What Is the Impact of Automated Synovial Cell Counting on Different Aseptic Causes and Periprosthetic Conditions Associated With Revision THA?


Journal

Clinical orthopaedics and related research
ISSN: 1528-1132
Titre abrégé: Clin Orthop Relat Res
Pays: United States
ID NLM: 0075674

Informations de publication

Date de publication:
01 05 2022
Historique:
received: 11 09 2021
accepted: 03 11 2021
pubmed: 2 12 2021
medline: 22 4 2022
entrez: 1 12 2021
Statut: ppublish

Résumé

Studies have suggested that automated synovial cell counting may overestimate the white blood cell (WBC) count, resulting in false positive tests when evaluating patients for the possibility of periprosthetic joint infection (PJI) after THA. However, associations between WBC counts high enough to mimic PJI in patients whose arthroplasties are not infected but rather are experiencing a variety of aseptic problems-including but not limited to metallosis, polyethylene wear, and recurrent dislocation-have not, to our knowledge, been adequately addressed. In addition, there is a lack of analyses about the polymorphonuclear percentage (PMN%) when assessed by automated analyzers in this context. In the context of different indications for aseptic revision and different periprosthetic hip pathologic findings, we asked: (1) What were the synovial WBC count levels, and what proportion of values were above the 2018 International Consensus Meeting (ICM) cutoff (3000 cells/μL)? (2) What were the synovial PMN% levels, and what proportion of values were above the 2018 ICM (70%)? We retrospectively studied the preoperative cell count analyses of synovial fluid in patients who underwent revision THA for aseptic reasons at our tertiary referral arthroplasty center between January 2015 and December 2017. We considered all revisions performed on patients during that time potentially eligible, and after prespecified exclusions were applied (exclusions mainly included 15% [197 of 1306] sporadic missing data and 12% [155 of 1306] insufficient synovial fluid obtained in the aspirate), a total of 702 patients undergoing revision THA for aseptic reasons remained for the final analysis. As far as we know, no patients underwent re-revision for PJI at a mean follow-up of 46 ± 11 months, which tends to confirm our impression that indeed these hips did not have PJI. Cell count analyses were conducted using an automated analyzer. Clinical findings, preoperative radiographs, and surgical reports--confirmed by available histologic results--were used to establish diagnoses. We evaluated these hips considering the recommendations of the 2018 ICM (WBC count of 3000 cells/μL and PMN% of 70%) to see what proportion of them would have been characterized as likely having PJI on basis of those cutoff values. The mean WBC count for the entire cohort was 2120 ± 2395 cells/μL. The mean PMN% for the entire cohort was 36% ± 22%. Compared with aseptic loosening and recurrent dislocation, polyethylene wear had the highest mean WBC count (3817 ± 3711 cells/μL; p < 0.001). Of the investigated periprosthetic conditions, wear-induced synovitis had the highest value (4464 ± 3620 cells/μL; p < 0.001). Considering the ICM threshold, polyethylene wear showed the highest proportion of WBC counts above 3000 cells/μL among the indications for aseptic revision (60% [25 of 42]; p < 0.001). Of the periprosthetic conditions, wear-induced synovitis showed the highest proportion beyond the ICM cutoff (60% [50 of 83]; p < 0.001). The mean PMN% for aseptic causes ranged between 28% and 44% without differences among them (p = 0.12). Patients with metallosis had the highest mean PMN% of the periprosthetic conditions investigated (45% ± 25%; p = 0.007). Regarding the ICM threshold, metallosis resulted in the largest proportion of patients with a PMN% above 70% (21% [10 of 47]; p = 0.003), and that for wear-induced synovitis was 6% (5 of 83; p = 0.42) and for osteolysis was 3% (1 of 33; p = 0.51). There were no differences among aseptic loosening, recurrent dislocation, and polyethylene wear in terms of the proportion above 70% among the aseptic revision causes. Using automated cell counting, we found that WBC counts differ widely across indications for aseptic revision THA, and a high proportion of patients who underwent revision THA for aseptic reasons had WBC counts above the commonly used threshold of 3000 cells/μL. However, the PMN% was much less affected in several common indications for aseptic revision THA, making this measure more reliable for interpreting aspiration results using an automated analyzer. Based on the data distributions we observed, manual counting techniques might be considered in particular among patients with polyethylene wear, metal-on-metal bearing surfaces, or suspected metallosis. However, an elevated WBC count alone, observed using an automated analyzer in the context of polyethylene wear, should not be considered to be strongly suggestive of PJI, since that finding occurred so commonly among patients without infection. Level III, diagnostic study.

Sections du résumé

BACKGROUND
Studies have suggested that automated synovial cell counting may overestimate the white blood cell (WBC) count, resulting in false positive tests when evaluating patients for the possibility of periprosthetic joint infection (PJI) after THA. However, associations between WBC counts high enough to mimic PJI in patients whose arthroplasties are not infected but rather are experiencing a variety of aseptic problems-including but not limited to metallosis, polyethylene wear, and recurrent dislocation-have not, to our knowledge, been adequately addressed. In addition, there is a lack of analyses about the polymorphonuclear percentage (PMN%) when assessed by automated analyzers in this context.
QUESTIONS/PURPOSES
In the context of different indications for aseptic revision and different periprosthetic hip pathologic findings, we asked: (1) What were the synovial WBC count levels, and what proportion of values were above the 2018 International Consensus Meeting (ICM) cutoff (3000 cells/μL)? (2) What were the synovial PMN% levels, and what proportion of values were above the 2018 ICM (70%)?
METHODS
We retrospectively studied the preoperative cell count analyses of synovial fluid in patients who underwent revision THA for aseptic reasons at our tertiary referral arthroplasty center between January 2015 and December 2017. We considered all revisions performed on patients during that time potentially eligible, and after prespecified exclusions were applied (exclusions mainly included 15% [197 of 1306] sporadic missing data and 12% [155 of 1306] insufficient synovial fluid obtained in the aspirate), a total of 702 patients undergoing revision THA for aseptic reasons remained for the final analysis. As far as we know, no patients underwent re-revision for PJI at a mean follow-up of 46 ± 11 months, which tends to confirm our impression that indeed these hips did not have PJI. Cell count analyses were conducted using an automated analyzer. Clinical findings, preoperative radiographs, and surgical reports--confirmed by available histologic results--were used to establish diagnoses. We evaluated these hips considering the recommendations of the 2018 ICM (WBC count of 3000 cells/μL and PMN% of 70%) to see what proportion of them would have been characterized as likely having PJI on basis of those cutoff values. The mean WBC count for the entire cohort was 2120 ± 2395 cells/μL. The mean PMN% for the entire cohort was 36% ± 22%.
RESULTS
Compared with aseptic loosening and recurrent dislocation, polyethylene wear had the highest mean WBC count (3817 ± 3711 cells/μL; p < 0.001). Of the investigated periprosthetic conditions, wear-induced synovitis had the highest value (4464 ± 3620 cells/μL; p < 0.001). Considering the ICM threshold, polyethylene wear showed the highest proportion of WBC counts above 3000 cells/μL among the indications for aseptic revision (60% [25 of 42]; p < 0.001). Of the periprosthetic conditions, wear-induced synovitis showed the highest proportion beyond the ICM cutoff (60% [50 of 83]; p < 0.001). The mean PMN% for aseptic causes ranged between 28% and 44% without differences among them (p = 0.12). Patients with metallosis had the highest mean PMN% of the periprosthetic conditions investigated (45% ± 25%; p = 0.007). Regarding the ICM threshold, metallosis resulted in the largest proportion of patients with a PMN% above 70% (21% [10 of 47]; p = 0.003), and that for wear-induced synovitis was 6% (5 of 83; p = 0.42) and for osteolysis was 3% (1 of 33; p = 0.51). There were no differences among aseptic loosening, recurrent dislocation, and polyethylene wear in terms of the proportion above 70% among the aseptic revision causes.
CONCLUSION
Using automated cell counting, we found that WBC counts differ widely across indications for aseptic revision THA, and a high proportion of patients who underwent revision THA for aseptic reasons had WBC counts above the commonly used threshold of 3000 cells/μL. However, the PMN% was much less affected in several common indications for aseptic revision THA, making this measure more reliable for interpreting aspiration results using an automated analyzer. Based on the data distributions we observed, manual counting techniques might be considered in particular among patients with polyethylene wear, metal-on-metal bearing surfaces, or suspected metallosis. However, an elevated WBC count alone, observed using an automated analyzer in the context of polyethylene wear, should not be considered to be strongly suggestive of PJI, since that finding occurred so commonly among patients without infection.
LEVEL OF EVIDENCE
Level III, diagnostic study.

Identifiants

pubmed: 34851871
doi: 10.1097/CORR.0000000000002063
pii: 00003086-202205000-00011
pmc: PMC9007196
doi:

Substances chimiques

Polyethylene 9002-88-4

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

905-914

Commentaires et corrections

Type : CommentIn

Informations de copyright

Copyright © 2021 by the Association of Bone and Joint Surgeons.

Déclaration de conflit d'intérêts

All ICMJE Conflict of Interest Forms for authors and Clinical Orthopaedics and Related Research® editors and board members are on file with the publication and can be viewed on request.

Références

Bäcker HC, Hardt S, Richards JT, Perka C, Janz V. Increased synovial inflammatory markers in aseptic total hip arthroplasty dislocation. J Arthroplasty. 2020;35:1412-1416.
Bauer TW, Bedair H, Screech JD, et al. Hip and knee section, diagnosis, laboratory tests: proceedings of International Consensus on Orthopedic Infections. J Arthroplasty. 2019;34:S351-S359.
Carli AV, Abdelbary H, Ahmadzai N, et al. Diagnostic accuracy of serum, synovial, and tissue testing for chronic periprosthetic joint infection after hip and knee replacements. J Bone Joint Surg Am. 2019;101:635-649.
Chalmers BP, Perry KI, Taunton MJ, Mabry TM, Abdel MP. Diagnosis of adverse local tissue reactions following metal-on-metal hip arthroplasty. Curr Rev Musculoskelet Med. 2016;9:67-74.
Chalmers PN, Sporer SM, Levine BR. Correlation of aspiration results with aseptic loosening in total hip arthroplasty. J Arthroplasty. 2013;28:1671-1676.
Chalmers PN, Walton D, Sporer SM, Levine BR. Evaluation of the role for synovial aspiration in the diagnosis of aseptic loosening after total knee arthroplasty. J Bone Joint Surg Am, 2015;97:1597-1603.
Deirmengian CA, Kazarian GS, Feeley SP, Sizer SC. False-positive automated synovial fluid white blood cell counting is a concern for both hip and knee arthroplasty aspirates. J Arthroplasty, 2020;35:S304-S307.
Hall DJ, Pourzal R, Jacobs JJ. What surgeons need to know about adverse local tissue reaction in total hip arthroplasty. J Arthroplasty. 2020;35:S55-S59.
Higuera CA, Zmistowski B, Malcom T, et al. Synovial fluid cell count for diagnosis of chronic periprosthetic hip infection. J Bone Joint Surg Am. 2017;99:753-759.
Kesteris U, Jonsson K, Robertsson O, Önnerfält R, Wingstrand H. Polyethylene wear and synovitis in total hip arthroplasty. J Arthroplasty. 1999;14:138-143.
Lee YS, Koo KH, Kim HJ, et al. Synovial fluid biomarkers for the diagnosis of periprosthetic joint infection. J Bone Joint Surg Am. 2017;99:2077-2084.
Li AE, Johnson CC, Sneag DB, et al. Frondlike synovitis on MRI and correlation with polyethylene surface damage of total knee arthroplasty. AJR Am J Roentgenol. 2017;209:W231-W237.
Paris A, Nhan T, Cornet E, Perol JP, Malet M, Trousers X. Performance evaluation of the body fluid mode on the platform Sysmex XE-5000 series automated hematology analyzer. Int J Lab Hematol. 2010;32:539-547.
Parvizi J Gehrke T. International Consensus Group on Periprosthetic Joint Infection. Definition of periprosthetic joint infection. J Arthroplasty. 2014;29:1331.
Schwarzkopf R, Carlson EM, Tibbo ME, Josephs L, Scott RD. Synovial fluid differential cell count in wear debris synovitis after total knee replacement. Knee. 2014;21:1023-1028.
Seghezzi M, Buoro S, Manenti B, et al. Optimization of cellular analysis of synovial fluids by optical microscopy and automated count using the Sysmex XN body fluid mode. Clin Chim Acta. 2016;1;462:41-48.
Shohat N, Bauer T, Buttaro M, et al. Hip and knee section, what is the definition of a periprosthetic joint infection (PJI) of the knee and the hip? Can the same criteria be used for both joints? Proceedings of International Consensus on Orthopedic Infections. J Arthroplasty. 2018;34:S325-S327.
Vallés G, García-Cimbrelo E, Vilaboa N. Osteolysis and aseptic loosening: cellular events near the implant. In: Knahr K, ed. Tribology in Total Hip Arthroplasty , Springer; 2011:181-191.
Yi PH, Cross MB, Moric M, et al. Do serologic and synovial tests help diagnose infection in revision hip arthroplasty with metal-on-metal bearings or corrosion? C lin Orthop Relat Res . 2015;473:498-505.

Auteurs

Hussein Abdelaziz (H)

Department of Orthopaedic Surgery, Helios ENDO-Klinik, Hamburg, Germany.

Alaa Aljawabra (A)

Department of Orthopaedic Surgery, Helios ENDO-Klinik, Hamburg, Germany.

Markus Rossmann (M)

Department of Orthopaedic Surgery, Helios ENDO-Klinik, Hamburg, Germany.

Calvin Shum Tien (CS)

Department of Orthopaedic Surgery, Helios ENDO-Klinik, Hamburg, Germany.

Mustafa Citak (M)

Department of Orthopaedic Surgery, Helios ENDO-Klinik, Hamburg, Germany.

Till Orla Klatte (TO)

Department of Trauma-, Hand-, and Reconstructive Surgery, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.

Thorsten Gehrke (T)

Department of Orthopaedic Surgery, Helios ENDO-Klinik, Hamburg, Germany.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH