Continuous cardiac thermometry via simultaneous catheter tracking and undersampled radial golden angle acquisition for radiofrequency ablation monitoring.


Journal

Scientific reports
ISSN: 2045-2322
Titre abrégé: Sci Rep
Pays: England
ID NLM: 101563288

Informations de publication

Date de publication:
07 03 2022
Historique:
received: 06 09 2021
accepted: 24 01 2022
entrez: 8 3 2022
pubmed: 9 3 2022
medline: 21 4 2022
Statut: epublish

Résumé

The complexity of the MRI protocol is one of the factors limiting the clinical adoption of MR temperature mapping for real-time monitoring of cardiac ablation procedures and a push-button solution would ease its use. Continuous gradient echo golden angle radial acquisition combined with intra-scan motion correction and undersampled temperature determination could be a robust and more user-friendly alternative than the ultrafast GRE-EPI sequence which suffers from sensitivity to magnetic field susceptibility artifacts and requires ECG-gating. The goal of this proof-of-concept work is to establish the temperature uncertainty as well as the spatial and temporal resolutions achievable in an Agar-gel phantom and in vivo using this method. GRE radial golden angle acquisitions were used to monitor RF ablations in a phantom and in vivo in two sheep hearts with different slice orientations. In each case, 2D rigid motion correction based on catheter micro-coil signal, tracking its motion, was performed and its impact on the temperature imaging was assessed. The temperature uncertainty was determined for three spatial resolutions (1 × 1 × 3 mm

Identifiants

pubmed: 35256627
doi: 10.1038/s41598-022-06927-9
pii: 10.1038/s41598-022-06927-9
pmc: PMC8901729
doi:

Types de publication

Journal Article Research Support, Non-U.S. Gov't

Langues

eng

Sous-ensembles de citation

IM

Pagination

4006

Informations de copyright

© 2022. The Author(s).

Références

Cronin, E. M. et al. 2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias. EP Eur. 21, 1143–1144 (2019).
Njeim, M., Desjardins, B. & Bogun, F. Multimodality imaging for guiding EP ablation procedures. JACC Cardiovasc. Imaging 9, 873–886 (2016).
pubmed: 27388666 doi: 10.1016/j.jcmg.2016.03.009
Enriquez, A. et al. Use of intracardiac echocardiography in interventional cardiology. Circulation 137, 2278–2294 (2018).
pubmed: 29784681 doi: 10.1161/CIRCULATIONAHA.117.031343
Kolandaivelu, A. Role of cardiac imaging (CT/MRI) before and after RF catheter ablation in patients with atrial fibrillation. J. Atr. Fibrillation 5, 54–65 (2012).
Obeng-Gyimah, E. & Nazarian, S. Advancements in imaging for atrial fibrillation ablation: Is there a potential to improve procedural outcomes? J. Innov. Card. Rhythm Manage. 11, 4172–4178 (2020).
doi: 10.19102/icrm.2020.110701
Yamashita, S. et al. Image integration to guide catheter ablation in scar-related ventricular tachycardia. J. Cardiovasc. Electrophysiol. 27, 699–708 (2016).
pubmed: 26918883 doi: 10.1111/jce.12963
Kumar, S. et al. Better lesion creation and assessment during catheter ablation. J. Atr. Fibrillation 8, 62 (2015).
Sommer, P. et al. Feasibility of real-time magnetic resonance imaging-guided electrophysiology studies in humans. EP Eur. 15, 101–108 (2013).
Kolandaivelu, A. et al. Noninvasive assessment of tissue heating during cardiac radiofrequency ablation using MRI thermography. Circ. Arrhythmia Electrophysiol. 3, 521–529 (2010).
doi: 10.1161/CIRCEP.110.942433
Nordbeck, P. et al. Cardiac catheter ablation under real-time magnetic resonance guidance. Eur. Heart J. 33, 1977–1977 (2012).
pubmed: 22677138 pmcid: 3409423 doi: 10.1093/eurheartj/ehs139
Paetsch, I. et al. Clinical workflow and applicability of electrophysiological cardiovascular magnetic resonance-guided radiofrequency ablation of isthmus-dependent atrial flutter. Eur. Hear. J. Cardiovasc. Imaging 20, 147–156 (2019).
doi: 10.1093/ehjci/jey143
White, J. A. et al. Utility of cardiovascular magnetic resonance in identifying substrate for malignant ventricular arrhythmias. Circ. Cardiovasc. Imaging 5, 12–20 (2012).
pubmed: 22038987 doi: 10.1161/CIRCIMAGING.111.966085
Mahida, S. et al. Cardiac imaging in patients with ventricular tachycardia. Circulation 136, 2491–2507 (2017).
pubmed: 29255125 doi: 10.1161/CIRCULATIONAHA.117.029349
Wright, G. A., Krahn, P. R. P. & Glover, B. M. Magnetic resonance imaging a new gold standard for radiofrequency ablation assessment in ventricular arrhythmia treatments? JACC Clin. Electrophysiol. 5, 101–103 (2019).
pubmed: 30678773 doi: 10.1016/j.jacep.2018.11.014
Celik, H. et al. Intrinsic contrast for characterization of acute radiofrequency ablation lesions. Circ. Arrhythmia Electrophysiol. 7, 718–727 (2014).
doi: 10.1161/CIRCEP.113.001163
Haaf, P. et al. Cardiac T1 mapping and extracellular volume (ECV) in clinical practice: A comprehensive review. J. Cardiovasc. Magn. Reson. 18, 1–12 (2016).
Luetkens, J. A. et al. Incremental value of quantitative CMR including parametric mapping for the diagnosis of acute myocarditis. Eur. Heart J. Cardiovasc. Imaging 17, 154–161 (2016).
pubmed: 26476398 doi: 10.1093/ehjci/jev246
Krahn, P. R. P. et al. Cardiovascular magnetic resonance guided ablation and intra-procedural visualization of evolving radiofrequency lesions in the left ventricle. J. Cardiovasc. Magn. Reson. 20, 1–12 (2018).
doi: 10.1186/s12968-018-0437-z
Toupin, S. et al. Feasibility of real-time MR thermal dose mapping for predicting radiofrequency ablation outcome in the myocardium in vivo. J. Cardiovasc. Magn. Reson. 19, 1–12 (2017).
doi: 10.1186/s12968-017-0323-0
Winter, L. et al. Magnetic resonance thermometry: Methodology, pitfalls and practical solutions. Int. J. Hyperth. 32, 63–75 (2016).
doi: 10.3109/02656736.2015.1108462
Feddersen, T. V., Hernandez-Tamames, J. A., Franckena, M., van Rhoon, G. C. & Paulides, M. M. Clinical performance and future potential of magnetic resonance thermometry in hyperthermia. Cancers (Basel) 13, 31 (2020).
doi: 10.3390/cancers13010031
de Senneville, B. D. et al. Feasibility of fast MR-thermometry during cardiac radiofrequency ablation. NMR Biomed. 25, 556–562 (2012).
pubmed: 22553824 doi: 10.1002/nbm.1771
Schneider, W. G., Bernstein, H. J. & Pople, J. A. Proton magnetic resonance chemical shift of free (gaseous) and associated (liquid) hydride molecules. J. Chem. Phys. 28, 601–607 (1958).
doi: 10.1063/1.1744199
Ishihara, Y. et al. A precise and fast temperature mapping using water proton chemical shift. Magn. Reson. Med. 34, 814–823 (1995).
pubmed: 8598808 doi: 10.1002/mrm.1910340606
Poorter, J. D. et al. Noninvasive MRI thermometry with the proton resonance frequency (PRF) method: In vivo results in human muscle. Magn. Reson. Med. 33, 74–81 (1995).
pubmed: 7891538 doi: 10.1002/mrm.1910330111
Rieke, V. & Pauly, K. B. MR thermometry. J. Magn. Reson. Imaging 27, 376–390 (2008).
pubmed: 18219673 pmcid: 2780364 doi: 10.1002/jmri.21265
McDannold, N. Quantitative MRI-based temperature mapping based on the proton resonant frequency shift: Review of validation studies. Int. J. Hyperth. 21, 533–546 (2005).
doi: 10.1080/02656730500096073
Odéen, H. & Parker, D. L. Magnetic resonance thermometry and its biological applications—Physical principles and practical considerations. Prog. Nucl. Magn. Reson. Spectrosc. 110, 34–61 (2019).
pubmed: 30803693 pmcid: 6662927 doi: 10.1016/j.pnmrs.2019.01.003
Peters, R. D., Hinks, R. S. & Henkelman, R. M. Ex vivo tissue-type independence in proton-resonance frequency shift MR thermometry. Magn. Reson. Med. 40, 454–459 (1998).
pubmed: 9727949 doi: 10.1002/mrm.1910400316
Vogl, T. J. et al. Malignant liver tumors treated with MR imaging-guided laser-induced thermotherapy: Technique and prospective results. Radiology 196, 257–265 (1995).
pubmed: 7540310 doi: 10.1148/radiology.196.1.7540310
Stafford, R. J. & Hazle, J. D. Magnetic resonance temperature imaging for focused ultrasound surgery: A review. Top. Magn. Reson. Imaging 17, 153–163 (2006).
pubmed: 17414072 doi: 10.1097/RMR.0b013e3180377bc3
Gorny, K. R. et al. Practical implementation of robust MR-thermometry during clinical MR-guided microwave ablations in the liver at 1.5 T. Phys. Med. 67, 91–99 (2019).
pubmed: 31704392 doi: 10.1016/j.ejmp.2019.10.020
Ozenne, V. et al. Improved cardiac magnetic resonance thermometry and dosimetry for monitoring lesion formation during catheter ablation. Magn. Reson. Med. 77, 673–683 (2017).
pubmed: 26899165 doi: 10.1002/mrm.26158
Ozenne, V. et al. Assessment of left ventricle magnetic resonance temperature stability in patients in the presence of arrhythmias. NMR Biomed. 32, 1–16 (2019).
doi: 10.1002/nbm.4160
Mukherjee, R. K. et al. Epicardial electroanatomical mapping, radiofrequency ablation, and lesion imaging in the porcine left ventricle under real-time magnetic resonance imaging guidance—An in vivo feasibility study. EP Eur. 20, f254–f262 (2018).
Rasche, V., Holz, D., Köhler, J., Proksa, R. & Röschmann, P. Catheter tracking using continuous radial MRI. Magn. Reson. Med. 37, 963–968 (1997).
pubmed: 9178250 doi: 10.1002/mrm.1910370623
Gaur, P. & Grissom, W. A. Accelerated MRI thermometry by direct estimation of temperature from undersampled k-space data. Magn. Reson. Med. 73, 1914–1925 (2015).
pubmed: 24935053 doi: 10.1002/mrm.25327
Grissom, W. A. et al. Hybrid referenceless and multibaseline subtraction MR thermometry for monitoring thermal therapies in moving organs. Med. Phys. 37, 5014–5026 (2010).
pubmed: 20964221 pmcid: 2945742 doi: 10.1118/1.3475943
Knoll, F., Schwarzl, A., Diwoky, C. & Sodickson, D. gpuNUFFT—An open-source GPU library for 3D gridding with direct matlab interface. In ISMRM, 4297 (2014).
Hansen, M. S. & Sørensen, T. S. Gadgetron: An open source framework for medical image reconstruction. Magn. Reson. Med. 69, 1768–1776 (2013).
pubmed: 22791598 doi: 10.1002/mrm.24389
Inati, S. J. et al. ISMRM Raw data format: A proposed standard for MRI raw datasets. Magn. Reson. Med. 77, 411–421 (2017).
pubmed: 26822475 doi: 10.1002/mrm.26089
Qin, L. et al. Prospective motion correction using tracking coils. Magn. Reson. Med. 69, 749–759 (2013).
pubmed: 22565377 doi: 10.1002/mrm.24310
King, S. B., Varosi, S. M. & Duensing, G. R. Eigenmode analysis for understanding phased array coils and their limits. Concepts Magn. Reson. B Magn. Reson. Eng. 29B, 42–49 (2006).
doi: 10.1002/cmr.b.20054
Funai, A. K., Fessler, J. A., Yeo, D. T. B., Olafsson, V. T. & Noll, D. C. Regularized field map estimation in MRI. IEEE Trans. Med. Imaging 27, 1484–1494 (2008).
pubmed: 18815100 pmcid: 2856353 doi: 10.1109/TMI.2008.923956
De Zwart, J. A., Van Gelderen, P., Kelly, D. J. & Moonen, C. T. W. Fast magnetic-resonance temperature imaging. J. Magn. Reson. Ser. B 112, 86–90 (1996).
doi: 10.1006/jmrb.1996.0115
Wang, F. et al. Fast temperature estimation from undersampled k-space with fully-sampled center for MR guided microwave ablation. Magn. Reson. Imaging 34, 1171–1180 (2016).
pubmed: 27211258 doi: 10.1016/j.mri.2016.05.003
Glover, G. H. & Pauly, J. M. Projection reconstruction techniques for reduction of motion effects in MRI. Magn. Reson. Med. 28, 275–289 (1992).
pubmed: 1461126 doi: 10.1002/mrm.1910280209
Vaillant, G., Prieto, C., Kolbitsch, C., Penney, G. & Schaeffter, T. Retrospective rigid motion correction in k-space for segmented radial MRI. IEEE Trans. Med. Imaging 33, 1–10 (2014).
pubmed: 23782798 doi: 10.1109/TMI.2013.2268898
Roy, C. W. et al. Motion compensated whole-heart coronary cardiovascular magnetic resonance angiography using focused navigation (fNAV). J. Cardiovasc. Magn. Reson. 23, 1–17 (2021).
doi: 10.1186/s12968-021-00717-4
Stehning, C., Börnert, P., Nehrke, K., Eggers, H. & Stuber, M. Free-breathing whole-heart coronary MRA with 3D radial SSFP and self-navigated image reconstruction. Magn. Reson. Med. 54, 476–480 (2005).
pubmed: 16032682 doi: 10.1002/mrm.20557
Sørensen, T. S., Atkinson, D., Schaeffter, T. & Hansen, M. S. Real-time reconstruction of sensitivity encoded radial magnetic resonance imaging using a graphics processing unit. IEEE Trans. Med. Imaging 28, 1974–1985 (2009).
pubmed: 19628452 doi: 10.1109/TMI.2009.2027118
Contijoch, F. et al. Self-gated MRI of multiple beat morphologies in the presence of arrhythmias. Magn. Reson. Med. 78, 678–688 (2017).
pubmed: 27579717 doi: 10.1002/mrm.26381
Chava, R., Assis, F., Herzka, D. & Kolandaivelu, A. Segmented radial cardiac MRI during arrhythmia using retrospective electrocardiogram and respiratory gating. Magn. Reson. Med. 81, 1726–1738 (2019).
pubmed: 30362588 doi: 10.1002/mrm.27533
Cheng, J. Y. et al. Nonrigid motion correction in 3D using autofocusing withlocalized linear translations. Magn. Reson. Med. 68, 1785–1797 (2012).
pubmed: 22307933 pmcid: 3376676 doi: 10.1002/mrm.24189
De Zwart, J. A., Vimeux, F. C., Delalande, C., Canioni, P. & Moonen, C. T. W. Fast lipid-suppressed MR temperature mapping with echo-shifted gradient- echo imaging and spectral-spatial excitation. Magn. Reson. Med. 42, 53–59 (1999).
pubmed: 10398950 doi: 10.1002/(SICI)1522-2594(199907)42:1<53::AID-MRM9>3.0.CO;2-S
Moonen, C. T. W., Liu, G., Gelderen, P. V. & Sobering, G. A fast gradient-recalled MRI technique with increased sensitivity to dynamic susceptibility effects. Magn. Reson. Med. 26, 184–189 (1992).
pubmed: 1625564 doi: 10.1002/mrm.1910260118
Thomas, H. M. et al. Magnetic resonance compatible and susceptibility-matched apparatus and method for MR imaging & spectroscopy (2011).

Auteurs

Maxime Yon (M)

IHU Liryc, Electrophysiology and Heart Modeling Institute, Hopital Xavier Arnozan, Foundation Bordeaux Université, Avenue du Haut Lévêque, 33604, Pessac Cedex, France. maxime.yon@gmail.com.
Centre de Recherche Cardio-Thoracique de Bordeaux Inserm, U1045, Université de Bordeaux, 33000, Bordeaux, France. maxime.yon@gmail.com.
INSERM, Centre de recherche Cardio-Thoracique de Bordeaux, U1045, F-33000, Bordeaux, France. maxime.yon@gmail.com.

Marylène Delcey (M)

IHU Liryc, Electrophysiology and Heart Modeling Institute, Hopital Xavier Arnozan, Foundation Bordeaux Université, Avenue du Haut Lévêque, 33604, Pessac Cedex, France.
Centre de Recherche Cardio-Thoracique de Bordeaux Inserm, U1045, Université de Bordeaux, 33000, Bordeaux, France.
INSERM, Centre de recherche Cardio-Thoracique de Bordeaux, U1045, F-33000, Bordeaux, France.

Pierre Bour (P)

IHU Liryc, Electrophysiology and Heart Modeling Institute, Hopital Xavier Arnozan, Foundation Bordeaux Université, Avenue du Haut Lévêque, 33604, Pessac Cedex, France.
Centre de Recherche Cardio-Thoracique de Bordeaux Inserm, U1045, Université de Bordeaux, 33000, Bordeaux, France.
INSERM, Centre de recherche Cardio-Thoracique de Bordeaux, U1045, F-33000, Bordeaux, France.

William Grissom (W)

Department of Biomedical Engineering, Vanderbilt University, 5824 Stevenson Center, Nashville, TN, 37235, USA.

Bruno Quesson (B)

IHU Liryc, Electrophysiology and Heart Modeling Institute, Hopital Xavier Arnozan, Foundation Bordeaux Université, Avenue du Haut Lévêque, 33604, Pessac Cedex, France.
Centre de Recherche Cardio-Thoracique de Bordeaux Inserm, U1045, Université de Bordeaux, 33000, Bordeaux, France.
INSERM, Centre de recherche Cardio-Thoracique de Bordeaux, U1045, F-33000, Bordeaux, France.

Valéry Ozenne (V)

IHU Liryc, Electrophysiology and Heart Modeling Institute, Hopital Xavier Arnozan, Foundation Bordeaux Université, Avenue du Haut Lévêque, 33604, Pessac Cedex, France.
Centre de Recherche Cardio-Thoracique de Bordeaux Inserm, U1045, Université de Bordeaux, 33000, Bordeaux, France.
INSERM, Centre de recherche Cardio-Thoracique de Bordeaux, U1045, F-33000, Bordeaux, France.

Articles similaires

Humans Ketamine Propofol Pulmonary Atelectasis Female
Robotic Surgical Procedures Animals Humans Telemedicine Models, Animal

Odour generalisation and detection dog training.

Lyn Caldicott, Thomas W Pike, Helen E Zulch et al.
1.00
Animals Odorants Dogs Generalization, Psychological Smell
Animals TOR Serine-Threonine Kinases Colorectal Neoplasms Colitis Mice

Classifications MeSH