30 years of ocular proton therapy, the Nice view.
Customization
Eye/ocular
Melanoma
Mélanome
Proton therapy
Protonthérapie
Radiothérapie
Tumeur
Tumor
Œil/oculaire
Journal
Cancer radiotherapie : journal de la Societe francaise de radiotherapie oncologique
ISSN: 1769-6658
Titre abrégé: Cancer Radiother
Pays: France
ID NLM: 9711272
Informations de publication
Date de publication:
Nov 2022
Nov 2022
Historique:
received:
29
11
2021
accepted:
15
03
2022
pubmed:
9
7
2022
medline:
9
11
2022
entrez:
8
7
2022
Statut:
ppublish
Résumé
Radiotherapy with protons (PT) is a standard treatment of ocular tumors. It achieves excellent tumor control, limited toxicities, and the preservation of important functional outcomes, such as vision. Although PT may appear as one homogenous technique, it can be performed using dedicated ocular passive scattering PT or, increasingly, Pencil Beam Scanning (PBS), both with various degrees of patient-oriented customization. MEDICYC PT facility of Nice are detailed with respect to their technical, dosimetric, microdosimetric and radiobiological, patient and tumor-customization process of PT planning and delivery that are key. 6684 patients have been treated for ocular tumors (1991-2020). Machine characteristics (accelerator, beam line, beam monitoring) allow efficient proton extraction, high dose rate, sharp lateral and distal penumbrae, and limited stray radiation in comparison to beam energy reduction and subsequent straggling with high-energy PBS PT. Patient preparation before PT includes customized setup and image-guidance, CT-based planning, and ocular PT software modelling of the patient eye with integration of beam modifiers. Clinical reports have shown excellent tumor control rates (∼95%), vision preservation and limited toxicity rates (papillopathy, retinopathy, neovascular glaucoma, dry eye, madarosis, cataract). Although demanding, dedicated ocular PT has proven its efficiency in achieving excellent tumor control, OAR sparing and patient radioprotection. It is therefore worth adaptations of the equipments and practice. Some of these adaptations can be transferred to other PT centers and should be acknowledeged when using non-PT options.
Identifiants
pubmed: 35803860
pii: S1278-3218(22)00091-9
doi: 10.1016/j.canrad.2022.03.004
pii:
doi:
Substances chimiques
Protons
0
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
1016-1026Informations de copyright
Copyright © 2022 Société française de radiothérapie oncologique (SFRO). Published by Elsevier Masson SAS. All rights reserved.