Percutaneous Kidney Puncture with Three-dimensional Mixed-reality Hologram Guidance: From Preoperative Planning to Intraoperative Navigation.

Holograms Hyper Accuracy 3D Image-guided surgery Kidney stones Mixed reality Three-dimensional reconstruction

Journal

European urology
ISSN: 1873-7560
Titre abrégé: Eur Urol
Pays: Switzerland
ID NLM: 7512719

Informations de publication

Date de publication:
06 2022
Historique:
received: 14 02 2021
revised: 05 09 2021
accepted: 15 10 2021
pubmed: 21 11 2021
medline: 3 6 2022
entrez: 20 11 2021
Statut: ppublish

Résumé

Despite technical and technological innovations, percutaneous puncture still represents the most challenging step when performing percutaneous nephrolithotomy. This maneuver is characterized by the steepest learning curve and a risk of injuring surrounding organs and kidney damage. To evaluate the feasibility of three-dimensional mixed reality (3D MR) holograms in establishing the access point and guiding the needle during percutaneous kidney puncture. This prospective study included ten patients who underwent 3D MR endoscopic combined intrarenal surgery (ECIRS) for kidney stones from July 2019 to January 2020. A retrospective series of patients who underwent a standard procedure were selected for matched pair analysis. For patients who underwent 3D MR ECIRS, holograms were overlapped on the real anatomy to guide the surgeon during percutaneous puncture. In the standard group, the procedures were only guided by ultrasound and fluoroscopy. Differences in preoperative and postoperative patient characteristics between the groups were tested using a χ Ten patients underwent 3D MR ECIRS. In all cases, the inferior calyx was punctured correctly, as planned using the overlapping hologram. The median puncture and radiation exposure times were 27 min and 120 s, respectively. No intraoperative or major postoperative complications occurred. Matched pair analysis with the standard ECIRS group revealed a significantly shorter radiation exposure time for the 3D MR group (p < 0.001) even though the puncture time was longer in comparison to the standard group (p < 0.001). Finally, use of 3D MR led to a higher success rate for renal puncture at the first attempt (100% vs 50%; p = 0.032). The main limitations of the study are the small sample size and manual overlapping of the rigid hologram models. Our experience demonstrates that 3D MR guidance for renal puncture is feasible and safe. The procedure proved to be effective, with the inferior calyx correctly punctured in all cases, and was associated with a low intraoperative radiation exposure time because of the MR guidance. Three-dimensional virtual models visualized as holograms and intraoperatively overlapped on the patient's real anatomy seem to be a valid new tool for guiding puncture of the kidney through the skin for minimally invasive treatment.

Sections du résumé

BACKGROUND
Despite technical and technological innovations, percutaneous puncture still represents the most challenging step when performing percutaneous nephrolithotomy. This maneuver is characterized by the steepest learning curve and a risk of injuring surrounding organs and kidney damage.
OBJECTIVE
To evaluate the feasibility of three-dimensional mixed reality (3D MR) holograms in establishing the access point and guiding the needle during percutaneous kidney puncture.
DESIGN, SETTING, AND PARTICIPANTS
This prospective study included ten patients who underwent 3D MR endoscopic combined intrarenal surgery (ECIRS) for kidney stones from July 2019 to January 2020. A retrospective series of patients who underwent a standard procedure were selected for matched pair analysis.
SURGICAL PROCEDURE
For patients who underwent 3D MR ECIRS, holograms were overlapped on the real anatomy to guide the surgeon during percutaneous puncture. In the standard group, the procedures were only guided by ultrasound and fluoroscopy.
MEASUREMENTS
Differences in preoperative and postoperative patient characteristics between the groups were tested using a χ
RESULTS AND LIMITATIONS
Ten patients underwent 3D MR ECIRS. In all cases, the inferior calyx was punctured correctly, as planned using the overlapping hologram. The median puncture and radiation exposure times were 27 min and 120 s, respectively. No intraoperative or major postoperative complications occurred. Matched pair analysis with the standard ECIRS group revealed a significantly shorter radiation exposure time for the 3D MR group (p < 0.001) even though the puncture time was longer in comparison to the standard group (p < 0.001). Finally, use of 3D MR led to a higher success rate for renal puncture at the first attempt (100% vs 50%; p = 0.032). The main limitations of the study are the small sample size and manual overlapping of the rigid hologram models.
CONCLUSIONS
Our experience demonstrates that 3D MR guidance for renal puncture is feasible and safe. The procedure proved to be effective, with the inferior calyx correctly punctured in all cases, and was associated with a low intraoperative radiation exposure time because of the MR guidance.
PATIENT SUMMARY
Three-dimensional virtual models visualized as holograms and intraoperatively overlapped on the patient's real anatomy seem to be a valid new tool for guiding puncture of the kidney through the skin for minimally invasive treatment.

