Attempt to Make the Upper-Limb Item of Objective Fugl-Meyer Assessment Using 9-Axis Motion Sensors.
Fugl–Meyer Assessment
IMU
VICON
upper limb
Journal
Sensors (Basel, Switzerland)
ISSN: 1424-8220
Titre abrégé: Sensors (Basel)
Pays: Switzerland
ID NLM: 101204366
Informations de publication
Date de publication:
30 May 2023
30 May 2023
Historique:
received:
28
03
2023
revised:
11
05
2023
accepted:
28
05
2023
medline:
12
6
2023
pubmed:
10
6
2023
entrez:
10
6
2023
Statut:
epublish
Résumé
The Fugl-Meyer Assessment (FMA) has been used as a functional assessment of upper-limb function in stroke patients. This study aimed to create a more objective and standardized evaluation based on an FMA of the upper-limb items. A total of 30 first-ever stroke patients (65.3 ± 10.3 years old) and 15 healthy participants (35.4 ± 13.4 years old) admitted to Itami Kousei Neurosurgical Hospital were included. A nine-axis motion sensor was attached to the participants, and the joint angles of 17 upper-limb items (excluding fingers) and 23 FMA upper-limb items (excluding reflexes and fingers) were measured. From the measurement results, we analyzed the time-series data of each movement and obtained the correlation between the joint angles of each part. Discriminant analysis showed that 17 and 6 items had a concordance rate of ≥80% (80.0~95.6%) and <80% (64.4~75.6%), respectively. In the multiple regression analysis of continuous variables of FMA, a good regression model was obtained to predict the FMA with three to five joint angles. The discriminant analysis for 17 evaluation items suggests the possibility of roughly calculating FMA scores from joint angles.
Identifiants
pubmed: 37299941
pii: s23115213
doi: 10.3390/s23115213
pmc: PMC10255665
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Subventions
Organisme : Teijin Pharma Limited based on a contract research agreement
Références
Neurorehabil Neural Repair. 2002 Sep;16(3):232-40
pubmed: 12234086
Phys Ther. 1983 Oct;63(10):1606-10
pubmed: 6622535
Clin Rehabil. 2004 Jun;18(4):391-7
pubmed: 15180122
Gait Posture. 2014;39(1):593-8
pubmed: 24269523
J Manipulative Physiol Ther. 2019 Jan;42(1):75-81
pubmed: 31054596
Phys Ther. 1993 Jul;73(7):447-54
pubmed: 8316578
Arch Phys Med Rehabil. 1994 Nov;75(11):1206-12
pubmed: 7979930
PLoS One. 2016 Jul 01;11(7):e0158640
pubmed: 27367518
Annu Int Conf IEEE Eng Med Biol Soc. 2011;2011:5839-42
pubmed: 22255667
Stroke. 2011 Jun;42(6):1787-94
pubmed: 21566236
Scand J Rehabil Med. 1975;7(1):13-31
pubmed: 1135616
Sensors (Basel). 2015 Aug 14;15(8):20097-114
pubmed: 26287206
Stroke. 2011 Feb;42(2):427-32
pubmed: 21164120
PLoS One. 2016 May 06;11(5):e0154792
pubmed: 27152853
Stroke. 2001 Jan;32(1):107-12
pubmed: 11136923
Stroke. 2016 Jun;47(6):e98-e169
pubmed: 27145936
Stroke. 1990 May;21(5):731-9
pubmed: 2339453
Comput Methods Programs Biomed. 2016 May;128:100-10
pubmed: 27040835
IEEE Trans Neural Syst Rehabil Eng. 2018 Jan;26(1):125-134
pubmed: 28952944