Mitral regurgitation (MR) is frequently observed in patients undergoing left ventricular assist device implantation. We investigated the impact of preoperative MR on left ventricular assist device patients. A retrospective propensity score-matched analysis of adult patients enrolled in the EUROMACS registry between 1 January 2011 and 30 November 2021 was performed. Patients were divided into 2 groups according to the grade of preoperative MR: none-to-mild (MR 0-II) or moderate-to-severe (MR III-IV). Following 1:1 propensity score matching, each group consisted of 914 patients. Incidence of postoperative temporary right ventricular support, reoperation for bleeding and dialysis was similar. MR III-IV demonstrated shorter median intensive care unit stay [14 days (6; 27.8) vs 10 days (5; 22), P = 0.004] and ventilation time [72 h (22, 320) vs 31 h (18, 150), P < 0.001]. Mortality was lower for MR III-IV patients [subdistribution hazard ratio: 0.66, 95% confidence interval (CI): 0.59-0.73, P < 0.001]. The 1-year survival was 68.1% (95% CI: 65.1-71.3%) in MR 0-II and 75% (95% CI: 72.1-78%) in MR III-IV. A lower incidence of total complications [odds ratio (OR): 0.93 (0.89-0.98), P = 0.003] and trend towards a lower risk of neurological dysfunction (subdistribution hazard ratio: 0.79; 95% CI: 0.61-1.01, P = 0.063) and sustained ventricular tachycardia [OR: 0.93 (0.54-1.03), P = 0.074] were demonstrated for MR III-IV. The risk of fatal stroke and pump thrombosis was similar. Moderate-to-severe MR in patients undergoing left ventricular assist device implantation is associated with better mid-term survival and lower incidence of total major adverse events and complications. The incidence of severe postoperative complications including fatal stroke and device thrombosis was similar.
Identifiants
pubmed: 36637204
pii: 6986977
doi: 10.1093/ejcts/ezad013
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Subventions
Organisme : EACTS
Informations de copyright
© The Author(s) 2023. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.