Photon-counting computed tomography (PCCT) imaging uses a new detector technology to provide added information beyond what can already be obtained with current CT and MR technologies. This review provides an overview of PCCT of the abdomen and focuses specifically on applications that benefit the most from this new imaging technique. We describe the requirements for a successful abdominal PCCT acquisition and the challenges for clinical translation. The review highlights work done within the last year with an emphasis on new protocols that have been tested in clinical practice. Applications of PCCT include imaging of cystic lesions, sources of bleeding, and cancers. Photon-counting CT is positioned to move beyond detection of disease to better quantitative staging of disease and measurement of treatment response.
Identifiants
pubmed: 36728045
doi: 10.1097/RLI.0000000000000949
pii: 00004424-202307000-00007
doi:
Types de publication
Review
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
488-498Informations de copyright
Copyright © 2023 Wolters Kluwer Health, Inc. All rights reserved.
Déclaration de conflit d'intérêts
Conflicts of interest and sources of funding: none declared.
Références
Hounsfield GN. Computerized transverse axial scanning (tomography). 1. Description of system. Br J Radiol . 1973;46:1016–1022.
Martin C. The importance of radiation quality for optimisation in radiology. Biomed Imaging Interv J . 2007;3:e38.
Sawall S, Klein L, Amato C, et al. Iodine contrast-to-noise ratio improvement at unit dose and contrast media volume reduction in whole-body photon-counting CT. Eur J Radiol . 2020;126:108909.
Patino M, Prochowski A, Agrawal MD, et al. Material separation using dual-energy CT: current and emerging applications. Radiographics . 2016;36:1087–1105.
Willemink MJ, Persson M, Pourmorteza A, et al. Photon-counting CT: technical principles and clinical prospects. Radiology . 2018;289:293–312.
Chiro GD, Brooks RA, Kessler RM, et al. Tissue signatures with dual-energy computed tomography. Radiology . 1979;131:521–523.
Alvarez RE, Macovski A. Energy-selective reconstructions in x-ray computerized tomography. Phys Med Biol . 1976;21:733–744.
Taguchi K, Iwanczyk JS. Vision 20/20: single photon counting x-ray detectors in medical imaging. Med Phys . 2013;40:100901.
Danielsson M, Persson M, Sjölin M. Photon-counting x-ray detectors for CT. Phys Med Biol . 2021;66:03tr1.
Leng S, Bruesewitz M, Tao S, et al. Photon-counting detector CT: system design and clinical applications of an emerging technology. Radiographics . 2019;39:729–743.
Yu Z, Leng S, Jorgensen SM, et al. Evaluation of conventional imaging performance in a research whole-body CT system with a photon-counting detector array. Phys Med Biol . 2016;61:1572–1595.
Yu Z, Leng S, Li Z, et al. How low can we go in radiation dose for the data-completion scan on a research whole-body photon-counting computed tomography system. J Comput Assist Tomogr . 2016;40:663–670.
Decker JA, Bette S, Lubina N, et al. Low-dose CT of the abdomen: initial experience on a novel photon-counting detector CT and comparison with energy-integrating detector CT. Eur J Radiol . 2022;148:110181.
Pourmorteza A, Symons R, Henning A, et al. Dose efficiency of quarter-millimeter photon-counting computed tomography: first-in-human results. Invest Radiol . 2018;53:365–372.
Do TD, Sawall S, Heinze S, et al. A semi-automated quantitative comparison of metal artifact reduction in photon-counting computed tomography by energy-selective thresholding. Sci Rep . 2020;10:21099.
Zhou W, Michalak GJ, Weaver JM, et al. A universal protocol for abdominal CT examinations performed on a photon-counting detector CT system: a feasibility study. Invest Radiol . 2020;55:226–232.
Gutjahr R, Halaweish AF, Yu Z, et al. Human imaging with photon counting-based computed tomography at clinical dose levels: contrast-to-noise ratio and cadaver studies. Invest Radiol . 2016;51:421–429.
Schmidt TG. CT energy weighting in the presence of scatter and limited energy resolution. Med Phys . 2010;37:1056–1067.
Sartoretti T, Landsmann A, Nakhostin D, et al. Quantum iterative reconstruction for abdominal photon-counting detector CT improves image quality. Radiology . 2022;303:339–348.
Eberhard M, Mergen V, Higashigaito K, et al. Coronary calcium scoring with first generation dual-source photon-counting CT—first evidence from phantom and in-vivo scans. Diagnostics . 2021;11:1708.
Ferrero A, Gutjahr R, Halaweish AF, et al. Characterization of urinary stone composition by use of whole-body, photon-counting detector CT. Acad Radiol . 2018;25:1270–1276.
Mileto A, Ananthakrishnan L, Morgan DE, et al. Clinical implementation of dual-energy CT for gastrointestinal imaging. AJR Am J Roentgenol . 2021;17:651–663.
McCollough CH, Leng S, Yu L, et al. Dual- and multi-energy CT: principles, technical approaches, and clinical applications. Radiology . 2015;276:637–653.
Yu L, Leng S, McCollough CH. Dual-energy CT-based monochromatic imaging. AJR Am J Roentgenol . 2012;199(suppl 5):S9–S15.
Higashigaito K, Euler A, Eberhard M, et al. Contrast-enhanced abdominal CT with clinical photon-counting detector CT: assessment of image quality and comparison with energy-integrating detector CT. Acad Radiol . 2022;29:689–697.
Holscher CM, Ishaque T, Garonzik Wang JM, et al. Living donor postnephrectomy kidney function and recipient graft loss: a dose-response relationship. Am J Transplant . 2018;18:2804–2810.
Sawall S, Klein L, Wehrse E, et al. Threshold-dependent iodine imaging and spectral separation in a whole-body photon-counting CT system. Eur Radiol . 2021;31:6631–6639.
Jacobsen MC, Schellingerhout D, Wood CA, et al. Intermanufacturer comparison of dual-energy CT iodine quantification and monochromatic attenuation: a phantom study. Radiology . 2018;287:224–234.
Mileto A, Barina A, Marin D, et al. Virtual monochromatic images from dual-energy multidetector CT: variance in CT numbers from the same lesion between single-source projection-based and dual-source image-based implementations. Radiology . 2016;279:269–277.
Toia GV, Mileto A, Wang CL, et al. Quantitative dual-energy CT techniques in the abdomen. Abdom Radiol (NY) . 2022;47:3003–3018.
Bhayana R, Parakh A, Kambadakone A. Material decomposition with dual- and multi-energy computed tomography. MRS Communications . 2020;10:558–565.
Lennartz S, Schoenbeck D, Kröger JR, et al. Photon-counting CT material decomposition: initial experience in assessing adrenal adenoma. Radiology . 2022;220919.
Ruth V, Kolditz D, Steiding C, et al. Investigation of spectral performance for single-scan contrast-enhanced breast CT using photon-counting technology: a phantom study. Med Phys . 2020;47:2826–2837.
Liu LP, Shapira N, Chen AA, et al. First-generation clinical dual-source photon-counting CT: ultra-low-dose quantitative spectral imaging. Eur Radiol . 2022;32:8579–8587.
Sartoretti T, Mergen V, Higashigaito K, et al. Virtual noncontrast imaging of the liver using photon-counting detector computed tomography: a systematic phantom and patient study. Invest Radiol . 2022;57:488–493.
Sartoretti T, Mergen V, Jungblut L, et al. Liver iodine quantification with photon-counting detector CT: accuracy in an abdominal phantom and feasibility in patients. Acad Radiol . 2022;S1076-6332:00268–00269.
Mergen V, Racine D, Jungblut L, et al. Virtual noncontrast abdominal imaging with photon-counting detector CT. Radiology . 2022;305:107–115.
Burkhart RA, Pawlik TM. Staging and prognostic models for hepatocellular carcinoma and intrahepatic cholangiocarcinoma. Cancer Control . 2017;24:1073274817729235.
Chernyak V, Fowler KJ, Kamaya A, et al. Liver imaging reporting and data system (LI-RADS) version 2018: imaging of hepatocellular carcinoma in at-risk patients. Radiology . 2018;289:816–830.
Ren L, Huber N, Rajendran K, et al. Dual-contrast biphasic liver imaging with iodine and gadolinium using photon-counting detector computed tomography: an exploratory animal study. Invest Radiol . 2022;57:122–129.
Cuccione E, Chhour P, Si-Mohamed S, et al. Multicolor spectral photon counting CT monitors and quantifies therapeutic cells and their encapsulating scaffold in a model of brain damage. Nanotheranostics . 2020;4:129–141.
Si-Mohamed S, Cormode DP, Bar-Ness D, et al. Evaluation of spectral photon counting computed tomography K-edge imaging for determination of gold nanoparticle biodistribution in vivo. Nanoscale . 2017;9:18246–18257.
Saleh M, Virarkar M, Bura V, et al. Intrahepatic cholangiocarcinoma: pathogenesis, current staging, and radiological findings. Abdom Radiol (NY) . 2020;45:3662–3680.
Slattery JM, Sahani DV. What is the current state-of-the-art imaging for detection and staging of cholangiocarcinoma? Oncologist . 2006;11:913–922.
Euler A, Higashigaito K, Mergen V, et al. High-pitch photon-counting detector computed tomography angiography of the aorta: intraindividual comparison to energy-integrating detector computed tomography at equal radiation dose. Invest Radiol . 2022;57:115–121.
Jungblut L, Kronenberg D, Mergen V, et al. Impact of contrast enhancement and virtual monoenergetic image energy levels on emphysema quantification: experience with photon-counting detector computed tomography. Invest Radiol . 2022;57:359–365.
Graafen D, Müller L, Halfmann M, et al. Photon-counting detector CT improves quality of arterial phase abdominal scans: a head-to-head comparison with energy-integrating CT. Eur J Radiol . 2022;156:110514.
Hagen F, Hofmann J, Wrazidlo R, et al. Image quality and dose exposure of contrast-enhanced abdominal CT on a 1st generation clinical dual-source photon-counting detector CT in obese patients vs. a 2nd generation dual-source dual energy integrating detector CT. Eur J Radiol . 2022;151:110325.
Sahani DV, Kalva SP, Fischman AJ, et al. Detection of liver metastases from adenocarcinoma of the colon and pancreas: comparison of mangafodipir trisodium-enhanced liver MRI and whole-body FDG PET. AJR Am J Roentgenol . 2005;185:239–246.
Sivesgaard K, Larsen LP, Sørensen M, et al. Diagnostic accuracy of CE-CT, MRI and FDG PET/CT for detecting colorectal cancer liver metastases in patients considered eligible for hepatic resection and/or local ablation. Eur Radiol . 2018;28:4735–4747.
Nakai H, Arizono S, Isoda H, et al. Imaging characteristics of liver metastases overlooked at contrast-enhanced CT. AJR Am J Roentgenol . 2019;212:782–787.
Racine D, Mergen V, Viry A, et al. Photon-counting detector CT with quantum iterative reconstruction: impact on liver lesion detection and radiation dose reduction. Invest Radiol . 2022.
Bette S, Decker JA, Braun FM, et al. Optimal conspicuity of liver metastases in virtual monochromatic imaging reconstructions on a novel photon-counting detector CT-effect of keV settings and BMI. Diagnostics (Basel) . 2022;12:1231.
Chalasani N, Younossi Z, Lavine JE, et al. The diagnosis and management of nonalcoholic fatty liver disease: practice guidance from the American Association for the Study of Liver Diseases. Hepatology . 2018;67:328–357.
Reeder SB, Hu HH, Sirlin CB. Proton density fat-fraction: a standardized MR-based biomarker of tissue fat concentration. J Magn Reson Imaging . 2012;36:1011–1014.
Doda Khera R, Homayounieh F, Lades F, et al. Can dual-energy computed tomography quantitative analysis and radiomics differentiate normal liver from hepatic steatosis and cirrhosis? J Comput Assist Tomogr . 2020;44:223–229.
Niehoff JH, Woeltjen MM, Saeed S, et al. Assessment of hepatic steatosis based on virtual non-contrast computed tomography: initial experiences with a photon counting scanner approved for clinical use. Eur J Radiol . 2022;149:110185.
Rajendran K, Petersilka M, Henning A, et al. First clinical photon-counting detector CT system: technical evaluation. Radiology . 303:130–138.
Grossberg AJ, Chu LC, Deig CR, et al. Multidisciplinary standards of care and recent progress in pancreatic ductal adenocarcinoma. CA Cancer J Clin . 2020;70:375–403.
Gandhi NS, Feldman MK, Le O, et al. Imaging mimics of pancreatic ductal adenocarcinoma. Abdom Radiol (NY) . 2018;43:273–284.
Perri G, Prakash LR, Katz MHG. Pancreatic neuroendocrine tumors. Curr Opin Gastroenterol . 2019;35:468–477.
Lee L, Ito T, Jensen RT. Imaging of pancreatic neuroendocrine tumors: recent advances, current status, and controversies. Expert Rev Anticancer Ther . 2018;18:837–860.
Bollen TL, Wessels FJ. Radiological workup of cystic neoplasms of the pancreas. Visc Med . 2018;34:182–190.
Yoon JG, Smith D, Ojili V, et al. Pancreatic cystic neoplasms: a review of current recommendations for surveillance and management. Abdom Radiol (NY) . 2021;46:3946–3962.
Scheiman JM, Hwang JH, Moayyedi P. American gastroenterological association technical review on the diagnosis and management of asymptomatic neoplastic pancreatic cysts. Gastroenterology . 2015;148:824–48.e22.
Guglielmo FF, Wells ML, Bruining DH, et al. Gastrointestinal bleeding at CT angiography and CT enterography: imaging atlas and glossary of terms. Radiographics . 2021;41:1632–1656.
Aoki T, Hirata Y, Yamada A, et al. Initial management for acute lower gastrointestinal bleeding. World J Gastroenterol . 2019;25:69–84.
Podolsky DK. The current future understanding of inflammatory bowel disease. Best Pract Res Clin Gastroenterol . 2002;16:933–943.
Shanbhogue AKP, Prasad SR, Jagirdar J, et al. Comprehensive update on select immune-mediated gastroenterocolitis syndromes: implications for diagnosis and management. Radiographics . 2010;30:1465–1487.
Flynn S, Eisenstein S. Inflammatory bowel disease presentation and diagnosis. Surg Clin North Am . 2019;99:1051–1062.
Guglielmo FF, Anupindi SA, Fletcher JG, et al. Small bowel Crohn disease at CT and MR enterography: imaging atlas and glossary of terms. Radiographics . 2020;40:354–375.
Gajendran M, Loganathan P, Jimenez G, et al. A comprehensive review and update on ulcerative colitis. Dis Mon . 2019;65:100851.
Bruining D, Zimmermann E, Loftus E Jr., et al. Consensus recommendations for evaluation, interpretation, and utilization of computed tomography and magnetic resonance enterography in patients with small bowel Crohn's disease. Radiology . 2018;286:776–799.
Fulwadhva UP, Wortman JR, Sodickson AD. Use of dual-energy CT and iodine maps in evaluation of bowel disease. Radiographics . 2016;36:393–406.
Schwartz FR, Vinson EN, Spritzer CE, et al. Prospective multireader evaluation of photon-counting CT for multiple myeloma screening. Radiol Imaging Cancer . 2022;4:e220073.
Wang ZJ, Nikolaidis P, Khatri G, et al; Expert Panel on Urologic Imaging. ACR appropriateness criteria® indeterminate renal mass. J Am Coll Radiol . 2020;17:S415–S428.
Ward RD, Tanaka H, Campbell SC, et al. 2017 AUA renal mass and localized renal cancer guidelines: imaging implications. Radiographics . 2018;38:2021–2033.
Abou Elkassem AM, Lo SS, Gunn AJ, et al. Role of imaging in renal cell carcinoma: a multidisciplinary perspective. Radiographics . 2021;41:1387–1407.
Silverman SG, Pedrosa I, Ellis JH, et al. Bosniak classification of cystic renal masses, version 2019: an update proposal and needs assessment. Radiology . 2019;292:475–488.
Smith AD, Carson JD, Sirous R, et al. Active surveillance versus nephron-sparing surgery for a Bosniak IIF or III renal cyst: a cost-effectiveness analysis. Am J Roentgenol . 2019;212:830–838.
Wang Z, Davenport M, Silverman S. CT renal mass protocols v1.0. Society of Abdominal Radiology . 2017;2019.
Sasaguri K, Takahashi N. CT and MR imaging for solid renal mass characterization. Eur J Radiol . 2018;99:40–54.
Ali O, Fishman EK, Sheth S. Upper urinary tract urothelial carcinoma on multidetector CT: spectrum of disease. Abdom Radiol (NY) . 2019;44:3874–3885.
Caoili EM, Cohan RH. CT urography in evaluation of urothelial tumors of the kidney. Abdom Radiol . 2016;41:1100–1107.
Kaza RK, Ananthakrishnan L, Kambadakone A, et al. Update of dual-energy CT applications in the genitourinary tract. Am J Roentgenol . 2017;208:1185–1192.
Stein EB, Roseland ME, Shampain KL, et al. Contemporary guidelines for adnexal mass imaging: a 2020 update. Abdom Radiol (NY) . 2021;46:2127–2139.
Flicek KT, VanBuren W, Dudiak K, et al. Borderline epithelial ovarian tumors: what the radiologist should know. Abdom Radiol (NY) . 2021;46:2350–2366.
Litwin MS, Tan HJ. The diagnosis and treatment of prostate cancer: a review. JAMA . 2017;317:2532–2542.