Résumé
In late 2018, the production of We conducted a prospective single centre study during February and March 2019. All patients referred for GFR measurement received both radiotracers simultaneously: Twenty-two patients were included (mean age 63.4 ± 17.5 years; 68% men). Mean urinary clearance of Urinary and plasma clearance of
Sections du résumé
BACKGROUND
BACKGROUND
In late 2018, the production of
METHODS
METHODS
We conducted a prospective single centre study during February and March 2019. All patients referred for GFR measurement received both radiotracers simultaneously:
RESULTS
RESULTS
Twenty-two patients were included (mean age 63.4 ± 17.5 years; 68% men). Mean urinary clearance of
CONCLUSIONS
CONCLUSIONS
Urinary and plasma clearance of
Identifiants
pubmed: 37093492
doi: 10.1007/s40620-023-01612-0
pii: 10.1007/s40620-023-01612-0
doi:
Substances chimiques
Technetium Tc 99m Pentetate
VW78417PU1
Pentetic Acid
7A314HQM0I
Edetic Acid
9G34HU7RV0
Technetium
7440-26-8
Chromium Radioisotopes
0
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
2457-2465Informations de copyright
© 2023. The Author(s) under exclusive licence to Italian Society of Nephrology.
Références
Levey AS (1999) A more accurate method to estimate glomerular filtration rate from serum creatinine: a new prediction equation. Ann Intern Med 130:461. https://doi.org/10.7326/0003-4819-130-6-199903160-00002
doi: 10.7326/0003-4819-130-6-199903160-00002
pubmed: 10075613
Levey AS, Stevens LA, Schmid CH, Zhang Y (Lucy), Castro AF, Feldman HI, Kusek JW, Eggers P, Van Lente F, Greene T, Coresh J, for the CKD-EPI (Chronic Kidney Disease Epidemiology Collaboration) (2009) A new equation to estimate glomerular filtration rate. Ann Intern Med 150:604. https://doi.org/10.7326/0003-4819-150-9-200905050-00006
Froissart M, Rossert J, Jacquot C, Paillard M, Houillier P (2005) Predictive performance of the modification of diet in renal disease and Cockcroft-Gault equations for estimating renal function. J Am Soc Nephrol JASN 16:763–773. https://doi.org/10.1681/ASN.2004070549
doi: 10.1681/ASN.2004070549
pubmed: 15659562
Soveri I, Berg UB, Björk J, Elinder C-G, Grubb A, Mejare I, Sterner G, Bäck S-E (2014) Measuring GFR: a systematic review. Am J Kidney Dis 64:411–424. https://doi.org/10.1053/j.ajkd.2014.04.010
doi: 10.1053/j.ajkd.2014.04.010
pubmed: 24840668
Levey AS, Inker LA (2017) Assessment of glomerular filtration rate in health and disease: a state of the art review. Clin Pharmacol Ther 102:405–419. https://doi.org/10.1002/cpt.729
doi: 10.1002/cpt.729
pubmed: 28474735
Information de sécurité - Proinuline Serb 25 %, solution inject - ANSM. https://ansm.sante.fr/informations-de-securite/proinuline-serb-25-solution-injectable-i-v-et-inutest-25-solution-injectable-i-v-laboratoires-serb . Accessed 20 Sep 2022
Bui T-V, Prot-Bertoye C, Ayari H, Baron S, Bertocchio J-P, Bureau C, Davis P, Blanchard A, Houillier P, Prie D, Lillo-Le Louet A, Courbebaisse M (2021) Safety of inulin and sinistrin: combining several sources for pharmacovigilance purposes. Front Pharmacol 12:725417. https://doi.org/10.3389/fphar.2021.725417
doi: 10.3389/fphar.2021.725417
pubmed: 34867328
pmcid: 8637630
Garnett E, Parsons V, Veall N (1967) MEasurement of glomerular filtration-rate in man using a 51Cr/Edetic-acid complex. Lancet 289:818
doi: 10.1016/S0140-6736(67)92781-X
Favre HR, Wing A (1968) SIMultaneous 51Cr edetic acid, inulin, and endogenous clearances in 20 patients with renal disease. Br Med J 1:84–86
doi: 10.1136/bmj.1.5584.84
pubmed: 4965265
pmcid: 1984743
Medeiros FSR, Sapienza MT, Prado ES, Agena F, Shimizu MHM, Lemos FBC, Buchpiguel CA, Ianhez LE, David-Neto E (2009) Validation of plasma clearance of 51Cr-EDTA in adult renal transplant recipients: comparison with inulin renal clearance. Transpl Int 22:323–331. https://doi.org/10.1111/j.1432-2277.2008.00799.x
doi: 10.1111/j.1432-2277.2008.00799.x
pubmed: 19055616
(2008) Guide pour la rédaction de protocoles pour les mesures de clairances rénales glomérulaires. Médecine Nucl 32:635–642. https://doi.org/10.1016/j.mednuc.2008.10.005
SUMMARY OF PRODUCT CHARACTERISTICS. https://perlamar.ie/wp-content/uploads/IE-4362-Technescan-DTPA-SPC-Feb16.pdf . Accessed 21 Dec 2015
Vidal-Petiot E, Courbebaisse M, Livrozet M, Corrégé G, Rusu T, Montravers F, Baron S, Dupont L, Balouzet C, Smadja C, Leygnac S, Pariscoat G, Rose J, Rouzet F, Houillier P, Haymann J-P, Flamant M (2021) Comparison of 51Cr-EDTA and 99mTc-DTPA for glomerular filtration rate measurement. J Nephrol 34:729–737. https://doi.org/10.1007/s40620-020-00932-9
doi: 10.1007/s40620-020-00932-9
pubmed: 33661505
Bröchner-Mortensen J, Giese J, Rossing N (1969) Renal inulin clearance versus total plasma clearance of 51Cr-EDTA. Scand J Clin Lab Invest 23:301–305. https://doi.org/10.3109/00365516909081695
doi: 10.3109/00365516909081695
pubmed: 4986443
Gaillard F, Flamant M, Lemoine S, Baron S, Timsit M-O, Eladari D, Fournier C, Prot-Bertoye C, Bertocchio J-P, Vidal-Petiot E, Lamhaut L, Morelon E, Péraldi M-N, Vrtovsnik F, Friedlander G, Méjean A, Houillier P, Legendre C, Courbebaisse M (2016) Estimated or measured GFR in living kidney donors work-up? Am J Transplant Off J Am Soc Transplant Am Soc Transpl Surg 16:3024–3032. https://doi.org/10.1111/ajt.13908
doi: 10.1111/ajt.13908
Rouanne M, Gaillard F, Meunier ME, Soorojebally Y, Phan H, Slimani-Thevenet H, Jannot A-S, Neuzillet Y, Friedlander G, Froissart M, Botto H, Houillier P, Lebret T, Courbebaisse M (2020) Measured glomerular filtration rate (GFR) significantly and rapidly decreases after radical cystectomy for bladder cancer. Sci Rep 10:16145. https://doi.org/10.1038/s41598-020-73191-0
doi: 10.1038/s41598-020-73191-0
pubmed: 32999403
pmcid: 7528003
Stevens PE, Levin A, Kidney Disease: Improving Global Outcomes Chronic Kidney Disease Guideline Development Work Group Members (2013) Evaluation and management of chronic kidney disease: synopsis of the kidney disease: improving global outcomes 2012 clinical practice guideline. Ann Intern Med 158:825–830. https://doi.org/10.7326/0003-4819-158-11-201306040-00007
Berger EY, Farber SJ, Earle DP, Jackenthal R (1948) Comparison of the constant infusion and urine collection techniques for the measurement of renal function. J Clin Invest 27:710–716. https://doi.org/10.1172/JCI102020
doi: 10.1172/JCI102020
pubmed: 18121572
pmcid: 439547
Cole BR, Giangiacomo J, Ingelfinger JR, Robson AM (1972) Measurement of renal function without urine collection. A critical evaluation of the constant-infusion technic for determination of inulin and para-aminohippurate. N Engl J Med 287:1109–1114. https://doi.org/10.1056/NEJM197211302872202
doi: 10.1056/NEJM197211302872202
pubmed: 5082190
Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet Lond Engl 1:307–310
doi: 10.1016/S0140-6736(86)90837-8
Rehling M, Møller ML, Thamdrup B, Lund JO, Trap-Jensen J (1984) Simultaneous measurement of renal clearance and plasma clearance of 99mTc-labelled Diethylenetriaminepenta-acetate, 51Cr-labelled Ethylenediaminetetra-acetate and inulin in man. Clin Sci 66:613–619. https://doi.org/10.1042/cs0660613
doi: 10.1042/cs0660613
Andersen TB, Jødal L, Nielsen NS, Petersen LJ (2019) Comparison of simultaneous plasma clearance of
doi: 10.1080/00365513.2019.1658217
pubmed: 31502901
Simonsen JA, Thilsing-Hansen K, Høilund-Carlsen PF, Gerke O, Andersen TL (2020) Glomerular filtration rate: comparison of simultaneous plasma clearance of 99mTc-DTPA and 51Cr-EDTA revisited. Scand J Clin Lab Invest 80:408–411. https://doi.org/10.1080/00365513.2020.1759138
doi: 10.1080/00365513.2020.1759138
pubmed: 32362172
Gaspari F, Perico N, Matalone M, Signorini O, Azzollini N, Mister M, Remuzzi G (1998) Precision of plasma clearance of iohexol for estimation of GFR in patients with renal disease. J Am Soc Nephrol JASN 9:310–313. https://doi.org/10.1681/ASN.V92310
doi: 10.1681/ASN.V92310
pubmed: 9527409
Delanaye P, Ebert N, Melsom T, Gaspari F, Mariat C, Cavalier E, Björk J, Christensson A, Nyman U, Porrini E, Remuzzi G, Ruggenenti P, Schaeffner E, Soveri I, Sterner G, Eriksen BO, Bäck S-E (2016) Iohexol plasma clearance for measuring glomerular filtration rate in clinical practice and research: a review. Part 1: how to measure glomerular filtration rate with iohexol? Clin Kidney J 9:682–699. https://doi.org/10.1093/ckj/sfw070
doi: 10.1093/ckj/sfw070
pubmed: 27679715
pmcid: 5036902