Identifiants

pubmed: 34799199
pii: S0302-2838(21)02124-2
doi: 10.1016/j.eururo.2021.10.023
pii:
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

588-597

Informations de copyright

Copyright © 2021 European Association of Urology. Published by Elsevier B.V. All rights reserved.

Auteurs

Francesco Porpiglia (F)

Division of Urology, Department Of Oncology, School of Medicine, University of Turin, San Luigi Hospital, Orbassano, Turin, Italy.

Enrico Checcucci (E)

Division of Urology, Department Of Oncology, School of Medicine, University of Turin, San Luigi Hospital, Orbassano, Turin, Italy; Department of Surgery, Candiolo Cancer Institute, FPO-IRCCS, Candiolo, Turin, Italy; Uro-technology and Social Media Working Group of the Young Academic Urologists of the European Association of Urology, Arnhem, The Netherlands. Electronic address: checcu.e@hotmail.it.

Daniele Amparore (D)

Division of Urology, Department Of Oncology, School of Medicine, University of Turin, San Luigi Hospital, Orbassano, Turin, Italy.

Dario Peretti (D)

Division of Urology, Department Of Oncology, School of Medicine, University of Turin, San Luigi Hospital, Orbassano, Turin, Italy.

Federico Piramide (F)

Division of Urology, Department Of Oncology, School of Medicine, University of Turin, San Luigi Hospital, Orbassano, Turin, Italy.

Sabrina De Cillis (S)

Division of Urology, Department Of Oncology, School of Medicine, University of Turin, San Luigi Hospital, Orbassano, Turin, Italy.

Alberto Piana (A)

Division of Urology, Department Of Oncology, School of Medicine, University of Turin, San Luigi Hospital, Orbassano, Turin, Italy.

Gabriel Niculescu (G)

Division of Urology, Department Of Oncology, School of Medicine, University of Turin, San Luigi Hospital, Orbassano, Turin, Italy.

Paolo Verri (P)

Division of Urology, Department Of Oncology, School of Medicine, University of Turin, San Luigi Hospital, Orbassano, Turin, Italy.

Matteo Manfredi (M)

Division of Urology, Department Of Oncology, School of Medicine, University of Turin, San Luigi Hospital, Orbassano, Turin, Italy.

Massimiliano Poggio (M)

Division of Urology, Department Of Oncology, School of Medicine, University of Turin, San Luigi Hospital, Orbassano, Turin, Italy.

Ilaria Stura (I)

Department of Public Health and Pediatric Sciences, School of Medicine, University of Turin, Turin, Italy.

Giuseppe Migliaretti (G)

Department of Public Health and Pediatric Sciences, School of Medicine, University of Turin, Turin, Italy.

Marco Cossu (M)

Division of Urology, Department Of Oncology, School of Medicine, University of Turin, San Luigi Hospital, Orbassano, Turin, Italy.

Cristian Fiori (C)

Division of Urology, Department Of Oncology, School of Medicine, University of Turin, San Luigi Hospital, Orbassano, Turin, Italy.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH