Acute changes in mitral valve geometry after percutaneous valve repair with MitraClip XT
3D echocardiography
MitraClip procedure
mitral annulus
mitral valve quantification
Journal
Echocardiography (Mount Kisco, N.Y.)
ISSN: 1540-8175
Titre abrégé: Echocardiography
Pays: United States
ID NLM: 8511187
Informations de publication
Date de publication:
11 2021
11 2021
Historique:
revised:
13
08
2021
received:
18
03
2021
accepted:
13
10
2021
pubmed:
11
11
2021
medline:
27
1
2022
entrez:
10
11
2021
Statut:
ppublish
Résumé
Mitral valve (MV) repair with MitraClip system is a safe treatment option for high-risk patients with significant mitral regurgitation (MR). We aimed to characterize, by three-dimensional echocardiography (3D-E), changes occurring in MV after implantation of third generation MitraClip XT We prospectively enrolled 59 patients, who underwent intra-procedural 3D-E before and after device deployment. Three-D datasets were analyzed off-line, using a dedicated semiautomatic software, to obtain parametric quantification of mitral anatomy. Post-procedural MR of mild or lesser degree was achieved in 40 patients (68%), with no differences between FMR and DMR (p 0.9). After MitraClip XT MitraClip XT
Sections du résumé
BACKGROUND
Mitral valve (MV) repair with MitraClip system is a safe treatment option for high-risk patients with significant mitral regurgitation (MR). We aimed to characterize, by three-dimensional echocardiography (3D-E), changes occurring in MV after implantation of third generation MitraClip XT
METHODS
We prospectively enrolled 59 patients, who underwent intra-procedural 3D-E before and after device deployment. Three-D datasets were analyzed off-line, using a dedicated semiautomatic software, to obtain parametric quantification of mitral anatomy.
RESULTS
Post-procedural MR of mild or lesser degree was achieved in 40 patients (68%), with no differences between FMR and DMR (p 0.9). After MitraClip XT
CONCLUSIONS
MitraClip XT
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
1913-1923Informations de copyright
© 2021 Wiley Periodicals LLC.
Références
Baumgartner H, Falk V, Bax JJ, et al. 2017 ESC/EACTS guidelines for the management of valvular heart disease. Eur Heart J. 2017;38(36):2739-2786.
Feldman T, Kar S, Elmariah S, et al. Randomized comparison of percutaneous repair and surgery for mitral regurgitation 5-year results of EVEREST II. J Am Coll Cardiol. 2015;66(25):2844-2854.
Fail PS, Smalling RW, Ph D, et al. Percutaneous repair or surgery for mitral regurgitation. N Engl J Med. 2011;364(15):1395-1406.
Remy T, Bertog SC, Wunderlich N, et al. Change in mitral annular size and geometry after mitraclip® implantation in patients with functional and degenerative mitral regurgitation. J Interv Cardiol. 2014;27(5):516-524.
Al Amri I, Debonnaire P, Van Der Kley F, et al. Acute effect of MitraClip implantation on mitral valve geometry in patients with functional mitral regurgitation: insights from three-dimensional transoesophageal echocardiography. EuroIntervention. 2016;11(13):1554-1561.
Schueler R, Kaplan S, Melzer C, et al. Impact of interventional edge-to-edge repair on mitral valve geometry. Int J Cardiol. 2017;230:468-475.
Patzelt J, Zhang Y, Magunia H, et al. Improved mitral valve coaptation and reduced mitral valve annular size after percutaneous mitral valve repair (PMVR) using the MitraClip system. Eur Heart J Cardiovasc Imag. 2018;19(7):785-791.
Schmidt FP, Von Bardeleben RS, Nikolai P, et al. Immediate effect of the MitraClip® procedure on mitral ring geometry in primary and secondary mitral regurgitation. Eur Heart J Cardiovasc Imag. 2013;14(9):851-857.
Donmez E, Salcedo EE, Quaife RA, et al. The acute effects of edge-to-edge percutaneous mitral valve repair on the shape and size of the mitral annulus and its relation to mitral regurgitation. Echocardiography. 2019;36(4):732-741.
Noack T, Kiefer P, Mallon L, et al. Changes in dynamic mitral valve geometry during percutaneous edge-edge mitral valve repair with the MitraClip system. J Echocardiogr. 2019;17(2):84-94.
Kreidel F, Zaid S, Tamm AR, et al. Impact of Mitral Annular Dilation on Edge-to-Edge Therapy With MitraClip-XTR. Circ Cardiovasc Interv. 2021;(August):1-10.
Praz F, Braun D, Unterhuber M, et al. Edge-to-edge mitral valve repair with extended clip arms: early experience from a multicenter observational study. JACC Cardiovasc Interv. 2019;12(14):1356-1365.
Aquila I, González A, Fernández-Golfín C, et al. Reproducibility of a novel echocardiographic 3D automated software for the assessment of mitral valve anatomy. Cardiovasc Ultrasound. 2016;14(1):1-8.
Tsang W, Weinert L, Sugeng L, et al. The value of three-dimensional echocardiography derived mitral valve parametric maps and the role of experience in the diagnosis of pathology. J Am Soc Echocardiogr. 2011;24(8):860-867.
Wunderlich NC, Siegel RJ. Peri-interventional echo assessment for the MitraClip procedure. Eur Heart J Cardiovasc Imag. 2013;14(10):935-949.
Lang RM, Badano LP, Victor MA, et al. Recommendations for cardiac chamber quantification by echocardiography in adults: an update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging. J Am Soc Echocardiogr. 2015;28(1):1-39.e14.
Zoghbi WA, Adams D, Bonow RO, et al. Recommendations for noninvasive evaluation of native valvular regurgitation a report from the American Society of Echocardiography developed in collaboration with the society for cardiovascular magnetic resonance. J Am Soc Echocardiogr. 2017;30(4):303-371.
Lancellotti P, Tribouilloy C, Hagendorff A, et al. Recommendations for the echocardiographic assessment of native valvular regurgitation: an executive summary from the European association of cardiovascular imaging. Eur Heart J Cardiovasc Imag. 2013;14(7):611-644.
Zoghbi WA, Asch FM, Bruce C, et al. Guidelines for the evaluation of valvular regurgitation after percutaneous valve repair or replacement: a report from the American Society of Echocardiography developed in collaboration with the society for cardiovascular angiography and interventions, J Am Soc Echocardiogr. 2019;32(4):431-475.
Avenatti E, Mackensen GB, El-Tallawi KC, et al. Diagnostic value of 3-dimensional vena contracta area for the quantification of residual mitral regurgitation after MitraClip procedure. JACC Cardiovasc Interv. 2019;12(6):582-591.
Lang RM, Badano LP, Tsang W, et al. EAE /ASE recommendations for image acquisition and display using three-dimensional echocardiography. Eur Heart J Cardiovasc Imag. 2012;13(1):1-46.
Van Wijngaarden SE, Kamperidis V, Regeer M V., et al. Three-dimensional assessment of mitral valve annulus dynamics and impact on quantification of mitral regurgitation. Eur Heart J Cardiovasc Imag. 2018;19(2):176-184.
Garbi M, Monaghan MJ. Quantitative mitral valve anatomy and pathology. Echo Res Pract. 2015 Sep 1;2(3):R63-R72.
Weinmann K, Markovic S, Rottbauer W, et al. First experience with the MitraClip XTR device for extensive mitral valve prolapse (Barlow's disease). EuroIntervention. 2018 Dec 20;14(12):e1276-e1277.
Al-Hijji M, El Sabbagh A, Fender EA, et al. Utility of MitraClip XTR system in percutaneous edge-to-edge mitral valve repair for severe flail leaflet. Heart Views. Jan-Mar 2020;21(1):45-48.
Bedogni F, Popolo Rubbio A, Grasso C, et al. Italian Society of Interventional Cardiology (GIse) registry Of Transcatheter treatment of mitral valve regurgitaTiOn (GIOTTO): impact of valve disease aetiology and residual mitral regurgitation after MitraClip implantation. Eur J Heart Fail. 2021.
Agricola E, Oppizzi M, Maisano F, et al. Echocardiographic classification of chronic ischemic mitral regurgitation caused by restricted motion according to tethering pattern. Eur J Echocardiogr. 2004;5(5):326-334.
Mantegazza V, Pasquini A, Agati L, et al. Comprehensive assessment of mitral valve geometry and cardiac remodeling with 3-dimensional echocardiography after percutaneous mitral valve repair. Am J Cardiol. 2018;122(7):1195-1203.
Lim DS. Contemporary Outcomes with MitraClipTM (NTR/XTR) System in Primary Mitral Regurgitation: Results from the Global EXPAND Study. Presented at American Collage of Cardiologiy - Chicago, Illinois; March 28-30, 2020.
Warraich HJ, Chaudary B, Maslow A, et al. Mitral annular nonplanarity: correlation between annular height/commissural width ratio and the nonplanarity angle. J Cardiothorac Vasc Anesth. 2012;26(2):186-90.
Salgo IS, Gorman JH, Gorman RC, et al. Effect of annular shape on leaflet curvature in reducing mitral leaflet stress. Circulation. 2002;106(6):711-717.
Bartels K, Thiele RH, Phillips-Bute B, et al. Dynamic indices of mitral valve function using perioperative three-dimensional transesophageal echocardiography. J Cardiothorac Vasc Anesth. 2014;28(1):18-24.
Kim J, Palumbo MC, Khalique OK, et al. Transcatheter MitraClip repair alters mitral annular geometry - device induced annular remodeling on three-dimensional echocardiography predicts therapeutic response. Cardiovasc Ultrasound. 2019;17(1):1-11.
Magne J, Pibarot P, Dagenais F, et al. Outcome after restrictive mitral valve annuloplasty for ischemic mitral regurgitation. Circulation. 2007;115(6):782-91.
Feldman T, Kar S, Rinaldi M, et al. Percutaneous mitral repair with the MitraClip system: safety and midterm durability in the initial EVEREST (Endovascular Valve Edge-to-Edge REpair Study) cohort. J Am Coll Cardiol. 2009 Aug 18;54(8):686-94.
Stone GW, Lindenfeld JA, Abraham WT, et al. Transcatheter mitral-valve repair in patients with heart failure. N Engl J Med. 2018;379(24):2307-2318.
Obadia JF, Messika-Zeitoun D, Leurent G, et al. Percutaneous repair or medical treatment for secondary mitral regurgitation. N Engl J Med. 2018;379(24):2297-2306.