Evaluation of Monomer Elution and Surface Roughness of a Polymer-Infiltrated Ceramic Network CAD-CAM Material After Er,Cr:YSGG Laser-assisted Tooth Bleaching.
Journal
Operative dentistry
ISSN: 1559-2863
Titre abrégé: Oper Dent
Pays: United States
ID NLM: 7605679
Informations de publication
Date de publication:
01 Sep 2021
01 Sep 2021
Historique:
accepted:
07
11
2020
entrez:
29
4
2022
pubmed:
30
4
2022
medline:
4
5
2022
Statut:
ppublish
Résumé
The aim of this in vitro study was to examine the effect of Er,Cr:YSGG laser-assisted tooth bleaching treatment on the elution of monomers and surface roughness of a hybrid computer-aided design-computer-aided manufacturing (CAD-CAM) material, and to compare it with a resin composite for direct restorations. Forty specimens of a hybrid CAD-CAM material (Enamic) and forty of a conventional resin composite (Tetric) were fabricated and randomly divided into four groups (n=10). Half of the specimens of each material were stored in distilled water and the other half in artificial saliva for 7 days. At the end of this period, the storage medium was analyzed by high-performance liquid chromatography (HPLC), and the surface roughness parameters of the specimens were evaluated by optical imaging noncontact interferometric profilometry. Afterwards, half of the specimens of each tested material received a conventional in-office tooth bleaching treatment and the other half an Er,Cr:YSGG laser-assisted bleaching treatment, and then they were again incubated in distilled water and artificial saliva for an additional 7-day time period. At the end of this period, the effect of the bleaching treatments on elution of monomers and surface roughness of the tested materials was evaluated. Bisphenol A (BPA), urethane dimethacrylate (UDMA), triethylene glycol dimethacrylate (TEGDMA), and bisphenol A-glycidyl dimethacrylate (BisGMA) were eluted from the conventional resin composite into both the solutions tested. Only TEGDMA was eluted from the hybrid CAD-CAM material. However, no statistically significant differences were found among the surface roughness parameters of both materials. Both the conventional and Er,Cr:YSGG laser-assisted tooth bleaching treatments affected the monomer elution from the composite resin. However, there were no statistically significant differences (p<0.05) between the treatments. According to the results of this study, tooth bleaching with Er,Cr:YSGG laser or conventional technique is safe, even if the bleaching agent comes in contact with hybrid CAD-CAM restorations.
Identifiants
pubmed: 35486503
pii: 480861
doi: 10.2341/20-158-L
doi:
Substances chimiques
Polymers
0
Saliva, Artificial
0
Water
059QF0KO0R
Types de publication
Journal Article
Langues
eng
Pagination
E171-E184Informations de copyright
©Operative Dentistry, 2021.