Advances in multiscale image processing and its effects on image quality in skeletal radiography.


Journal

Scientific reports
ISSN: 2045-2322
Titre abrégé: Sci Rep
Pays: England
ID NLM: 101563288

Informations de publication

Date de publication:
18 03 2022
Historique:
received: 06 10 2021
accepted: 09 03 2022
entrez: 19 3 2022
pubmed: 20 3 2022
medline: 6 5 2022
Statut: epublish

Résumé

Multi-frequency processing (MFP) leads to enhanced image quality (IQ) of radiographs. This study is to determine the effect of third generation MFP (M3) on IQ in comparison to standard second-generation MFP (M2). 20 cadavers were examined and post-processing of radiographs was performed with both M2 and M3. Three readers blinded to the MFP used for each image independently compared corresponding image pairs according to overall IQ and depiction of bony structures and soft tissue (+ 2: notably better > 0: equal > - 2: notably worse). A significant deviation of the median grade from grade 0 (equal) (p < 0.01) for each evaluator A, B and C speaks against an equal image quality of M2- and M3-images. M3-images were categorized with better grades (+ 1, + 2) in 87.7% for overall image quality, in 90.4% for soft tissue and 81.8% for bony structures. M3 images showed significant higher averaged SNR and CNR for all investigated lower extremities than that of M2 images (0.031 < p < 0.049). The newest generation of MFP leads to significantly better depiction of anatomical structures and overall image quality than in images processed with the preceding generation of MFP. This provides increased diagnostic accuracy and further decreased radiation exposure.

Identifiants

pubmed: 35304544
doi: 10.1038/s41598-022-08699-8
pii: 10.1038/s41598-022-08699-8
pmc: PMC8933435
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

4726

Informations de copyright

© 2022. The Author(s).

Références

Sci Rep. 2021 Apr 8;11(1):7701
pubmed: 33833315
Med Phys. 2000 Jan;27(1):56-65
pubmed: 10659738
IEEE Trans Med Imaging. 2002 Apr;21(4):343-53
pubmed: 12022622
Br J Radiol. 2007 Sep;80(957):724-30
pubmed: 17709364
Eur J Radiol. 2009 Nov;72(2):194-201
pubmed: 19695809
Pediatr Radiol. 2012 Sep;42(9):1112-8
pubmed: 22526280
Br J Radiol. 2012 Jul;85(1015):e330-8
pubmed: 21937611
Pediatr Radiol. 2016 Oct;46(11):1606-13
pubmed: 27488507
Invest Radiol. 1998 Jan;33(1):33-8
pubmed: 9438507
Radiographics. 2007 May-Jun;27(3):675-86
pubmed: 17495286
J Med Radiat Sci. 2014 Sep;61(3):176-90
pubmed: 26229654
Clin Radiol. 2000 Aug;55(8):615-21
pubmed: 10964733
Dentomaxillofac Radiol. 2010 May;39(4):207-15
pubmed: 20395461
J Thorac Imaging. 2003 Jul;18(3):148-64
pubmed: 12867812
Radiat Prot Dosimetry. 2005;114(1-3):11-25
pubmed: 15933076
J Med Radiat Sci. 2014 Jun;61(2):112-8
pubmed: 26229645
Eur Radiol. 1997 Feb 21;7(11):73-82
pubmed: 9089116
Radiology. 2009 Jan;250(1):152-60
pubmed: 19001150
J Digit Imaging. 1997 Aug;10(3 Suppl 1):185-9
pubmed: 9268878
Radiat Prot Dosimetry. 2016 Jun;169(1-4):221-4
pubmed: 26541187
Eur J Radiol. 2009 Nov;72(2):202-8
pubmed: 19628349

Auteurs

Susan Notohamiprodjo (S)

Department of Nuclear Medicine, Klinikum rechts der Isar, Technical University of Munich, Ismaninger Str. 22, 81675, Munich, Germany. s.notohamiprodjo@tum.de.

K M Roeper (KM)

Department of Ophthalmology, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany.

F G Mueck (FG)

Department of Radiology, HELIOS Klinikum München West, Munich, Germany.

D Maxien (D)

Radiologisches Zentrum München, Munich, Germany.

F Wanninger (F)

Agfa-Gevaert HealthCare GmbH, Munich, Germany.

B Hoberg (B)

Agfa HealthCare Germany GmbH, Bonn, Germany.

L Verstreepen (L)

Agfa NV, Mortsel, Belgium.

K M Treitl (KM)

Department of Radiology, University Hospital of Munich, LMU Munich, Munich, Germany.

F Fischer (F)

Institute of Forensic Medicine, LMU Munich, Munich, Germany.

O Peschel (O)

Institute of Forensic Medicine, LMU Munich, Munich, Germany.

S Wirth (S)

Institute of Radiology, Schwarzwald-Baar Klinikum, Villingen-Schwenningen, Germany.

Articles similaires

Failed radial head arthroplasty treated by removal of the implant.

Juan Ameztoy Gallego, Blanca Diez Sanchez, Afonso Vaquero-Picado et al.
1.00
Humans Male Female Middle Aged Range of Motion, Articular
1.00
Humans Magnetic Resonance Imaging Brain Infant, Newborn Infant, Premature
Cephalometry Humans Anatomic Landmarks Software Internet
Humans Shoulder Fractures Tomography, X-Ray Computed Neural Networks, Computer Female

Classifications MeSH