The effects of manufacturing technologies on the surface accuracy of CAD-CAM occlusal splints.

3D-printing additive manufacturing digital workflow milling subtractive manufacturing

Journal

Journal of prosthodontics : official journal of the American College of Prosthodontists
ISSN: 1532-849X
Titre abrégé: J Prosthodont
Pays: United States
ID NLM: 9301275

Informations de publication

Date de publication:
Oct 2023
Historique:
received: 12 05 2022
accepted: 01 10 2022
medline: 23 10 2023
pubmed: 14 10 2022
entrez: 13 10 2022
Statut: ppublish

Résumé

To investigate the effects of the manufacturing technologies on the surface (cameo and intaglio) accuracy (trueness and precision) of computer-aided design and computer-aided manufacturing (CAD-CAM) occlusal splints. The digital design of the master occlusal splint was designed in a CAD software program. Six groups (n = 10) were tested in this study, including Group 1 - Milling (Wax), Group 2 - Heat-polymerizing, Group 3 - Milling (M series), Group 4 - Milling (DWX-51/52D), Group 5 - 3D-printing (Cares P30), and Group 6 - 3D-printing (M2). The study samples were placed in a scanning jig fabricated from putty silicone and Type III dental stone. The study samples were then scanned with a laboratory scanner at the intaglio and cameo surfaces, and the scanned files were exported in standard tessellation language (STL) file format. The master occlusal splint STL file, was used as a reference to compare with all scanned samples at the intaglio and cameo surfaces in a surface matching software program. Root mean square (RMS, measured in mm, absolute value) values were calculated by the software for accuracy comparisons. Group means were used as the representation of trueness, and the standard deviation for each group was calculated as a measure of precision. Color maps were recorded to visualize the areas of deviation between study samples and the master occlusal splint file. The data were normalized and transformed to rank scores, and one-way ANOVA was used to test for the differences between the groups. Pairwise comparisons were made between different groups. Fishers least square differences were used to account for the family-wise error rate. A 5% significance level was used for all the tests. The null hypotheses were rejected. The manufacturing technologies significantly affected the trueness of occlusal splints at both intaglio and cameo surfaces (p < 0.001). At the cameo surfaces, Group 1 - Milling (Wax) (0.03 ± 0.02 mm), Group 3 - Milling (M series) (0.04 ± 0.01 mm), and Group 4 - Milling (DWX-51/52D) (0.04 ± 0.01 mm) had the smallest mean RMS values and highest trueness. Group 3 had the smallest standard deviation and highest precision among all groups (p < 0.001, except p = 0.005 when compared with Group 2). Group 5 had the largest standard deviation and lowest precision among all groups (p < 0.001). At the intaglio surfaces, Group 1 - Milling (Wax) (0.06 ± 0.01 mm) had the smallest RMS values and highest trueness among all groups (p < 0.001), and Group 2 - Heat-polymerizing (0.20 ± 0.03 mm) and Group 5 - 3D-printing (Cares P30) (0.15 ± 0.05 mm) had significantly larger mean RMS and standard deviation values than all other groups (p < 0.001), with lowest trueness and precision. In the color maps, Group 2 - Heat-polymerizing and Group 5 - 3D-printing (Cares P30) showed the most discrepancies with yellow and red (positive discrepancies) in most areas, and Group 1 - Milling (Wax) showed the best and most uniform surface matching with the most area in green. The manufacturing technologies significantly affected the trueness and precision of occlusal splints at both intaglio and cameo surfaces. The 5-axis milling units and industrial-level CLIP 3D-printer could be considered to achieve surface accuracy of occlusal splints.

Identifiants

pubmed: 36227731
doi: 10.1111/jopr.13610
doi:

Types de publication

Journal Article

Langues

eng

Pagination

697-705

Informations de copyright

© 2022 by the American College of Prosthodontists.

Références

Berli C, Thieringer FM, Sharma N, Müller JA, Dedem P, Fischer J, et al. Comparing the mechanical properties of pressed, milled, and 3D-printed resins for occlusal devices. J Prosthet Dent. 2020;124:780-6.
Caminiti M, Lou T. Clear Aligner Orthognathic Splints. J Oral Maxillofac Surg. 2019;77:1071. e1-e8.
Capp NJ. Occlusion and splint therapy. Br Dent J. 1999;186:217-22.
Chu SA, Suvinen TI, Clement JG, Reade PC. The effect of interocclusal appliances on temporomandibular joints as assessed by 3D reconstruction of MRI scans. Aust Dent J. 2001;46:18-23.
Edelhoff D, Schweiger J, Prandtner O, Trimpl J, Stimmelmayr M, Güth JF. CAD-CAM splints for the functional and esthetic evaluation of newly defined occlusal dimensions. Quintessence Int 2017;48:181-91.
Fang JJ, Liu JK, Wu TC, Lee JW, Kuo TH. Complex facial deformity reconstruction with a surgical guide incorporating a built-in occlusal stent as the positioning reference. J Craniofac Surg. 2013;24:e260-5.
Shaheen E, Sun Y, Jacobs R, Politis C. Three-dimensional printed final occlusal splint for orthognathic surgery: design and validation. Int J Oral Maxillofac Surg. 2017;46:67-71.
Zinser M, Zoeller J. Computer-designed splints for surgical transfer of 3D orthognathic planning. Facial Plast .Surg 2015;31:474-90.
Gibbs CH, Mahan PE, Lundeen HC, Brehnan K, Walsh EK, Sinkewiz SL, et al. Occlusal forces during chewing-influences of biting strength and food consistency. J Prosthet Dent. 1981;46:561-7.
Salmi M, Paloheimo KS, Tuomi J, Ingman T, Mäkitie A. A digital process for additive manufacturing of occlusal splints: a clinical pilot study. J R Soc Interface. 2013;10:20130203. doi:10.1098/rsif.2013.0203.
Turner KA, Missirlian DM. Restoration of the extremely worn dentition. J Prosthet Dent. 1984;52:467-74.
Nelson SJ. Principles of stabilization bite splint therapy. Dent Clin North Am. 1995;39:403-21.
Prpic V, Slacanin I, Schauperl Z, Catic A, Dulcic N, Cimic S. A study of the flexural strength and surface hardness of different materials and technologies for occlusal device fabrication. J Prosthet Dent. 2019;121:955-9.
Lauren M, McIntyre F. A new computer-assisted method for design and fabrication of occlusal splints. Am J Orthod Dentofacial Orthop. 2008;133(4 Suppl):S130-5.
Reymus M Reinhard H, Andreas K. Accuracy of CAD/CAM-fabricated bite splints: milling vs 3D printing. Clin Oral Investig. 2020;24:4607-15.
Jeong YG, Lee WS, Lee KB. Accuracy evaluation of dental models manufactured by CAD/CAM milling method and 3D printing method. J Adv Prosthodont. 2018;10:245-51.
Lee S, Hong SJ, Paek J, Pae A, Kwon KR, Noh K. Comparing accuracy of denture bases fabricated by injection molding, CAD/CAM milling, and rapid prototyping method. J Adv Prosthodont. 2019;11:55-64.
Lutz AM, Hampe R, Roos M, Lümkemann N, Eichberger M, Stawarczyk B. Fracture resistance and 2-body wear of 3-dimensional-printed occlusal devices. J Prosthet Dent. 2019;121:166-72.
Reymus M, Stawarczyk B. In vitro study on the influence of postpolymerization and aging on the Martens parameters of 3D-printed occlusal devices. J Prosthet Dent. 2021;125:817-23.
Ye N, Wu T, Dong T, Yuan L, Fang B, Xia L. Precision of 3D-printed splints with different dental model offsets. Am J Orthod Dentofacial Orthop. 2019;155:733-8.
Koch GK, Gallucci GO, Lee SJ. Accuracy in the digital workflow: from data acquisition to the digitally milled cast. J Prosthet Dent. 2016;115:749-54.
Gibreel M, Perea-Lowery L, Vallittu PK, Lassila L. Characterization of occlusal splint materials: CAD-CAM versus conventional resins. J Mech Behav Biomed Mater. 2021;124:104813
Lo Giudice A, Ronsivalle V, Pedullà E, Rugeri M, Leonardi R. Digitally programmed (CAD) offset values for prototyped occlusal splints (CAM): assessment of appliance-fitting using surface-based superimposition and deviation analysis. Int J Comput Dent. 2021;24:53-63.
Grymak A, Aarts JM, Ma S, Waddell JN, Choi JJE. Comparison of hardness and polishability of various occlusal splint materials. J Mech Behav Biomed Mater. 2021;115:104270
Grymak A, Waddell JN, Aarts JM, Ma S, Choi JJE. Evaluation of wear behaviour of various occlusal splint materials and manufacturing processes. J Mech Behav Biomed Mater. 2022;126:105053
Rubayo DD, Phasuk K, Vickery JM, Morton D, Lin WS. Influences of build angle on the accuracy, printing time, and material consumption of additively manufactured surgical templates. J Prosthet Dent. 2021;126:658-63.
Rungrojwittayakul O, Kan JY, Shiozaki K, Swamidass RS, Goodacre BJ, Goodacre CJ, et al. Accuracy of 3D printed models created by two technologies of printers with different designs of model base. J Prosthodont. 2020;29:124-8.
Carbon Inc Website: https://www.carbon3d.com/resources/dls-101/value-of-subscription-for-3d-printer/. Accessed 5/12/22

Auteurs

Ahmet Orgev (A)

Department of Restorative Dentistry, University at Buffalo School of Dental Medicine, Buffalo, New York.

John A Levon (JA)

Department of Prosthodontics, Indiana University School of Dentistry, Indianapolis, Indiana.

Tien-Min G Chu (TG)

Department of Biomedical Sciences and Comprehensive Care, Indiana University School of Dentistry, Indianapolis, Indiana.

Dean Morton (D)

Department of Prosthodontics, Indiana University School of Dentistry, Indianapolis, Indiana.

Wei-Shao Lin (WS)

Department of Prosthodontics, Indiana University School of Dentistry, Indianapolis, Indiana.

Articles similaires

Selecting optimal software code descriptors-The case of Java.

Yegor Bugayenko, Zamira Kholmatova, Artem Kruglov et al.
1.00
Software Algorithms Programming Languages

Exploring blood-brain barrier passage using atomic weighted vector and machine learning.

Yoan Martínez-López, Paulina Phoobane, Yanaima Jauriga et al.
1.00
Blood-Brain Barrier Machine Learning Humans Support Vector Machine Software
Cephalometry Humans Anatomic Landmarks Software Internet
Humans Algorithms Software Artificial Intelligence Computer Simulation

Classifications MeSH