Improved diagnosis of antibiotic-associated haemorrhagic colitis (AAHC) in faecal specimens by a new qualitative real-time PCR assay detecting relevant toxin genes of Klebsiella oxytoca sensu lato.
AAD
Diagnosis
Klebsiella oxytoca
Real-time PCR
Toxin genes
Journal
Clinical microbiology and infection : the official publication of the European Society of Clinical Microbiology and Infectious Diseases
ISSN: 1469-0691
Titre abrégé: Clin Microbiol Infect
Pays: England
ID NLM: 9516420
Informations de publication
Date de publication:
May 2022
May 2022
Historique:
received:
24
02
2021
revised:
27
08
2021
accepted:
15
09
2021
pubmed:
29
9
2021
medline:
4
5
2022
entrez:
28
9
2021
Statut:
ppublish
Résumé
Toxin-producing Klebsiella oxytoca causes antibiotic-associated haemorrhagic colitis (AAHC). The disease-relevant cytotoxins tilivalline and tilimycine produced by certain K. oxytoca isolates are encoded by the non-ribosomal peptide synthetase genes A (npsA) and B (npsB). In this study, the new LightMix® Modular kit for the detection of relevant K. oxytoca sensu lato (s.l.) toxin genes was evaluated. DNA was extracted on the automated EMAG® platform. Amplification was done on the Light Cycler® 480 II instrument. In total, 130 residual faecal specimens collected from patients with antibiotic-associated diarrhoea were studied to determine the clinical sensitivity and specificity. Toxigenic culture served as reference method. With the new kit, the limit of detection was 15 CFU/mL for all targets. For the pehX target specific to K. oxytoca s.l., 65 of 130 clinical specimens were positive, while toxin-specific targets (npsA/npsB) were positive in 47 of 130. The npsA/npsB PCR targets showed a clinical sensitivity of 100% (95%CI 80.5-100%) and a specificity of 73.5% (95%CI 64.3-81.3%) with a positive predictive value of 16.5% (95%CI 12.7-21.2%) and a negative predictive value of 100%. Compared with culture, additional clinical specimens positive for K. oxytoca s.l. were detected with real-time PCR. The specificity of the toxin targets appears moderate due to the inferior sensitivity of the culture-based reference method. Since the developed assay is highly sensitive, it may be used as first-line method to improve the diagnosis of AAHC.
Identifiants
pubmed: 34582979
pii: S1198-743X(21)00537-1
doi: 10.1016/j.cmi.2021.09.017
pii:
doi:
Substances chimiques
Anti-Bacterial Agents
0
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
690-694Informations de copyright
Copyright © 2021 The Authors. Published by Elsevier Ltd.. All rights reserved.