Non-Invasive Stable Sensory Feedback for Closed-Loop Control of Hand Prosthesis.


Journal

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference
ISSN: 2694-0604
Titre abrégé: Annu Int Conf IEEE Eng Med Biol Soc
Pays: United States
ID NLM: 101763872

Informations de publication

Date de publication:
07 2022
Historique:
entrez: 10 9 2022
pubmed: 11 9 2022
medline: 14 9 2022
Statut: ppublish

Résumé

The absence of somatotopic sensory feedback limits the function of conventional prosthetic hands. In this study, we integrated a non-invasive sensory feedback system into a commercial Bebionic hand with new customized surface stimulation electrodes. Multiple modalities of tactile and hand aperture sensory information were conveyed to the amputee via the technique of evoked tactile sensation (ETS) elicited at projected finger map (PFM) of residual limb and an additional electrotactile stimulation in the ipsilateral upper arm. A previously developed anti-stimulus artifact module was used to remove the stimulus artifact from surface electromyographic (sEMG) signals, and the filtered sEMG envelops controlled the speed of open/close of the Bebionic hand. The Ag/AgCl surface stimulation electrode in 10-mm diameter was specially designed to fit the restricted PFM areas for stable perception. We evaluated the alternating-current (AC) impedance magnitude of this electrode stimulated over 12 hours. The perceptual and upper thresholds in pulse-width over 200 days at PFM areas were recorded to assess the stability of the non-invasive sensory neural interface. The efficacy of multi-modality feedback for identification of physical properties of objects was also assessed. Results showed that the AC impedance of customized surface stimulation electrode was stable over 12 hours of stimulation. The perceptual and upper thresholds were stable over 200 days. This non-invasive sensory feedback enabled a forearm amputee to identify the compliance and length of grasped objects with an accuracy of 100 %. Results illustrated that the multi-modality sensory feedback system provided stable and sufficient sensory information for perceptual discrimination of physical features of grasped objects. Clinical Relevance- This study demonstrated a promising and novel way to restore stable sensory feedback non-invasively for commercial hand prostheses.

Identifiants

pubmed: 36086109
doi: 10.1109/EMBC48229.2022.9871682
doi:

Types de publication

Journal Article Research Support, Non-U.S. Gov't

Langues

eng

Sous-ensembles de citation

IM

Pagination

2344-2347

Auteurs

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH