Using a poroelastodynamic model to investigate the dynamic behaviour of articular cartilage.


Journal

Computer methods and programs in biomedicine
ISSN: 1872-7565
Titre abrégé: Comput Methods Programs Biomed
Pays: Ireland
ID NLM: 8506513

Informations de publication

Date de publication:
May 2023
Historique:
received: 22 10 2022
revised: 10 03 2023
accepted: 11 03 2023
medline: 11 4 2023
pubmed: 25 3 2023
entrez: 24 3 2023
Statut: ppublish

Résumé

There is still a few studies about the poroelastic model that performed dynamic behaviour, especially for the case of the poroelastic cartilage model. Therefore, this study is aimed to use the poroelastodynamic model to simulate the dynamic behaviour of cartilage. The governing equations of the poroelastodynamic model is firstly established. The validation of the model is initialised by modifying the equations into the static poroelastic model. The modified equations are then discretised using the finite element method. Mandel's problem is used to validate the discretised equations. The numerical solution calculated using FreeFEM++ is validated with the analytical solution for the quasi-static state and compared with the results generated using COMSOL Multiphysics software. Finally, the quasi-static solution is compared with the dynamic solution to discuss the difference in pore pressure and displacement variations of the poroelastic cartilage model. The dynamic solution showed transient behaviour at the beginning of the excitation. When the compressive force acts on the cartilage, there are obvious fluctuations during the initial stage and then the dynamic numerical solution gradually approaches the quasi-static value over a period of time. The deduced results of the analytical solution were approximately the same as the numerical simulation results. This study was able to use the poroelastodynamics equation to simulate the dynamic behaviour of the poroelastic cartilage model. The comparison between the result coming from poroelastodynamics equation with that of the validated numerical solution was satisfactorily compared. The approximate similarity between the results of quasi-static and dynamic solutions underscored the importance of performing the dynamic solution for a more realistic simulation. This dynamic solution can be further used for the analysis of vibration or stress waves in future research.

Sections du résumé

BACKGROUND AND OBJECTIVE OBJECTIVE
There is still a few studies about the poroelastic model that performed dynamic behaviour, especially for the case of the poroelastic cartilage model. Therefore, this study is aimed to use the poroelastodynamic model to simulate the dynamic behaviour of cartilage.
METHODS METHODS
The governing equations of the poroelastodynamic model is firstly established. The validation of the model is initialised by modifying the equations into the static poroelastic model. The modified equations are then discretised using the finite element method. Mandel's problem is used to validate the discretised equations. The numerical solution calculated using FreeFEM++ is validated with the analytical solution for the quasi-static state and compared with the results generated using COMSOL Multiphysics software. Finally, the quasi-static solution is compared with the dynamic solution to discuss the difference in pore pressure and displacement variations of the poroelastic cartilage model.
RESULTS RESULTS
The dynamic solution showed transient behaviour at the beginning of the excitation. When the compressive force acts on the cartilage, there are obvious fluctuations during the initial stage and then the dynamic numerical solution gradually approaches the quasi-static value over a period of time. The deduced results of the analytical solution were approximately the same as the numerical simulation results.
CONCLUSION CONCLUSIONS
This study was able to use the poroelastodynamics equation to simulate the dynamic behaviour of the poroelastic cartilage model. The comparison between the result coming from poroelastodynamics equation with that of the validated numerical solution was satisfactorily compared. The approximate similarity between the results of quasi-static and dynamic solutions underscored the importance of performing the dynamic solution for a more realistic simulation. This dynamic solution can be further used for the analysis of vibration or stress waves in future research.

Identifiants

pubmed: 36963330
pii: S0169-2607(23)00147-5
doi: 10.1016/j.cmpb.2023.107481
pii:
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

107481

Informations de copyright

Copyright © 2023. Published by Elsevier B.V.

Auteurs

Dean Chou (D)

Department of Biomedical Engineering, National Cheng Kung University, Tainan City, Taiwan; Medical Device Innovation Center, National Cheng Kung University, Tainan City, Taiwan. Electronic address: dean@gs.ncku.edu.tw.

Yun-Di Li (YD)

Department of Mechanical Engineering, National Central University, Taoyuan City, Taiwan.

Zartasha Mustansar (Z)

Department of National University of Science and Technology, Islamabad, Pakistan. Electronic address: zmustansar@sines.nust.edu.pk.

Chen-Yuan Chung (CY)

Department of Mechanical Engineering, National Central University, Taoyuan City, Taiwan. Electronic address: cychung@ncu.edu.tw.

Articles similaires

Humans Meta-Analysis as Topic Sample Size Models, Statistical Computer Simulation

Hemiarthroplasty in young patients.

Hazimah Mahmud, Dong Wang, Andra Topan-Rat et al.
1.00
Humans Male Hemiarthroplasty Middle Aged Aged

High-throughput Bronchus-on-a-Chip system for modeling the human bronchus.

Akina Mori, Marjolein Vermeer, Lenie J van den Broek et al.
1.00
Humans Bronchi Lab-On-A-Chip Devices Epithelial Cells Goblet Cells
Humans Algorithms Software Artificial Intelligence Computer Simulation

Classifications MeSH