UK NEQAS Haematology pilot scheme: Reticulocyte haemoglobin content quantitation.
iron deficiency
laboratory haematology
quality assurance
reticulocyte haemoglobin content
Journal
International journal of laboratory hematology
ISSN: 1751-553X
Titre abrégé: Int J Lab Hematol
Pays: England
ID NLM: 101300213
Informations de publication
Date de publication:
Dec 2022
Dec 2022
Historique:
received:
20
05
2022
accepted:
08
08
2022
pubmed:
4
9
2022
medline:
19
11
2022
entrez:
3
9
2022
Statut:
ppublish
Résumé
Established parameters for the investigation of suspected iron deficiency have recognized limitations that affect their sensitivity and specificity. Reticulocyte haemoglobin content (RHC) is an early biomarker of iron deficiency or restriction, which also demonstrates response to iron therapy. RHC parameters are offered on all major automated haematology analysers. There is no external quality assessment (EQA) for RHC in the UK, restricting its wider clinical application. The UK National External Quality Assessment Scheme (UKNEQAS) for Haematology has completed a pilot study on the use of stabilized blood for RHC EQA. Blood was obtained from two JAK2 V617F mutation-positive, polycythaemia vera patients undergoing regular venesection, and from a healthy volunteer donor. Aliquots of each donation were distributed to users of Abbott, Horiba, Siemens and Sysmex automated analysers for RHC analysis on days 1, 3, 5 and 7. Results were received from 20 laboratories using four different platforms. The daily mean and standard deviation (SD) were calculated for each aliquot, by day of analysis and platform. With RHC there was no significant within-platform difference (p > 0.5) between testing days, although there were statistically significant differences (p < 0.001) between different platforms. The greatest difference was seen between Abbott MCHr and Horiba RhCc (-6.14 ± 1.25 pg). Despite inter-platform differences, it was possible to define iron deficient, borderline, and normal cut-offs to classify 95% of results correctly. The results demonstrate that it is possible to provide RHC EQA material using UKNEQAS standard procedures. The results are clinically relevant but indicate a requirement for inter-user comparison.
Substances chimiques
Hemoglobins
0
Iron
E1UOL152H7
Types de publication
Journal Article
Review
Langues
eng
Sous-ensembles de citation
IM
Pagination
1088-1093Informations de copyright
© 2022 John Wiley & Sons Ltd.
Références
Fletcher A, Forbes A, Svenson N, Thomas DW. Guideline for the laboratory diagnosis of iron deficiency in adults (excluding pregnancy) and children. Br J Haematol. 2022;196:523-529.
Snook J, Bhala N, Beales ILP, et al. British Society of Gastroenternology guidelines for the management of iron deficiency anaemia in adults. Gut. 2021;0:1-22.
Thomas DW, Hinchliffe RF, Briggs C, Macdougall IC, Littlewood T, Cavill I. Guideline for the laboratory diagnosis of functional iron deficiency. Br J Haematol. 2013;161:639-648.
Pavord S, Daru J, Prasannan N, et al. UKguidelines on the management of iron deficiency in pregnancy. Br J Haematol. 2020;188:819-830.
Ratcliffe LEK, Thomas W, Glen J, et al. Diagnosis and Management of Iron Deficiency in CKD: a summary of the NICE guideline recommendations and their rationale. Am J Kidney Dis. 2016;67:548-558.
D'Onofrio G, Chirillo R, Zini G, Caenaro G, Tommasi M, Micciulli G. Simultaneous measurement of reticulocyte and red blood cell indices in healthy subjects and patients with microcytic and macrocytic anemia. Blood. 1995;85:818-823.
Hinchliffe RF, Mahon A, Thomas W, et al. Results of a prepilot study of potential test material for the external quality assessment of reticulocyte haemoglobin. Int J Lab Hematol. 2016;38:e86-e88.
Reardon DM, Mack D, Warner B. A whole blood control for blood count analysers and a source material for an EQA scheme. Med Lab Sci. 1991;48:19-26.
Canals C, Remacha AF, Sarda MP, Piazuelo JM, Royo MT, Romero MA. Clinical utility of the new Sysmex XE 2100 parameter-reticulocyte haemoglobin equivalent-in the diagnosis of anaemia. Haematologica. 2005;90:1133-1134.
Ng EHY, Leung JHW, Lau YS, Ma ESK. Evaluation of the new red cell parameters on Beckman coulter DxH800 in distinguishing iron deficiency anaemia from thalassaemia trait. Int J Lab Hematol. 2015;37:199-207.