Prospective De Novo Donor-Specific Antibody Monitoring in Renal Transplant Patients.
Journal
Transplantation proceedings
ISSN: 1873-2623
Titre abrégé: Transplant Proc
Pays: United States
ID NLM: 0243532
Informations de publication
Date de publication:
Nov 2021
Nov 2021
Historique:
received:
01
06
2021
revised:
27
07
2021
accepted:
24
08
2021
pubmed:
3
10
2021
medline:
1
12
2021
entrez:
2
10
2021
Statut:
ppublish
Résumé
De novo donor-specific antibodies (dnDSA) are associated with antibody-mediated rejection leading to kidney transplant failure. However, many transplant patients are stable with no signs of graft dysfunction at the time of dnDSA detection at screening test. We prospectively studied 26 kidney transplant patients for 3 years, with dnDSA detected using the Luminex single-antigen bead assay in a routine test. Proteinuria and estimated glomerular filtration rate were evaluated along with dnDSA monitoring at least annually. Graft loss associated with dnDSA occurred in 8 (31%) patients, 14 ± 11 months after the initial detection of dnDSA. These patients had more frequently multiple dnDSA (P = .004) and remarkable proteinuria, more than 1 g daily (P < .001). The remaining 18 patients were followed for 38 ± 15 months and considered stable as there was no deterioration regarding estimated glomerular filtration rate and proteinuria. In 7 (39%) of these patients, dnDSA waned and were not detected anymore at follow-up. Antibodies against HLA class I had a significantly (P < .001) lower mean fluorescence intensity (MFI) (2603 ± 1098) compared with those against HLA class II (11,109 ± 6414). In regression analysis, they were predictive of dnDSA wane (P = .043; odds ratio, 0.18; 95% confidence interval, 0.04-0.94). Despite fluctuations during follow-up, there was no significant change in MFI for those who retained the dnDSA. The presence of dnDSA is transient in a significant proportion of stable renal transplant patients, especially in those with antibodies against HLA class I and a low MFI. Multiple dnDSA and severe proteinuria adversely affect renal graft survival.
Sections du résumé
BACKGROUND
BACKGROUND
De novo donor-specific antibodies (dnDSA) are associated with antibody-mediated rejection leading to kidney transplant failure. However, many transplant patients are stable with no signs of graft dysfunction at the time of dnDSA detection at screening test.
METHODS
METHODS
We prospectively studied 26 kidney transplant patients for 3 years, with dnDSA detected using the Luminex single-antigen bead assay in a routine test. Proteinuria and estimated glomerular filtration rate were evaluated along with dnDSA monitoring at least annually.
RESULTS
RESULTS
Graft loss associated with dnDSA occurred in 8 (31%) patients, 14 ± 11 months after the initial detection of dnDSA. These patients had more frequently multiple dnDSA (P = .004) and remarkable proteinuria, more than 1 g daily (P < .001). The remaining 18 patients were followed for 38 ± 15 months and considered stable as there was no deterioration regarding estimated glomerular filtration rate and proteinuria. In 7 (39%) of these patients, dnDSA waned and were not detected anymore at follow-up. Antibodies against HLA class I had a significantly (P < .001) lower mean fluorescence intensity (MFI) (2603 ± 1098) compared with those against HLA class II (11,109 ± 6414). In regression analysis, they were predictive of dnDSA wane (P = .043; odds ratio, 0.18; 95% confidence interval, 0.04-0.94). Despite fluctuations during follow-up, there was no significant change in MFI for those who retained the dnDSA.
CONCLUSIONS
CONCLUSIONS
The presence of dnDSA is transient in a significant proportion of stable renal transplant patients, especially in those with antibodies against HLA class I and a low MFI. Multiple dnDSA and severe proteinuria adversely affect renal graft survival.
Identifiants
pubmed: 34598809
pii: S0041-1345(21)00587-X
doi: 10.1016/j.transproceed.2021.08.032
pii:
doi:
Substances chimiques
HLA Antigens
0
Isoantibodies
0
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
2765-2768Informations de copyright
Copyright © 2021 Elsevier Inc. All rights reserved.