Usability Study on Patient Monitoring Systems: An Evaluation of a User Interface Based on User Experience and Preference.


Journal

Medical science monitor : international medical journal of experimental and clinical research
ISSN: 1643-3750
Titre abrégé: Med Sci Monit
Pays: United States
ID NLM: 9609063

Informations de publication

Date de publication:
04 Jun 2023
Historique:
medline: 5 6 2023
pubmed: 4 6 2023
entrez: 4 6 2023
Statut: epublish

Résumé

BACKGROUND The poor ergonomic design of patient monitoring systems can cause user errors and patient harm. This paper presents the results of a comparative usability study based on user experience and the results of a user preference survey. MATERIAL AND METHODS We conducted a usability study of 3 patient monitoring systems: Mediana M50, Philips IntelliVue MP70, and Philips IntelliVue MX700. Thirty-nine Coronary Care Unit nurses and 19 Pulmonology and Allergy Care Unit nurses participated in this usability study. User experience was assessed with the Post-Study System Usability Questionnaire and the National Aeronautics and Space Administration Task Load Index. A user preference survey was conducted to evaluate the subjective medical device design preferences for the M50 system's user interface. RESULTS Nurses from the Coronary Care Unit recognized a higher system usability for the MP70 than the M50 (P=0.001) system, and a lower workload for the MP70 compared with the M50 (P=0.005) system. There was no significant (P>0.05) difference in perceived system usability and workload between the M50 and MX700 systems for the nurses from the Pulmonology and Allergy Care Unit. Nurses preferred to activate the arrhythmia alarms except for the ST alarms and missed the beat alarm. They also preferred having a wave freeze function, standby mode, and early warning scoring function, which provides a signal for a patient's deterioration in health. CONCLUSIONS The study provides valuable data on a user interface evaluation based on user experience and preference. The outcome of this study will be helpful for designing next-generation patient monitors with improved patient safety.

Identifiants

pubmed: 37270667
pii: 938570
doi: 10.12659/MSM.938570
pmc: PMC10249438
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

e938570

Références

Anesth Analg. 2013 Aug;117(2):380-91
pubmed: 23780423
Curr Opin Crit Care. 2002 Aug;8(4):316-20
pubmed: 12386492
Med Sci Monit. 2018 Dec 15;24:9090-9101
pubmed: 30552313
Appl Ergon. 2018 Nov;73:22-32
pubmed: 30098639
Radiother Oncol. 2006 Sep;80(3):275-81
pubmed: 16904785
Sensors (Basel). 2020 Mar 24;20(6):
pubmed: 32213969
JMIR Hum Factors. 2020 Jul 3;7(3):e15052
pubmed: 32618574
Crit Care Med. 2004 Feb;32(2):428-32
pubmed: 14758159
Anesth Analg. 2012 Sep;115(3):588-94
pubmed: 22696607
J Clin Monit Comput. 2008 Feb;22(1):45-66
pubmed: 18064532
J Am Med Inform Assoc. 2006 Nov-Dec;13(6):635-42
pubmed: 16929038
Jt Comm J Qual Saf. 2004 Aug;30(8):455-9
pubmed: 15357136
Int J Med Inform. 2008 Nov;77(11):765-77
pubmed: 18639487
Jt Comm J Qual Saf. 2004 Dec;30(12):689-95
pubmed: 15646102
Qual Saf Health Care. 2006 Dec;15 Suppl 1:i59-65
pubmed: 17142611
Int J Telerehabil. 2012 Apr 13;4(1):15-24
pubmed: 25945193
Crit Care Med. 2003 Mar;31(3):992-3
pubmed: 12627029
Respir Care. 2016 May;61(5):632-9
pubmed: 27121622
Crit Care Med. 2005 Aug;33(8):1694-700
pubmed: 16096443
Med Sci Monit. 2019 Jan 20;25:578-589
pubmed: 30661077
Crit Care. 2016 Aug 20;20:263
pubmed: 27542352
Radiol Med. 1998 Nov;96(5):485-91
pubmed: 10051873
J Med Internet Res. 2021 May 28;23(5):e26494
pubmed: 34047701

Auteurs

Yourim Kim (Y)

Department Medical Device Engineering & Management, Yonsei University College of Medicine, Seoul, South Korea.

Jimin Son (J)

Department Medical Device Engineering & Management, Yonsei University College of Medicine, Seoul, South Korea.

Wonseuk Jang (W)

Department Medical Device Engineering & Management, Yonsei University College of Medicine, Seoul, South Korea.
Medical Device Usability Research Center, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, South Korea.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH