Evaluation of marginal and internal fit of single crowns manufactured with an analog workflow and three CAD-CAM systems: A prospective clinical study.


Journal

Journal of prosthodontics : official journal of the American College of Prosthodontists
ISSN: 1532-849X
Titre abrégé: J Prosthodont
Pays: United States
ID NLM: 9301275

Informations de publication

Date de publication:
Oct 2023
Historique:
received: 03 09 2022
accepted: 02 03 2023
medline: 23 10 2023
pubmed: 9 3 2023
entrez: 8 3 2023
Statut: ppublish

Résumé

This prospective clinical study evaluated and compared the marginal and internal fit of crowns fabricated with an analog workflow and three different computer-aided design and computer-aided manufacturing (CAD-CAM) systems. Twenty-five participants in need of a single complete-coverage molar or premolar crown were recruited in the study. Twenty-two completed the study, and three participants dropped out. Teeth were prepared according to a standardized protocol by one operator. For each participant, one final impression was made with polyether material (PP) and three intraoral scanners: CEREC Omnicam (C), Planmeca Planscan (PM), and True Definition (TR). For the PP group, crowns were fabricated with a pressable lithium disilicate ceramic, whereas for the other three groups (C, PM, and TR), crowns were designed and milled with dedicated CAD-CAM systems and materials. Marginal (vertical and horizontal) and internal discrepancies between the crowns and tooth preparation were measured at various locations with digital superimposition software. Data was analyzed for normality with Kolmogorov-Smirnov and Shapiro-Wilk tests and then compared with one-way ANOVA and Kruskal-Wallis tests. Mean vertical marginal gap values were 92.18 ± 141.41 μm (PP), 150.12 ± 138.06 μm (C), 129.07 ± 109.96 μm (PM), and 135.09 ± 112.03 μm (TR). PP group had statistically significantly smaller vertical marginal discrepancy (p = 0.001) than all other groups, whereas no significant difference was detected among the three CAD-CAM systems (C, PM, and TR). Horizontal marginal discrepancies were 104.93 ± 111.96 μm (PP), 89.49 ± 119.66 μm (C), 113.36 ± 128.49 μm (PM), and 136.39 ± 142.52 μm (TR). A significant difference was detected only between C and TR (p < 0.0001). Values for the internal fit were 128.40 ± 49.31μm (PP), 190.70 ± 69.79μm (C), 146.30 ± 57.70 μm (PM), and 168.20 ± 86.67 μm (TR). The PP group had a statistically significant smaller internal discrepancy than C (p < 0.0001) and TR groups (p = 0.001), whereas no significant difference was found compared to the PM group. Posterior crowns fabricated with CAD-CAM systems showed vertical margin discrepancy greater than 120 μm. Only crowns fabricated with the conventional methodology had vertical margins below 100 μm. Horizontal marginal discrepancy was different among all groups, and only CEREC CAD-CAM was below 100 μm. Internal discrepancy was less for crowns fabricated with an analog workflow.

Identifiants

pubmed: 36883776
doi: 10.1111/jopr.13675
doi:

Substances chimiques

Dental Porcelain 12001-21-7

Types de publication

Journal Article

Langues

eng

Pagination

689-696

Informations de copyright

© 2023 by the American College of Prosthodontists.

Références

McLean JW, von Fraunhofer JA. The estimation of cement film thickness by an in vivo technique. Br Dent J. 1971;131:107-11.
Christensen GJ. Marginal fit of gold inlay castings. J Prosthet Dent. 1966;16:297-305.
Mitchell CA, Pintado MR, Douglas WH. Nondestructive, in vitro quantification of crown margins. J Prosthet Dent. 2001;85:575-84.
Syrek A, Reich G, Ranftl D, Klein C, Cerny B, Brodesser J. Clinical evaluation of all-ceramic crowns fabricated from intraoral digital impressions based on the principle of active wavefront sampling. J Dent. 2010;38:553-9.
Goujat A, Abouelleil H, Colon P, Jeannin C, Pradelle N, Seux D, et al. Marginal and internal fit of CAD-CAM inlay/onlay restorations: a systematic review of in vitro studies. J Prosthet Dent. 2019;121:590-7.e3.
Tsirogiannis P, Reissmann DR, Heydecke G. Evaluation of the marginal fit of single-unit, complete-coverage ceramic restorations fabricated after digital and conventional impressions: a systematic review and meta-analysis. J Prosthet Dent. 2016;116:328-35.e2.
Chochlidakis KM, Papaspyridakos P, Geminiani A, Chen CJ, Feng IJ, Ercoli C. Digital versus conventional impressions for fixed prosthodontics: a systematic review and meta-analysis. J Prosthet Dent. 2016;116:184-90.e12.
Ng J, Ruse D, Wyatt C. A comparison of the marginal fit of crowns fabricated with digital and conventional methods. J Prosthet Dent. 2014;112:555-60.
Seelbach P, Brueckel C, Wöstmann B. Accuracy of digital and conventional impression techniques and workflow. Clin Oral Investig. 2013;17:1759-64.
De Freitas BN, Tonin BSH, Macedo AP, Dos Santos TMP, De Mattos M, Hotta TH, et al. Adaptation accuracy of milled lithium disilicate crowns: a 2D and 3D microCT analysis. J Esthet Restor Dent. 2020;32:403-9.
Anadioti E, Aquilino SA, Gratton DG, Holloway JA, Denry I, Thomas GW, et al. 3D and 2D marginal fit of pressed and CAD/CAM lithium disilicate crowns made from digital and conventional impressions. J Prosthodont. 2014;23:610-7.
Papadiochou S, Pissiotis AL. Marginal adaptation and CAD-CAM technology: a systematic review of restorative material and fabrication techniques. J Prosthet Dent. 2018;119:545-51.
Boitelle P, Tapie L, Mawussi B, Fromentin O. Evaluation of the marginal fit of CAD-CAM zirconia copings: comparison of 2D and 3D measurement methods. J Prosthet Dent. 2018;119:75-81.
Lee B, Oh KC, Haam D, Lee JH, Moon HS. Evaluation of the fit of zirconia copings fabricated by direct and indirect digital scanning procedures. J Prosthet Dent. 2018;120:225-31.
Bosch G, Ender A, Mehl A. A 3-dimensional accuracy analysis of chairside CAD/CAM milling processes. J Prosthet Dent. 2014;112:1425-31.
Christensen GJ. Impressions are changing: deciding on conventional, digital or digital plus in-office milling. J Am Dent Assoc. 2009;140:1301-4.
Memari Y, Mohajerfar M, Armin A, Kamalian F, Rezayani V, Beyabanaki E. Marginal adaptation of CAD/CAM all-ceramic crowns made by different impression methods: a literature review. J Prosthodont. 2019;28:e536-44.
Moher D, Liberati A, Tetzlaff J, Altman DG. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. PLoS Med. 2009;6:e1000097.
Huang X, Lin J, Demner-Fushman D. Evaluation of PICO as a knowledge representation for clinical questions. AMIA Annu Symp Proc. 2006;2006:359-63.
Almeida e Silva JS, Erdelt K, Edelhoff D, Araújo É, Stimmelmayr M, Vieira LC, et al. Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques. Clin Oral Investig. 2014;18:515-23.
An S, Kim S, Choi H, Lee JH, Moon HS. Evaluating the marginal fit of zirconia copings with digital impressions with an intraoral digital scanner. J Prosthet Dent. 2014;112:1171-5.
Anadioti E, Aquilino SA, Gratton DG, Holloway JA, Denry IL, Thomas GW, et al. Internal fit of pressed and computer-aided design/computer-aided manufacturing ceramic crowns made from digital and conventional impressions. J Prosthet Dent. 2015;113:304-9.
Keul C, Stawarczyk B, Erdelt KJ, Beuer F, Edelhoff D, Güth JF. Fit of 4-unit FDPs made of zirconia and CoCr-alloy after chairside and labside digitalization-a laboratory study. Dent Mater. 2014;30:400-7.
Pradíes G, Zarauz C, Valverde A, Ferreiroa A, Martínez-Rus F: clinical evaluation comparing the fit of all-ceramic crowns obtained from silicone and digital intraoral impressions based on wavefront sampling technology. J Dent. 2015;43:201-8.
Svanborg P, Skjerven H, Carlsson P, Eliasson A, Karlsson S, Ortorp A. Marginal and internal fit of cobalt-chromium fixed dental prostheses generated from digital and conventional impressions. Int J Dent. 2014;2014:534382.
Tidehag P, Ottosson K, Sjögren G. Accuracy of ceramic restorations made using an in-office optical scanning technique: an in vitro study. Oper Dent. 2014;39:308-16.
Mously HA, Finkelman M, Zandparsa R, Hirayama H. Marginal and internal adaptation of ceramic crown restorations fabricated with CAD/CAM technology and the heat-press technique. J Prosthet Dent. 2014;112:249-56.
Luthardt RG, Bornemann G, Lemelson S, Walter MH, Hüls A. An innovative method for evaluation of the 3-D internal fit of CAD/CAM crowns fabricated after direct optical versus indirect laser scan digitizing. Int J Prosthodont. 2004;17:680-5.
Segerström S, Wiking-Lima de Faria J, Braian M, Ameri A, Ahlgren C. A validation study of the impression replica technique. J Prosthodont. 2019;28:e609-16.
Berrendero S, Salido MP, Valverde A, Ferreiroa A, Pradíes G. Influence of conventional and digital intraoral impressions on the fit of CAD/CAM-fabricated all-ceramic crowns. Clin Oral Investig. 2016;20:2403-10.
Nagarkar SR, Perdigão J, Seong WJ, Theis-Mahon N. Digital versus conventional impressions for full-coverage restorations: a systematic review and meta-analysis. J Am Dent Assoc. 2018;149:139-47.e1.
Holmes JR, Bayne SC, Holland GA, Sulik WD. Considerations in measurement of marginal fit. J Prosthet Dent. 1989;62:405-8.
Neves FD, Prado CJ, Prudente MS, Carneiro TA, Zancopé K, Davi LR, et al. Micro-computed tomography evaluation of marginal fit of lithium disilicate crowns fabricated by using chairside CAD/CAM systems or the heat-pressing technique. J Prosthet Dent. 2014;112:1134-40.
Martínez-Rus F, Suárez MJ, Rivera B, Pradíes G. Evaluation of the absolute marginal discrepancy of zirconia-based ceramic copings. J Prosthet Dent. 2011;105:108-14.
Duqum IS, Brenes C, Mendonca G, Carneiro T, Cooper LF. Marginal fit evaluation of CAD/CAM all ceramic crowns obtained by two digital workflows: an in vitro study using micro-CT technology. J Prosthodont. 2019;28:1037-43.
Lee KB, Park CW, Kim KH, Kwon TY. Marginal and internal fit of all-ceramic crowns fabricated with two different CAD/CAM systems. Dent Mater J. 2008;27:422-6.
Reich S, Uhlen S, Gozdowski S, Lohbauer U. Measurement of cement thickness under lithium disilicate crowns using an impression material technique. Clin Oral Investig. 2011;15:521-6.
Mörmann WH, Bindl A, Lüthy H, Rathke A. Effects of preparation and luting system on all-ceramic computer-generated crowns. Int J Prosthodont. 1998;11:333-9.

Auteurs

Alejandro Sanchez-Lara (A)

Department of Prosthodontics, Eastman Institute for Oral Health, University of Rochester, Rochester, New York, USA.

Sherif Hosney (S)

Department of Restorative Dental Sciences, Division of Prosthodontics, University of Florida College of Dentistry, Gainesville, Florida, USA.

Evangelina Lampraki (E)

Private practice, Dubai, United Arab Emirates.

Julian Conejo (J)

Department of Preventive and Restorative Sciences, University of Pennsylvania School of Dental Medicine, Philadelphia, Pennsylvania, USA.

Markus B Blatz (MB)

Department of Preventive and Restorative Sciences, University of Pennsylvania School of Dental Medicine, Philadelphia, Pennsylvania, USA.

Abdul Basir Barmak (AB)

Division of Clinical Research and Biostatistics, Eastman Institute of Oral Health, University of Rochester Medical Center, Rochester, New York, USA.

Carlo Ercoli (C)

Departments of Prosthodontics and Periodontics, Eastman Institute for Oral Health, University of Rochester, Rochester, New York, USA.

Konstantinos Chochlidakis (K)

Department of Prosthodontics, Eastman Institute for Oral Health, University of Rochester, Rochester, New York, USA.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH