Accuracy of Reduction Depths of Tooth Preparation for Porcelain Laminate Veneers Assisted by Different Tooth Preparation Guides: An In Vitro Study.
Porcelain laminate veneers (PLVs)
accuracy
surgical guides
tooth preparation
Journal
Journal of prosthodontics : official journal of the American College of Prosthodontists
ISSN: 1532-849X
Titre abrégé: J Prosthodont
Pays: United States
ID NLM: 9301275
Informations de publication
Date de publication:
Aug 2022
Aug 2022
Historique:
accepted:
20
11
2021
pubmed:
4
12
2021
medline:
24
8
2022
entrez:
3
12
2021
Statut:
ppublish
Résumé
To evaluate the accuracy (trueness and precision) of reduction depths of guided veneer preparation assisted by four tooth preparation guides. Fifty resin artificial teeth were randomly divided into five groups (n = 10): a freehand group (F), silicone guide group (S), thermoplastic guide group (T), 3D printed uniform guide group (D), and 3D printed auto-stop guide group (A). A preparation for a window veneer on the maxillary right central incisor was performed by two surgeons who used tooth preparation guides for assistance. The maxillary right central incisors were scanned before and after the preparation. The reduction depths were measured in the cervical, middle, and incisal thirds of the prepared surface, and depth maps were created using Geomagic Control X software. The accuracy of the reduction depths at each third was evaluated using both trueness and precision values. The trueness of the reduction depths was determined by calculating the mean absolute differences (MADs) compared to the planning depth, and precision was determined by the standard deviation (SD). The collected data were statistically analyzed using one-way ANOVA and the least significant difference test (α = 0.05). The MAD ± SD values of the reduction depths in the cervical-third region in groups F, S, T, D, and A were 0.19 ± 0.04, 0.12 ± 0.03, 0.09 ± 0.02, 0.07 ± 0.02, and 0.05 ± 0.01 mm, respectively. In the middle-third region, the MAD ± SD values of groups F-A were 0.19 ± 0.05, 0.13 ± 0.02, 0.09 ± 0.01, 0.06 ± 0.01, and 0.05 ± 0.01 mm. In the incisal-third region, the MAD ± SD values were 0.27 ± 0.05, 0.16 ± 0.04, 0.11 ± 0.03, 0.07 ± 0.01, and 0.05 ± 0.01 mm, respectively. Significant differences in trueness and precision values were found across different groups (F = 45.378, p = 0.000), where group F showed higher MADs than the other 4 groups (p = 0.000), and the highest MADs were detected in group S among the 4 groups in all regions (p = 0.000). Group T showed significantly higher MADs than groups D (P = 0.008) and A (p = 0.001), except in the cervical-third region, where no significant difference was observed between groups T and D (p = 0.077). There was no significant difference between groups D and A (p = 0.148). The deviation map showed significant differences among groups (F = 15.963, p = 0.000), group T presented less deviation than group F (p = 0.000) and group S (p = 0.027) and showed more deviation than group A (p = 0.007). Tooth preparation guides provided more accuracy for veneer preparation than freehand preparation. Among the 4 guides, the 3D printed auto-stop guide presented the lowest absolute difference (0.05 mm) and the silicone guide showed the highest absolute difference of preparation (0.12-0.16 mm).
Substances chimiques
Silicones
0
Dental Porcelain
12001-21-7
Types de publication
Journal Article
Langues
eng
Pagination
593-600Informations de copyright
© 2021 by the American College of Prosthodontists.
Références
Burke FJ: Survival rates for porcelain laminate veneers with special reference to the effect of preparation in dentin: a literature review. J Esthet Restor Dent 2012;24:257-265
Edelhoff D, Sorensen JA: Tooth structure removal associated with various preparation designs for anterior teeth. J Prosthet Dent 2002;87:503-509
Farias-Neto A, de Medeiros FCD, Vilanova L, et al.: Tooth preparation for ceramic veneers: when less is more. Int J Esthet Dent 2019;14:156-164
Ozturk E, Bolay S: Survival of porcelain laminate veneers with different degrees of dentin exposure: 2-year clinical results. J Adhes Dent 2014;16:481-489
Silva BPD, Stanley K, Gardee J: Laminate veneers: preplanning and treatment using digital guided tooth preparation. J Esthet Restor Dent 2020;32:150-160
Preston JD: Rational approach to tooth preparation for ceramo-metal restorations. Dent Clin North Am 1977;21:683-698
Brunton PA, Aminian A, Wilson NH: Tooth preparation techniques for porcelain laminate veneers. Br Dent J 2000;189:260-262
Yu H, Zhao Y, Li J, et al.: Minimal invasive microscopic tooth preparation in esthetic restoration: a specialist consensus. Int J Oral Sci 2019;11:31
Magne P, Douglas WH: Additive contour of porcelain veneers: a key element in enamel preservation, adhesion, and esthetics for aging dentition. J Adhes Dent 1999;1:81-92
Magne P: Immediate dentin sealing: a fundamental procedure for indirect bonded restorations. J Esthet Restor Dent 2005;17:144-154; discussion 155
Magne P, Belser UC: Novel porcelain laminate preparation approach driven by a diagnostic mock-up. J Esthet Restor Dent 2004;16:7-16; discussion 17-18
Gao J, Li J, Liu C, et al.: A stereolithographic template for computer-assisted teeth preparation in dental esthetic ceramic veneer treatment. J Esthet Restor Dent 2020
Aminian A, Brunton PA: A comparison of the depths produced using three different tooth preparation techniques. J Prosthet Dent 2003;89:19-22
Cho SH, Nagy WW: Customized occlusal reduction guide made from a thermoplastic sheet. J Prosthet Dent 2015;114:307-308
Oh WS, Saglik B, May KB: Tooth reduction guide using silicone registration material along with vacuum-formed thermoplastic matrix. J Prosthodont 2010;19:81-83
Cherukara GP, Seymour KG, Zou L, et al.: Geographic distribution of porcelain veneer preparation depth with various clinical techniques. J Prosthet Dent 2003;89:544-550
Cho SH, Nagy WW: Labial reduction guide for laminate veneer preparation. J Prosthet Dent 2015;114:490-492
Li ZY, Bai HF, Zhao YJ, et al: 3D Evaluation of accuracy of tooth preparation for laminate veneers assisted by rigid constraint guides printed by selective laser melting. Chin J Dent Res 2020;23:183-189
Ge C, Green CC, Sederstrom DA, et al: Effect of tooth substrate and porcelain thickness on porcelain veneer failure loads in vitro. J Prosthet Dent 2018;120:85-91
Lin TM, Liu PR, Ramp LC, et al: Fracture resistance and marginal discrepancy of porcelain laminate veneers influenced by preparation design and restorative material in vitro. J Dent 2012;40:202-209
Cattoni F, Teté G, Calloni AM, et al: Milled versus moulded mock-ups based on the superimposition of 3D meshes from digital oral impressions: a comparative in vitro study in the aesthetic area. BMC Oral Health 2019;19:230. https://doi.org/10.1186/s12903-019-0922-2
Park SH, Piedra-Cascon W, Zandinejad A, et al: Digitally created 3-piece additive manufactured index for direct esthetic treatment. J Prosthodont 2020;29:436-442
Revilla-Leon M, Fountain J, Piedra-Cascon W, et al: Silicone additive manufactured indices performed from a virtual diagnostic waxing for direct composite diastema closure combined with resin infiltration technique on white spot lesions: a case report. J Prosthodont 2019;28:855-860
Liu R, Xie C, Sun M, et al: Guided removal of a fractured fiber post and immediate restoration with a digitally prefabricated titanium post-and-core and zirconia crown: a clinical report. J Prosthet Dent 2021
Sá TCM, de Carvalho MFF, de Sá JCM, et al: Esthetic rehabilitation of anterior teeth with different thicknesses of porcelain laminate veneers: an 8-year follow-up clinical evaluation. Eur J Dent 2018;12:590-593
Braganca GF, Vilela ABF, Soares PBF, et al: Influence of ceramic veneer thickness and antagonist on impact stresses during dental trauma with and without a mouthguard assessed with finite element analysis. Dent Traumatol 2021;37:215-222
Blunck U, Fischer S, Hajtó J, et al: Ceramic laminate veneers: effect of preparation design and ceramic thickness on fracture resistance and marginal quality in vitro. Clin Oral Investig 2020;24:2745-2754. https://doi.org/10.1007/s00784-019-03136-z
Liu C, Guo J, Gao J, et al: Computer-assisted tooth preparation template and predesigned restoration: a digital workflow. Int J Comput Dent 2020;23:1-12