Pharmacokinetics and tolerability of prefilled syringe and auto-injector presentations of MSB11456: results of a randomized, single-dose study in healthy adults.


Journal

Expert review of clinical immunology
ISSN: 1744-8409
Titre abrégé: Expert Rev Clin Immunol
Pays: England
ID NLM: 101271248

Informations de publication

Date de publication:
04 2023
Historique:
medline: 20 4 2023
pubmed: 16 2 2023
entrez: 15 2 2023
Statut: ppublish

Résumé

Tocilizumab is a monoclonal immunoglobulin G interleukin-6 receptor antagonist. MSB11456 is a proposed tocilizumab biosimilar. To determine the pharmacokinetic equivalence of a single subcutaneous injection of MSB11456, when delivered via autoinjector (AI) and prefilled syringe (PFS), in healthy adult subjects. In this randomized, open-label, single fixed-dose, crossover study, 91 subjects received subcutaneous administration of tocilizumab 162 mg via AI and PFS presentations. The primary endpoint pharmacokinetic parameters were analyzed using analysis of variance. Safety data were summarized descriptively. There were no differences in pharmacokinetic parameters between presentations, and safety parameters were comparable. The 90% confidence intervals for the geometric least squares mean ratios of all primary pharmacokinetic parameters were contained within the predefined 80.00% to 125.00% bioequivalence limits, indicating pharmacokinetic equivalence between the AI and PFS. MSB11456 administration via AI was bioequivalent to administration via PFS. MSB11456 can be administered by AI or PFS, increasing the available range of self-injection devices. The trial is registered at EudraCT, number 2020-003419-86. Tocilizumab is a biologic drug that is used to treat autoimmune diseases, including rheumatoid arthritis. MSB11456 has been shown to be equivalent to the US-licensed and EU-approved tocilizumab when administered by subcutaneous injection. There are different devices available to administer subcutaneous injections, and depending on the device, the patient’s experience can be enhanced, convenience and compliance increased, and cost-effectiveness ensured for patients taking this medicine. This randomized, single fixed-dose, crossover study tested the pharmacokinetic similarity of MSB11456 when given subcutaneously via an auto-injector device versus a pre-filled syringe device in 100 healthy subjects. A total of 91 healthy volunteers received MSB11456 via both auto-injector and pre-filled syringe using a crossover design. Blood was collected before the first dose and at regular intervals during the study to determine the pharmacokinetics of tocilizumab and ensure safety. This study found that the pharmacokinetics of tocilizumab following administration using the autoinjector and the prefilled syringe were equivalent, and the safety profiles were similar. These findings indicate that the auto-injector can be considered another option that can be used to subcutaneously inject MSB11456.

Sections du résumé

BACKGROUND
Tocilizumab is a monoclonal immunoglobulin G interleukin-6 receptor antagonist. MSB11456 is a proposed tocilizumab biosimilar.
OBJECTIVE
To determine the pharmacokinetic equivalence of a single subcutaneous injection of MSB11456, when delivered via autoinjector (AI) and prefilled syringe (PFS), in healthy adult subjects.
RESEARCH DESIGN AND METHODS
In this randomized, open-label, single fixed-dose, crossover study, 91 subjects received subcutaneous administration of tocilizumab 162 mg via AI and PFS presentations. The primary endpoint pharmacokinetic parameters were analyzed using analysis of variance. Safety data were summarized descriptively.
RESULTS
There were no differences in pharmacokinetic parameters between presentations, and safety parameters were comparable. The 90% confidence intervals for the geometric least squares mean ratios of all primary pharmacokinetic parameters were contained within the predefined 80.00% to 125.00% bioequivalence limits, indicating pharmacokinetic equivalence between the AI and PFS.
CONCLUSIONS
MSB11456 administration via AI was bioequivalent to administration via PFS. MSB11456 can be administered by AI or PFS, increasing the available range of self-injection devices.
TRIAL REGISTRATION
The trial is registered at EudraCT, number 2020-003419-86.
Tocilizumab is a biologic drug that is used to treat autoimmune diseases, including rheumatoid arthritis. MSB11456 has been shown to be equivalent to the US-licensed and EU-approved tocilizumab when administered by subcutaneous injection. There are different devices available to administer subcutaneous injections, and depending on the device, the patient’s experience can be enhanced, convenience and compliance increased, and cost-effectiveness ensured for patients taking this medicine. This randomized, single fixed-dose, crossover study tested the pharmacokinetic similarity of MSB11456 when given subcutaneously via an auto-injector device versus a pre-filled syringe device in 100 healthy subjects. A total of 91 healthy volunteers received MSB11456 via both auto-injector and pre-filled syringe using a crossover design. Blood was collected before the first dose and at regular intervals during the study to determine the pharmacokinetics of tocilizumab and ensure safety. This study found that the pharmacokinetics of tocilizumab following administration using the autoinjector and the prefilled syringe were equivalent, and the safety profiles were similar. These findings indicate that the auto-injector can be considered another option that can be used to subcutaneously inject MSB11456.

Autres résumés

Type: plain-language-summary (eng)
Tocilizumab is a biologic drug that is used to treat autoimmune diseases, including rheumatoid arthritis. MSB11456 has been shown to be equivalent to the US-licensed and EU-approved tocilizumab when administered by subcutaneous injection. There are different devices available to administer subcutaneous injections, and depending on the device, the patient’s experience can be enhanced, convenience and compliance increased, and cost-effectiveness ensured for patients taking this medicine. This randomized, single fixed-dose, crossover study tested the pharmacokinetic similarity of MSB11456 when given subcutaneously via an auto-injector device versus a pre-filled syringe device in 100 healthy subjects. A total of 91 healthy volunteers received MSB11456 via both auto-injector and pre-filled syringe using a crossover design. Blood was collected before the first dose and at regular intervals during the study to determine the pharmacokinetics of tocilizumab and ensure safety. This study found that the pharmacokinetics of tocilizumab following administration using the autoinjector and the prefilled syringe were equivalent, and the safety profiles were similar. These findings indicate that the auto-injector can be considered another option that can be used to subcutaneously inject MSB11456.

Identifiants

pubmed: 36789991
doi: 10.1080/1744666X.2023.2174970
doi:

Substances chimiques

tocilizumab I031V2H011
Antibodies, Monoclonal, Humanized 0

Banques de données

EudraCT
['2020–003419-86']

Types de publication

Randomized Controlled Trial Journal Article Research Support, Non-U.S. Gov't

Langues

eng

Sous-ensembles de citation

IM

Pagination

447-455

Auteurs

Monika Tomaszewska-Kiecana (M)

Biokinetica S.A. Phase 1 Unit, Jozefow, Poland.

Anna Dryja (A)

MTZ Clinical Research Sp Z O O, Warsaw, Poland.

Martin Ullmann (M)

Biosimilars, Fresenius Kabi SwissBioSim, Switzerland.

Corinne Petit-Frere (C)

Biosimilars, Fresenius Kabi SwissBioSim, Switzerland.

Andras Illes (A)

Biosimilars, Fresenius Kabi SwissBioSim, Switzerland.

Christos Dagres (C)

Biosimilars, Fresenius Kabi SwissBioSim, Switzerland.

Joëlle Monnet (J)

Biosimilars, Fresenius Kabi SwissBioSim, Switzerland.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH