Balloon- vs Self-Expanding Valve Systems for Failed Small Surgical Aortic Valve Bioprostheses.
insufficiency
stenosis
transcatheter aortic valve implantation
valve-in-valve
Journal
Journal of the American College of Cardiology
ISSN: 1558-3597
Titre abrégé: J Am Coll Cardiol
Pays: United States
ID NLM: 8301365
Informations de publication
Date de publication:
16 08 2022
16 08 2022
Historique:
received:
15
04
2022
revised:
10
05
2022
accepted:
11
05
2022
pubmed:
22
5
2022
medline:
16
8
2022
entrez:
21
5
2022
Statut:
ppublish
Résumé
Data comparing valve systems in the valve-in-valve transcatheter aortic valve replacement (ViV-TAVR) field have been obtained from retrospective studies. The purpose of this study was to compare the hemodynamic results between the balloon-expandable valve (BEV) SAPIEN (3/ULTRA, Edwards Lifesciences) and self-expanding valve (SEV) Evolut (R/PRO/PRO+, Medtronic) in ViV-TAVR. Patients with a failed small (≤23 mm) surgical valve were randomized to receive a BEV or an SEV. The primary endpoint was valve hemodynamics (maximal/mean residual gradients, severe prosthesis patient mismatch [PPM], or moderate-severe aortic regurgitation) at 30 days as evaluated by Doppler echocardiography. A total of 102 patients were randomized, and of these, 98 patients finally underwent a ViV-TAVR procedure (BEV: n = 46, SEV: n = 52). The procedure was successful in all cases, with no differences in clinical outcomes at 30 days between groups (no death or stroke events). Patients in the SEV group exhibited lower mean and maximal transvalvular gradient values (15 ± 8 mm Hg vs 23 ± 8 mm Hg; P ˂ 0.001; 28 ± 16 mm Hg vs 40 ± 13 mm Hg, P ˂ 0.001), and a tendency toward a lower rate of severe PPM (44% vs 64%; P = 0.07). There were no cases of moderate-severe aortic regurgitation. In total, 55 consecutive patients (SEV: n = 27; BEV: n = 28) underwent invasive valve hemodynamic evaluation during the procedure, with no differences in mean and peak transvalvular gradients between both groups (P = 0.41 and P = 0.70, respectively). In patients with small failed aortic bioprostheses, ViV-TAVR with an SEV was associated with improved valve hemodynamics as evaluated by echocardiography. There were no differences between groups in intraprocedural invasive valve hemodynamics and 30-day clinical outcomes (Comparison of the Balloon-Expandable Edwards Valve and Self-Expandable CoreValve Evolut R or Evolut PRO System for the Treatment of Small, Severely Dysfunctional Surgical Aortic Bioprostheses. The 'LYTEN' Trial; NCT03520101).
Sections du résumé
BACKGROUND
Data comparing valve systems in the valve-in-valve transcatheter aortic valve replacement (ViV-TAVR) field have been obtained from retrospective studies.
OBJECTIVES
The purpose of this study was to compare the hemodynamic results between the balloon-expandable valve (BEV) SAPIEN (3/ULTRA, Edwards Lifesciences) and self-expanding valve (SEV) Evolut (R/PRO/PRO+, Medtronic) in ViV-TAVR.
METHODS
Patients with a failed small (≤23 mm) surgical valve were randomized to receive a BEV or an SEV. The primary endpoint was valve hemodynamics (maximal/mean residual gradients, severe prosthesis patient mismatch [PPM], or moderate-severe aortic regurgitation) at 30 days as evaluated by Doppler echocardiography.
RESULTS
A total of 102 patients were randomized, and of these, 98 patients finally underwent a ViV-TAVR procedure (BEV: n = 46, SEV: n = 52). The procedure was successful in all cases, with no differences in clinical outcomes at 30 days between groups (no death or stroke events). Patients in the SEV group exhibited lower mean and maximal transvalvular gradient values (15 ± 8 mm Hg vs 23 ± 8 mm Hg; P ˂ 0.001; 28 ± 16 mm Hg vs 40 ± 13 mm Hg, P ˂ 0.001), and a tendency toward a lower rate of severe PPM (44% vs 64%; P = 0.07). There were no cases of moderate-severe aortic regurgitation. In total, 55 consecutive patients (SEV: n = 27; BEV: n = 28) underwent invasive valve hemodynamic evaluation during the procedure, with no differences in mean and peak transvalvular gradients between both groups (P = 0.41 and P = 0.70, respectively).
CONCLUSIONS
In patients with small failed aortic bioprostheses, ViV-TAVR with an SEV was associated with improved valve hemodynamics as evaluated by echocardiography. There were no differences between groups in intraprocedural invasive valve hemodynamics and 30-day clinical outcomes (Comparison of the Balloon-Expandable Edwards Valve and Self-Expandable CoreValve Evolut R or Evolut PRO System for the Treatment of Small, Severely Dysfunctional Surgical Aortic Bioprostheses. The 'LYTEN' Trial; NCT03520101).
Identifiants
pubmed: 35597385
pii: S0735-1097(22)04978-6
doi: 10.1016/j.jacc.2022.05.005
pii:
doi:
Banques de données
ClinicalTrials.gov
['NCT03520101']
Types de publication
Journal Article
Randomized Controlled Trial
Research Support, Non-U.S. Gov't
Langues
eng
Sous-ensembles de citation
IM
Pagination
681-693Commentaires et corrections
Type : CommentIn
Type : ErratumIn
Informations de copyright
Copyright © 2022 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Déclaration de conflit d'intérêts
Funding Support and Author Disclosures Dr Rodés-Cabau holds the Research Chair “Fondation Famille Jacques Larivière” for the Development of Structural Heart Disease Interventions (Laval University); and has received institutional research grants from and is consultant for Edwards Lifesciences and Medtronic. Dr Abbas has received research grants and consulting fees from Edwards Lifesciences. Dr Nombela-Franco holds a research grant (INT19/00040 and CM21/00091) from the Spanish Ministry of Science and Inovation (Instituto de Salud Carlos III); and has received consulting fees from Edwards Lifesciences. Dr Conradi is a member of the Advisory Board of Medtronic, Abbott, JenaValve, and Neovase; and has received consulting fees from Edwards Lifesciences, Boston Scientific, New Valve Technology, and MicroInterventions. Dr Pibarot has received research grants from Edwards Lifesciences and Medtronic; and has received consulting fees from Edwards Lifesciences. All other authors have reported that they have no relationships relevant to the contents of this paper to disclose.