Effect of multiple firings on surface roughness and flexural strength of CAD-CAM ceramics.


Journal

The Journal of prosthetic dentistry
ISSN: 1097-6841
Titre abrégé: J Prosthet Dent
Pays: United States
ID NLM: 0376364

Informations de publication

Date de publication:
Aug 2022
Historique:
received: 05 11 2021
revised: 23 05 2022
accepted: 24 05 2022
pubmed: 6 7 2022
medline: 31 8 2022
entrez: 5 7 2022
Statut: ppublish

Résumé

Knowledge on the effect of multiple firings on surface roughness and the flexural strength of different types of monolithic computer-aided design and computer-aided manufacturing (CAD-CAM) ceramics is limited. The purpose of this in vitro study was to evaluate the effect of multiple firings on the surface roughness and flexural strength of 4 different CAD-CAM ceramics after thermocycling. Four different CAD-CAM ceramics (Lava All Zirconia 3-mol yttria tetragonal zirconia polycrystal [3-YTZP] [Z], VITA SUPRINITY [S], IPS e.max CAD [EX], IPS Empress CAD [E]) (n=33) were wet-sectioned to form rectangular 18×4×1.2-mm specimens. After glaze application, the specimens were divided into 3 subgroups according to the number of firings (1, 2, and 4) (n=11). The specimens were thermocycled (10 000 cycles), and surface roughness and flexural strength values were measured (n=10). One additional specimen from each group was analyzed by using scanning electron microscopy (SEM). Data were analyzed by 2-way analysis of variance (ANOVA) and the Tukey honestly significance difference (HSD) test (α=.05). According to the 2-way ANOVA, the material, number of firings, and the interaction between the material and number of firings affected the surface roughness (P<.001). For flexural strength, material (P<.001) and number of firings (P<.039) were found significant. Multiple firings (2 or 4 firings) affected the surface roughness of E (P<.001). Regardless of the number of firings, the Z material had the highest flexural strength (P<.001). Four firings affected the flexural strength values only for the Z material (P≤.005). CAD-CAM ceramic type affected the surface roughness and flexural strength values. The surface roughness of E was lower when fired 2 or 4 times than when fired once. The flexural strength of Z was lower when fired 4 times than when fired once.

Identifiants

pubmed: 35788273
pii: S0022-3913(22)00348-1
doi: 10.1016/j.prosdent.2022.05.021
pii:
doi:

Substances chimiques

Dental Porcelain 12001-21-7

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

216.e1-216.e8

Informations de copyright

Copyright © 2022 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Auteurs

Meryem Gülce Subaşı (MG)

Associate Professor, Department of Prosthodontics, Kutahya Saglik Bilimleri University, Faculty of Dentistry, Kütahya, Turkey.

Gülce Çakmak (G)

Senior Research Associate, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland. Electronic address: guelce.cakmak@zmk.unibe.ch.

Murat Sert (M)

Assistant Professor, Department of Medical Laboratory Techniques, Ankara Yildirim Beyazit University, Ankara, Turkey.

Burak Yilmaz (B)

Associate Professor, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Associate Professor, Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland; Adjunct Professor, Division of Restorative and Prosthetic Dentistry, The Ohio State University University College of Dentistry, Columbus, Ohio.

Articles similaires

Hemiarthroplasty in young patients.

Hazimah Mahmud, Dong Wang, Andra Topan-Rat et al.
1.00
Humans Male Hemiarthroplasty Middle Aged Aged
Silicon Dioxide Water Hot Temperature Compressive Strength X-Ray Diffraction
1.00
Sudan Archaeology Humans History, Ancient Animals
Nitriles Tensile Strength Materials Testing Gloves, Protective Product Packaging

Classifications MeSH