A Real-Time Energy Monitoring System for an MRI Hybrid Ablation System.


Journal

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference
ISSN: 2694-0604
Titre abrégé: Annu Int Conf IEEE Eng Med Biol Soc
Pays: United States
ID NLM: 101763872

Informations de publication

Date de publication:
07 2022
Historique:
entrez: 10 9 2022
pubmed: 11 9 2022
medline: 14 9 2022
Statut: ppublish

Résumé

The MRI hybrid ablation system is an approach to use the MR (magnetic resonance) scanner's radiofrequency amplifier itself as power source for ablation. Hereby, an electrode is connected to the MR internal radiofrequency amplifier. An average RF power is provided through a train of short RF pulses, which is sufficient to thermally destroy tissue. However, ablation with too high power values can cause tissue carbonizations, thus impeding the ablation procedure. Therefore, monitoring of the energy and the power absorbed inside the tissue is necessary. For this purpose, a measurement system was designed to measure the energy applied to the tissue when using the concept of an MRI hybrid ablation system. The system consists of a dual-directional coupler, RF-to-RMS sensors, and a microcontroller. The gradient calculation of the measured energy curve provides information about the absorbed RF power in the tissue. Validation measurements of the system were performed and compared with measurements from the MR-internal power measurement system. The energy monitoring system was also tested in an ablation experiment with ex-vivo animal tissue using the MRI hybrid ablation system. The measurements showed that the applied RF power can be monitored in real-time. It has been shown that the mean RF power absorbed in the patient decreased during an ablation procedure due to an occurring impedance mismatch and tissue changes. In further work, the influence of the monitoring system on the quality of the MR images should be investigated. Clinical relevance- This paper demonstrates an energy monitoring system for an RF ablation system, which can be used inside an MR environment.

Identifiants

pubmed: 36086647
doi: 10.1109/EMBC48229.2022.9870997
doi:

Types de publication

Journal Article Research Support, Non-U.S. Gov't

Langues

eng

Sous-ensembles de citation

IM

Pagination

5016-5020

Auteurs

Articles similaires

Humans Ketamine Propofol Pulmonary Atelectasis Female
Robotic Surgical Procedures Animals Humans Telemedicine Models, Animal

Odour generalisation and detection dog training.

Lyn Caldicott, Thomas W Pike, Helen E Zulch et al.
1.00
Animals Odorants Dogs Generalization, Psychological Smell
Animals TOR Serine-Threonine Kinases Colorectal Neoplasms Colitis Mice

Classifications MeSH