Breast Computed Tomography: Diagnostic Performance of the Maximum Intensity Projection Reformations as a Stand-Alone Method for the Detection and Characterization of Breast Findings.


Journal

Investigative radiology
ISSN: 1536-0210
Titre abrégé: Invest Radiol
Pays: United States
ID NLM: 0045377

Informations de publication

Date de publication:
01 04 2022
Historique:
pubmed: 6 10 2021
medline: 10 5 2022
entrez: 5 10 2021
Statut: ppublish

Résumé

This study aimed to evaluate the diagnostic performance of the maximum intensity projection (MIP) reformations of breast computed tomography (B-CT) images as a stand-alone method for the detection and characterization of breast imaging findings. A total of 160 women undergoing B-CT between August 2018 and December 2020 were retrospectively included; 80 patients with known breast imaging findings were matched with 80 patients without imaging findings according to age and amount of fibroglandular tissue (FGT). A total of 71 benign and 9 malignant lesions were included. Images were evaluated using 15-mm MIP in 3 planes by 2 radiologists with experience in B-CT. The presence of lesions and FGT were evaluated, using the BI-RADS classification. Interreader agreement and descriptive statistics were calculated. The interreader agreement of the 2 readers for finding a lesion (benign or malignant) was 0.86 and for rating according to BI-RADS classification was 0.82. One of 9 cancers (11.1%) was missed by both readers due to dense breast tissue. BI-RADS 1 was correctly applied to 73 of 80 patients (91.3%) by reader 1 and to 74 of 80 patients (92.5%) by reader 2 without recognizable lesions. BI-RADS 2 or higher with a lesion in at least one of the breasts was correctly applied in 69 of 80 patients (86.3%) by both readers. For finding a malignant lesion, sensitivity was 88.9% (95% confidence interval [CI], 51.75%-99.72%) for both readers, and specificity was 99.3% (95% CI, 96.4%-100%) for reader 1 and 100% (95% CI, 97.20%-100.00%) for reader 2. Evaluation of B-CT images using the MIP reformations may help to reduce the reading time with high diagnostic performance and confidence.

Identifiants

pubmed: 34610622
doi: 10.1097/RLI.0000000000000829
pii: 00004424-202204000-00001
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

205-211

Informations de copyright

Copyright © 2021 Wolters Kluwer Health, Inc. All rights reserved.

Déclaration de conflit d'intérêts

Conflicts of interest and sources of funding: none declared.

