diameters) were collected from consecutive CCTA examinations (n = 43). Four different materials (two mixtures of glycerine, gelatine and water, pig hearts, Ecoflex™ silicone) were scanned inside a Lungman phantom using the CCTA protocol to find the closest model to in vivo data. A 3D printed model of the coronary artery tree was created using CCTA data by exporting a CT volume rendering into Autodesk Meshmixer™ software. The model was placed in an acid bath for 5 h, then covered in Ecoflex™, which was removed after drying. Both the Ecoflex™ and pig heart were later filled with a mixture of contrast (Visipaque 320 mg I/ml), NaCl and gelatin and scanned with different levels of tube current and iterative reconstruction (ASiR-V). Objective (HU, noise and size (vessel diameter) and subjective analysis were performed on all scans. The gelatine mixtures had HU values of 130 and 129, Ecoflex™ 65 and the pig heart 56. At the different mA/ASiR-V levels the contrast filled Ecoflex™ had a mean HU 318 ± 4, noise 47±7HU and diameter of 4.4 mm. The pig heart had a mean HU of 209 ± 5, noise 38±4HU and a diameter of 4.4 mm. With increasing iterative reconstruction level the visualisation of the pig heart arteries decreased so no measurements could be performed. The use of a 3D printed model of the arteries and casting with the Ecoflex™ silicone is the most suitable solution for a custom-designed phantom. Custom designed phantoms using 3D printing technology enable cost effective optimisation of CT protocols.
Identifiants
pubmed: 34556417
pii: S1078-8174(21)00122-X
doi: 10.1016/j.radi.2021.09.001
pii:
doi:
Substances chimiques
Silicones
0
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
426-432Informations de copyright
Copyright © 2021 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.
Déclaration de conflit d'intérêts
Conflict of interest statement None stated