Résumé

To develop an efficient MRI pulse sequence to simultaneously measure multiple parameters that have been shown to correlate with tissue nonviability following thermal therapies. A 3D segmented EPI pulse sequence was used to simultaneously measure proton resonance frequency shift (PRFS) MR thermometry (MRT), T In phantom studies, temperature increases measured with PRFS MRT and increases in T An efficient approach for simultaneous and dynamic measurements of PRSF, T

Identifiants

pubmed: 36656135
doi: 10.1002/mrm.29587
doi:

Substances chimiques

Protons 0

Types de publication

Journal Article Research Support, Non-U.S. Gov't Research Support, N.I.H., Extramural

Langues

eng

Sous-ensembles de citation

IM

Pagination

2171-2185

Subventions

Organisme : NCI NIH HHS
ID : F30 CA228363
Pays : United States
Organisme : NIBIB NIH HHS
ID : R01 EB028316
Pays : United States
Organisme : NIBIB NIH HHS
ID : R03 EB029204
Pays : United States
Organisme : NCI NIH HHS
ID : R37 CA224141
Pays : United States
Organisme : NIH HHS
ID : S10 OD018482
Pays : United States
Organisme : NIBIB NIH HHS
ID : R21 EB033638
Pays : United States

Informations de copyright

© 2023 International Society for Magnetic Resonance in Medicine.

Références

Deckers R, Merckel LG, de Senneville BD, et al. Performance analysis of a dedicated breast MR-HIFU system for tumor ablation in breast cancer patients. Phys Med Biol. 2015;60:5527-5542.
Ghanouni P, Pauly KB, Elias WJ, et al. Transcranial MRI-guided focused ultrasound: a review of the technologic and neurologic applications. Am J Roentgenol. 2015;205:150-159. doi:10.2214/AJR.14.13632
Khanna N, Gandhi D, Steven A, Frenkel V, Melhem ER. Intracranial applications of MR imaging-guided focused ultrasound. Am J Neuroradiol. 2017;38:426-431. doi:10.3174/ajnr.A4902
Jacoby VL, Kohi MP, Poder L, et al. PROMISe trial: a pilot, randomized, placebo-controlled trial of magnetic resonance guided focused ultrasound for uterine fibroids. Fertil Steril. 2016;105:773-780. doi:10.1016/j.fertnstert.2015.11.014
Tay KJ, Cheng CWS, Lau WKO, Khoo J, Thng CH, Kwek JW. Focal therapy for prostate cancer with In-bore MR-guided focused ultrasound: two-year follow-up of a phase I trial-complications and functional outcomes. Radiology. 2017;285:620-628. doi:10.1148/radiol.2017161650
van Breugel JMM, Wijlemans JW, Vaessen HHB, et al. Procedural sedation and analgesia for respiratory-gated MR-HIFU in the liver: a feasibility study. J Ther Ultrasound. 2016;4:1-12. doi:10.1186/s40349-016-0063-x
Wang TR, Dallapiazza R, Elias WJ. Neurological applications of transcranial high intensity focused ultrasound. Int J Hyperthermia. 2015;31:285-291. doi:10.3109/02656736.2015.1007398
Elias WJ, Lipsman N, Ondo WG, et al. A randomized trial of focused ultrasound thalamotomy for essential tremor. N Engl J Med. 2016;375:730-739. doi:10.1056/NEJMoa1600159
Legon W, Sato TF, Opitz A, et al. Transcranial focused ultrasound modulates the activity of primary somatosensory cortex in humans. Nat Neurosci. 2014;17:322-329. doi:10.1038/nn.3620
Yoo SS, Bystritsky A, Lee JH, et al. Focused ultrasound modulates region-specific brain activity. Neuroimage. 2011;56:1267-1275. doi:10.1016/j.neuroimage.2011.02.058
Burgess A, Shah K, Hough O, Hynynen K. Focused ultrasound-mediated drug delivery through the blood-brain barrier. Expert Rev Neurother. 2015;15:477-491. doi:10.1586/14737175.2015.1028369.Focused
Weber-Adrian D, Thévenot E, O'Reilly MA, et al. Gene delivery to the spinal cord using MRI-guided focused ultrasound. Gene Ther. 2015;22:568-577. doi:10.1038/gt.2015.25
Payne AH, Hawryluk GW, Anzai Y, et al. Magnetic resonance imaging-guided focused ultrasound to increase localized blood-spinal cord barrier permeability. Neural Regen Res. 2017;12:2045-2049. doi:10.4103/1673-5374.221162
Thomsen S, Pearce JA. Thermal damage and rate processes in biologic tissues. Optical-Thermal Response of Laser-Irradiated Tissue. Springer; 2010:487-549. doi:10.1007/978-90-481-8831-4_13
Matylevitch NP, Schuschereba ST, Mata JR, et al. Apoptosis and accidental cell death in cultured human keratinocytes after thermal injury. Am J Pathol. 1998;153:567-577. doi:10.1016/S0002-9440(10)65599-X
Chu KF, Dupuy DE. Thermal ablation of tumours: biological mechanisms and advances in therapy. Nat Rev Cancer. 2014;14:199-208. doi:10.1038/nrc3672
Odéen H, Parker DL. Magnetic resonance thermometry and its biological applications-physical principles and practical considerations. Prog Nucl Magn Reson Spectrosc. 2019;110:34-61. doi:10.1016/j.pnmrs.2019.01.003
Sapareto SA, Dewey WC. Thermal dose determination in cancer therapy. Int J Radiat Oncol Biol Phys. 1984;10:787-800.
McDannold HK, Wolf D, Wolf G, Jolesz F. MRI evaluation of thermal ablation of tumors with focused ultrasound. J Magn Reson Imaging. 1998;8:91-100.
Hylton NM. Vascularity assessment of breast lesions with gadolinium-enhanced MR imaging. Magn Reson Imaging Clin N Am. 1999;9:321-332.
Wu F, Chen W-Z, Bai J, et al. Tumor vessel destruction resulting from high-intensity focused ultrasound in patients with solid malignancies. Ultrasound Med Biol. 2002;28:535-542.
Lewa CJ, Majewska Z. Temperature relationships of proton spin-lattice relaxation time T1 in biological tissues. Bull Cancer. 1980;67:525-530.
Cline HE, Hynynen K, Hardy CJ, Watkins RD, Schenck JF, Jolesz FA. MR temperature mapping of focused ultrasound surgery. Magn Reson Med. 1994;31:628-636.
Kuroda KK, Iwabuchi TI, Obara MO, Honda MH. Temperature dependence of relaxation times in proton components of fatty acids. Magn Reson Med Sci. 2011;10:177-183.
Hey S, de Smet M, Stehning C, et al. Simultaneous T1 measurements and proton resonance frequency shift based thermometry using variable flip angles. Magn Reson Med. 2012;67:457-463. doi:10.1002/mrm.22987
Todd N, Diakite M, Payne A, Parker DL. Hybrid proton resonance frequency/T1 technique for simultaneous temperature monitoring in adipose and aqueous tissues. Magn Reson Med. 2013;69:62-70.
Diakite M, Odéen H, Todd N, Payne A, Parker DL. Toward real-time temperature monitoring in fat and aqueous tissue during magnetic resonance-guided high-intensity focused ultrasound using a three-dimensional proton resonance frequency T1 method. Magn Reson Med. 2014;72:178-187. doi:10.1002/mrm.24900
Baron P, Deckers R, Knuttel FM, Bartels LW. T1 and T2 temperature dependence of female human breast adipose tissue at 1.5 T: groundwork for monitoring thermal therapies in the breast. NMR Biomed. 2015;28:1463-1470. doi:10.1002/nbm.3410
Dickinson RJ, Hall AS, Hind AJ, Young IR. Measurement of changes in tissue temperature using MR imaging. J Comput Assist Tomogr. 1986;10:468-472.
Hall AS, Prior MV, Hand JW, Young IR, Dickinson RJ. Observation by MR imaging of in vivo temperature changes induced by radio frequency hyperthermia. J Comput Assist Tomogr. 1990;14:430-436.
Baron P, Ries M, Deckers R, et al. In vivo T2 -based MR thermometry in adipose tissue layers for high-intensity focused ultrasound near-field monitoring. Magn Reson Med. 2014;72:1057-1064.
Diakite M, Payne A, Todd N, Parker DL. Irreversible change in the T1 temperature dependence with thermal dose using the proton resonance frequency-T1 technique. Magn Reson Med. 2013;69:1122-1130.
Peller M, Reinl HM, Weigel A, Meininger M, Issels RD, Reiser M. T1 relaxation time at 0.2 Tesla for monitoring regional hyperthermia: feasibility study in muscle and adipose tissue. Magn Reson Med. 2002;47:1194-1201. doi:10.1002/mrm.10155
Peller M, Kurze V, Loeffler R, et al. Hyperthermia induces T1 relaxation and blood flow changes in tumors. A MRI thermometry study in vivo. Magn Reson Imaging. 2003;21:545-551. doi:10.1016/S0730-725X(03)00070-5
Graham SJ, Stanisz GJ, Kecojevic A, Bronskill MJ, Henkelman RM. Analysis of changes in MR properties of tissues after heat treatment. Magn Reson Med. 1999;42:1061-1071.
Fried MP, Morrison PR, Hushek SG, Kernahan GA, Jolesz FA. Dynamic T1-weighted magnetic resonance imaging of interstitial laser photocoagulation in the liver: observations on in vivo temperature sensitivity. Lasers Surg Med. 1996;18:410-419.
Hectors SJCG, Jacobs I, Strijkers GJ, Nicolay K. Multiparametric MRI analysis for the identification of high intensity focused ultrasound-treated tumor tissue. PLoS One. 2014;9:e99936. doi:10.1371/journal.pone.0099936
Damianou C, Hynynen K. The effect of various physical parameters on the size and shape of necrosed tissue volume during ultrasound surgery. J Acoust Soc Am. 1994;95:1641-1649.
Dewhirst MW, Viglianti BL, Lora-Michiels M, Hanson M, Hoopes PJ. Basic principles of thermal dosimetry and thermal thresholds for tissue damage from hyperthermia. Int J Hyperthermia. 2003;19:267-294. doi:10.1080/0265673031000119006
McDannold NJ, King RL, Jolesz F, Hynynen KH. Usefulness of MR imaging-derived thermometry and dosimetry in determining the threshold for tissue damage induced by thermal surgery in rabbits. Radiology. 2000;216:517-523. doi:10.1148/radiology.216.2.r00au42517
Yarmolenko PS, Moon EJ, Landon C, et al. Thresholds for thermal damage to normal tissues: an update. Int J Hyperthermia. 2011;27:320-343. doi:10.3109/02656736.2010.534527
Bitton RR, Webb TD, Pauly KB, Ghanouni P. Improving thermal dose accuracy in magnetic resonance-guided focused ultrasound surgery: long-term thermometry using a prior baseline as a reference. J Magn Reson Imaging. 2015;43:181-189. doi:10.1002/jmri.24978
Quesson B, Laurent C, Maclair G, et al. Real-time volumetric MRI thermometry of focused ultrasound ablation in vivo: a feasibility study in pig liver and kidney. NMR Biomed. 2011;24:145-153. doi:10.1002/nbm.1563
Kirkham APS, Emberton M, Hoh IM, Illing RO, Freeman AA, Allen C. MR imaging of prostate after treatment with high-intensity focused ultrasound. Radiology. 2008;246:833-844. doi:10.1148/radiol.2463062080
Hundt W, Yuh EL, Steinbach S, Bednarski MD. Effect of continuous high intensity focused ultrasound in a squamous cell carcinoma tumor model compared to muscle tissue evaluated by MRI, histology, and gene expression. Technol Cancer Res Treat. 2009;8:85-98. doi:10.1177/153303460900800201
Zhang Y, Zhao J, Guo D, Zhong W, Ran L. Evaluation of short-term response of high intensity focused ultrasound ablation for primary hepatic carcinoma: utility of contrast-enhanced MRI and diffusion-weighted imaging. Eur J Radiol. 2011;79:347-352. doi:10.1016/j.ejrad.2010.06.039
Bohris C, Jenne JW, Rastert R, et al. MR monitoring of focused ultrasound surgery in a breast tissue model in vivo. Magn Reson Imaging. 2001;19:167-175.
Curiel L, Souchon R, Rouvière O, Gelet A, Chapelon JY. Elastography for the follow-up of high-intensity focused ultrasound prostate cancer treatment: initial comparison with MRI. Ultrasound Med Biol. 2005;31:1461-1468. doi:10.1016/j.ultrasmedbio.2005.06.013
Hazle JD, Diederich CJ, Kangasniemi M, Price RE, Olsson LE, Stafford RJ. MRI-guided thermal therapy of transplanted tumors in the canine prostate using a directional transurethral ultrasound applicator. J Magn Reson Imaging. 2002;15:409-417.
Ren X-L, Zhou X-D, Zhang J, et al. Extracorporeal ablation of uterine fibroids with high-intensity focused ultrasound: imaging and histopathologic evaluation. J Ultrasound Med. 2007;26:201-212.
Vykhodtseva N, Sorrentino V, Jolesz FA, Bronson RT, Hynynen K. MRI detection of the thermal effects of focused ultrasound on the brain. Ultrasound Med Biol. 2000;26:871-880.
Zhou Y-F. High intensity focused ultrasound in clinical tumor ablation. World J Clin Oncol. 2011;2:8-27. doi:10.5306/wjco.v2.i1.8
Hijnen NM, Elevelt A, Grull H. Stability and trapping of magnetic resonance imaging contrast agents during high-intensity focused ultrasound ablation therapy. Invest Radiol. 2013;48:517-524. doi:10.1097/RLI.0b013e31829aae98
Hijnen NM, Elevelt A, Pikkemaat J, Bos C, Bartels LW, Grüll H. The magnetic susceptibility effect of gadolinium-based contrast agents on PRFS-based MR thermometry during thermal interventions. J Ther Ultrasound. 2013;1:8. doi:10.1186/2050-5736-1-8
Hectors SJCG, Jacobs I, Heijman E, et al. Multiparametric MRI analysis for the evaluation of MR-guided high intensity focused ultrasound tumor treatment. NMR Biomed. 2015;28:1125-1140. doi:10.1002/nbm.3350
Wijlemans JW, Deckers R, van den Bosch MAAJ, et al. Evolution of the ablation region after magnetic resonance-guided high-intensity focused ultrasound ablation in a Vx2 tumor model. Invest Radiol. 2013;48:381-386. doi:10.1097/RLI.0b013e3182820257
Miller D, Smith N, Bailey M, et al. Overview of therapeutic ultrasound applications and safety considerations. J Ultrasound Med. 2012;31:623-634.
Maleke C, Konofagou EE. In vivo feasibility of real-time monitoring of focused ultrasound surgery (FUS) using harmonic motion imaging (HMI). IEEE Trans Biomed Eng. 2010;57:7-11. doi:10.1109/TBME.2009.2027423
Sapin-De Brosses E, Gennisson JL, Pernot M, Fink M, Tanter M. Temperature dependence of the shear modulus of soft tissues assessed by ultrasound. Phys Med Biol. 2010;55:1701-1718. doi:10.1088/0031-9155/55/6/011
Arnal B, Pernot M, Tanter M. Monitoring of thermal therapy based on shear modulus changes. II: Shear wave imaging of thermal lesions. IEEE Trans Ultrason Ferroelectr Freq Control. 2011;58:1603-1611. doi:10.1109/TUFFC.2011.1987
Mariani A, Kwiecinski W, Pernot M, et al. Real time shear waves elastography monitoring of thermal ablation: in vivo evaluation in pig livers. J Surg Res. 2014;188:37-43. doi:10.1016/J.JSS.2013.12.024
Khan S, Fakhouri F, Majeed W, Kolipaka A. Cardiovascular magnetic resonance elastography: a review. NMR Biomed. 2018;31:e3853. doi:10.1002/nbm.3853
Manduca A, Oliphant TE, Dresner MA, et al. Magnetic resonance elastography: non-invasive mapping of tissue elasticity. Med Image Anal. 2001;5:237-254.
Chen J, Woodrum DA, Glaser KJ, Murphy MC, Gorny K, Ehman R. Assessment of in vivo laser ablation using MR elastography with an inertial driver. Magn Reson Med. 2014;72:59-67. doi:10.1002/MRM.24891
Corbin N, Vappou J, Breton E, et al. Interventional MR elastography for MRI-guided percutaneous procedures. Magn Reson Med. 2016;75:1110-1118. doi:10.1002/mrm.25694
Wu T, Felmlee JP, Greenleaf JF, Riederer SJ, Ehman RL. Assessment of thermal tissue ablation with MR elastography. Magn Reson Med. 2001;45:80-87. doi:10.1118/1.1570373
Vappou J, Bour P, Marquet F, Ozenne V, Quesson B. MR-ARFI-based method for the quantitative measurement of tissue elasticity: application for monitoring HIFU therapy. Phys Med Biol. 2018;63:095018. doi:10.1088/1361-6560/aabd0d
Bour P, Marquet F, Ozenne V, et al. Real-time monitoring of tissue displacement and temperature changes during MR-guided high intensity focused ultrasound. Magn Reson Med. 2017;78:1911-1921. doi:10.1002/MRM.26588
Wu T, Felmlee JP, Greenleaf JF, Riederer SJ, Ehman RL. MR imaging of shear waves generated by focused ultrasound. Magn Reson Med. 2000;43:111-115. doi:10.1002/(SICI)1522-2594(200001)43:1<111::AID-MRM13>3.0.CO;2-D
Le Y, Glaser K, Romano A, et al. Study of shear wave displacement change measured by 1D MRE during focused ultrasound treatment: preliminary study. AIP Conf Proc. 2006;829:186. doi:10.1063/1.2205463
Larrat B, Pernot M, Aubry JF, et al. MR-guided transcranial brain HIFU in small animal models. Phys Med Biol. 2010;55:365-388. doi:10.1088/0031-9155/55/2/003
Sinkus R, Robert B, Gennisson J, Tanter M, Fink M. Single breath hold transient MR-elastography of the heart-imaging pulsed shear wave propagation induced by aortic valve closure. In: Proceedings of the 14th Annual Meeting of ISMRM, Seattle, Washington, USA, 2006. p. 77.
Rouvière O, Gelet A, Crouzet S, Chapelon J-Y. Prostate focused ultrasound focal therapy-imaging for the future. Nat Rev Clin Oncol. 2012;9:721-727. doi:10.1038/nrclinonc.2012.136
Yuan L, Glaser KJ, Rouviere O, et al. Preliminary assessment of one-dimensional MR elastography for use in monitoring focused ultrasound therapy. Phys Med Biol. 2007;52:5909-5919. doi:10.1088/0031-9155/52/19/012
Bitton RR, Kaye E, Dirbas FM, Daniel BL, Pauly KB. Toward MR-guided high intensity focused ultrasound for presurgical localization: focused ultrasound lesions in cadaveric breast tissue. J Magn Reson Imaging. 2012;35:1089-1097. doi:10.1002/jmri.23529
Partanen A, Yerram NK, Trivedi H, et al. Magnetic resonance imaging (MRI)-guided transurethral ultrasound therapy of the prostate: a preclinical study with radiological and pathological correlation using customised MRI-based moulds. BJU Int. 2013;112:508-516. doi:10.1111/bju.12126
Jacobs MA, Ouwerkerk R, Kamel I, Bottomley PA, Bluemke DA, Kim HS. Proton, diffusion-weighted imaging, and sodium (23Na) MRI of uterine leiomyomata after MR-guided high-intensity focused ultrasound: a preliminary study. J Magn Reson Imaging. 2009;29:649-656. doi:10.1002/jmri.21677
Jacobs MA, Gultekin DH, Kim HS. Comparison between diffusion-weighted imaging, T1-weighted, and postcontrast T1-weighted imaging after MR-guided, high intensity, focused ultrasound treatment of uterine leiomyomata: preliminary results. Med Phys. 2010;37:4768-4776. doi:10.1118/1.3475940
Hectors SJCG, Jacobs I, Moonen CTW, Strijkers GJ, Nicolay K. MRI methods for the evaluation of high intensity focused ultrasound tumor treatment: current status and future needs. Magn Reson Med. 2016;75:302-317. doi:10.1002/mrm.25758
Zimmerman BE, Johnson S, Odeen H, et al. Learning multiparametric biomarkers for assessing MR-guided focused ultrasound treatment of malignant tumors. IEEE Trans Biomed Eng. 2021;68:1737-1747. doi:10.1109/TBME.2020.3024826
Plata JC, Holbrook AB, Marx M, et al. A feasibility study on monitoring the evolution of apparent diffusion coefficient decrease during thermal ablation. Med Phys. 2015;42:5130-5137. doi:10.1118/1.4928155
Peng HH, Huang TY, Tseng WYI, et al. Simultaneous temperature and magnetization transfer (MT) monitoring during high-intensity focused ultrasound (HIFU) treatment: preliminary investigation on ex vivo porcine muscle. J Magn Reson Imaging. 2009;30:596-605. doi:10.1002/jmri.21860
Odéen H, Todd N, Diakite M, Minalga E, Payne A, Parker DL. Sampling strategies for subsampled segmented EPI PRF thermometry in MR guided high intensity focused ultrasound. Med Phys. 2014;41:092301.
Odéen H, Parker DL. Improved MR thermometry for laser interstitial thermotherapy. Lasers Surg Med. 2019;300:286-300. doi:10.1002/lsm.23049
Payne A, Merrill R, Minalga E, et al. A breast-specific MR guided focused ultrasound platform and treatment protocol: first-in-human technical evaluation. IEEE Trans Biomed Eng. 2021;68:893-904.
Christensen KA, Grant DM, Schulman EM, Walling C. Optimal determination of relaxation times of fourier transform nuclear magnetic resonance. Determination of spin-lattice relaxation times in chemically polarized species. J Phys Chem. 1974;78:1971-1977. doi:10.1021/J100612A022
Wang HZ, Riederer SJ, Lee JN. Optimizing the precision in T1 relaxation estimation using limited flip angles. Magn Reson Med. 1987;5:399-416. doi:10.1002/MRM.1910050502
Schabel MC, Morrell GR. Uncertainty in T(1) mapping using the variable flip angle method with two flip angles. Phys Med Biol. 2009;54:N1-N8. doi:10.1088/0031-9155/54/1/N01
Svedin BT, Payne A, Parker DL. Simultaneous proton resonance frequency shift thermometry and T1 measurements using a single reference variable flip angle T1 method. Magn Reson Med. 2019;81:1-15. doi:10.1002/mrm.27643
Lena B, Bos C, Moonen CTW, Viergever MA, Bartels LW. Flip angle optimization and in vitro demonstration of 2D DESPOT1-based fat thermometry. In: Proceedings of the 27th Annual Meeting of ISMRM, Montréal, Quebec, Canada, 2019. p. 3829.
Hofstetter LW, Odéen H, Bolster BD, et al. Efficient shear wave elastography using transient acoustic radiation force excitations and MR displacement encoding. Magn Reson Med. 2019;81:3153-3167. doi:10.1002/mrm.27647
de Bever JT, Odéen H, Hofstetter LW, Parker DL. Simultaneous MR thermometry and acoustic radiation force imaging using interleaved acquisition. Magn Reson Med. 2018;79:1515-1524. doi:10.1002/mrm.26827
Odéen H, de Bever J, Hofstetter LW, Parker DL. Multiple-point magnetic resonance acoustic radiation force imaging. Magn Reson Med. 2019;81:1104-1117. doi:10.1002/mrm.27477
Farrer AI, Odéen H, de Bever J, et al. Characterization and evaluation of tissue-mimicking gelatin phantoms for use with MRgFUS. J Ther Ultrasound. 2015;3:9. doi:10.1186/s40349-015-0030-y
Chung S, Kim D, Breton E, Axel L. Rapid B1+ mapping using a preconditioning RF pulse with TurboFLASH readout. Magn Reson Med. 2010;64:439-446. doi:10.1002/mrm.22423
Svedin BT, Payne A, Bolster BD, Parker DL. Multiecho pseudo-golden angle stack of stars thermometry with high spatial and temporal resolution using k-space weighted image contrast. Magn Reson Med. 2018;79:1407-1419. doi:10.1002/mrm.26797
Roemer PB, Edelstein WA, Hayes CE, Souza SP, Mueller OM. The NMR phased array. Magn Reson Med. 1990;16:192-225. doi:10.1002/mrm.1910160203
Parker DL, Payne A, Todd N, Hadley JR. Phase reconstruction from multiple coil data using a virtual reference coil. Magn Reson Med. 2014;72:563-569. doi:10.1002/mrm.24932
Parker DL, Payne A, Odéen H. A k-space-based method to measure and correct for temporal B0 field variations in MR temperature imaging. Magn Reson Med. 2022;88:1-14. doi:10.1002/mrm.29275
Henrik Odéen, Sara Johnson, Allison Payne, Dennis L Parker. Towards correlating tissue status with dynamic PRF-T1 measurements using a single reference dual flip angle technique. In Proceedings of the 30th Annual Meeting of ISMRM [Virtual], 2021. p. 1267.
Todd N, Adluru G, Payne A, DiBella EVR, Parker D. Temporally constrained reconstruction applied to MRI temperature data. Magn Reson Med. 2009;62:406-419. doi:10.1002/mrm.22012
Hofstetter LW, Odeen H, Bolster BD, Christensen DA, Payne A, Parker DL. Magnetic resonance shear wave elastography using transient acoustic radiation force excitations and sinusoidal displacement encoding. Phys Med Biol. 2021;66. doi:10.1088/1361-6560/abd5ce
Adluru G, Awate SP, Tasdizen T, Whitaker RT, Dibella EVR. Temporally constrained reconstruction of dynamic cardiac perfusion MRI. Magn Reson Med. 2007;57:1027-1036. doi:10.1002/mrm.21248
Parker DL, Du YP, Davis WL. The voxel sensitivity function in Fourier transform imaging: applications to magnetic resonance angiography. Magn Reson Med. 1995;33:156-162. doi: 10.1002/mrm.1910330203
Todd N, Vyas U, de Bever J, Payne A, Parker DL. The effects of spatial sampling choices on MR temperature measurements. Magn Reson Med. 2011;65:515-521. doi:10.1002/mrm.22636

Auteurs

Henrik Odéen (H)

Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, USA.

Lorne W Hofstetter (LW)

Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, USA.

Allison H Payne (AH)

Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, USA.

Ludovic Guiraud (L)

Image Guided Therapy, Pessac, France.

Erik Dumont (E)

Image Guided Therapy, Pessac, France.

Dennis L Parker (DL)

Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, USA.

Articles similaires

Humans Ketamine Propofol Pulmonary Atelectasis Female
Robotic Surgical Procedures Animals Humans Telemedicine Models, Animal

Odour generalisation and detection dog training.

Lyn Caldicott, Thomas W Pike, Helen E Zulch et al.
1.00
Animals Odorants Dogs Generalization, Psychological Smell
Animals TOR Serine-Threonine Kinases Colorectal Neoplasms Colitis Mice

Classifications MeSH