Références

Malvezzi M, Carioli G, Bertuccio P, et al. European cancer mortality predictions for the year 2019 with focus on breast cancer. Ann Oncol . 2019;30:781–787.
Niell BL, Freer PE, Weinfurtner RJ, et al. Screening for breast cancer. Radiol Clin North Am . 2017;55:1145–1162.
Whelehan P, Evans A, Wells M, et al. The effect of mammography pain on repeat participation in breast cancer screening: a systematic review. Breast . 2013;22:389–394.
Henrot P, Boisserie-Lacroix M, Boute V, et al. Self-compression technique vs standard compression in mammography: a randomized clinical trial. JAMA Intern Med . 2019;179:407–414.
Berger N, Marcon M, Saltybaeva N, et al. Dedicated breast computed tomography with a photon-counting detector: initial results of clinical in vivo imaging. Invest Radiol . 2019;54:409–418.
O'Connell AM, Kawakyu-O'Connor D. Dedicated cone-beam breast computed tomography and diagnostic mammography: comparison of radiation dose, patient comfort, and qualitative review of imaging findings in BI-RADS 4 and 5 lesions. J Clin Imaging Sci . 2012;2:7.
Berger N, Marcon M, Frauenfelder T, et al. Dedicated spiral breast computed tomography with a single photon-counting detector: initial results of the first 300 women. Invest Radiol . 2020;55:68–72.
Kalender WA, Kolditz D, Steiding C, et al. Technical feasibility proof for high-resolution low-dose photon-counting CT of the breast. Eur Radiol . 2017;27:1081–1086.
Shim S, Saltybaeva N, Berger N, et al. Lesion detectability and radiation dose in spiral breast CT with photon-counting detector technology: a phantom study. Invest Radiol . 2020;55:515–523.
Wieler J, Berger N, Frauenfelder T, et al. Breast density in dedicated breast computed tomography: proposal of a classification system and interreader reliability. Medicine (Baltimore) . 2021;100:e25844.
Wienbeck S, Fischer U, Luftner-Nagel S, et al. Contrast-enhanced cone-beam breast-CT (CBBCT): clinical performance compared to mammography and MRI. Eur Radiol . 2018;28:3731–3741.
Aminololama-Shakeri S, Hargreaves JB, Boone JM, et al. Dedicated breast CT: screening technique of the future. Curr Breast Cancer Rep . 2016;8:242–247.
Dang PA, Freer PE, Humphrey KL, et al. Addition of tomosynthesis to conventional digital mammography: effect on image interpretation time of screening examinations. Radiology . 2014;270:49–56.
O'Connell A, Conover DL, Zhang Y, et al. Cone-beam CT for breast imaging: radiation dose, breast coverage, and image quality. AJR Am J Roentgenol . 2010;195:496–509.
Clauser P, Baltzer PAT, Kapetas P, et al. Synthetic 2-dimensional mammography can replace digital mammography as an adjunct to wide-angle digital Breast Tomosynthesis. Invest Radiol . 2019;54:83–88.
Gruden JF, Ouanounou S, Tigges S, et al. Incremental benefit of maximum-intensity-projection images on observer detection of small pulmonary nodules revealed by multidetector CT. AJR Am J Roentgenol . 2002;179:149–157.
Napel S, Rubin GD, Jeffrey RB Jr. STS-MIP: a new reconstruction technique for CT of the chest. J Comput Assist Tomogr . 1993;17:832–838.
Abdullah P, Alabousi M, Ramadan S, et al. Synthetic 2D mammography versus standard 2D digital mammography: a diagnostic test accuracy systematic review and Meta-analysis. AJR Am J Roentgenol . 2021;217:314–325.
Morris EA, Comstock CE, Lee CH, et al. ACR BI-RADS® magnetic resonance imaging. In: ACR BI-RADS® Atlas, Breast Imaging Reporting and Data System . Reston, VA: American College of Radiology; 2013.
Sickles E, D'Orsi CJ, Bassett LW, et al. ACR BI-RADS® mammography. In: ACR BI-RADS® Atlas, Breast Imaging Reporting and Data System . Reston, VA: American College of Radiology; 2013.
McHugh ML. Interrater reliability: the kappa statistic. Biochem Med (Zagreb) . 2012;22:276–282.
Ruby L, Shim S, Berger N, et al. Diagnostic value of a spiral breast computed tomography system equipped with photon counting detector technology in patients with implants: an observational study of our initial experiences. Medicine (Baltimore) . 2020;99:e20797.
Jung HK, Kuzmiak CM, Kim KW, et al. Potential use of American College of Radiology BI-RADS mammography atlas for reporting and assessing lesions detected on dedicated breast CT imaging: preliminary study. Acad Radiol . 2017;24:1395–1401.
Ekpo EU, Ujong UP, Mello-Thoms C, et al. Assessment of interradiologist agreement regarding mammographic breast density classification using the fifth edition of the BI-RADS atlas. AJR Am J Roentgenol . 2016;206:1119–1123.

Auteurs

Nicole Berger (N)

From the Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland.

Jann Wieler (J)

From the Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland.

Dania Cioni (D)

Department of Translational Research, University of Pisa, Pisa, Italy.

Emanuele Neri (E)

Department of Translational Research, University of Pisa, Pisa, Italy.

Andreas Boss (A)

From the Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland.

Thomas Frauenfelder (T)

From the Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland.

Magda Marcon (M)

From the Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH