Thyroglobulin immunoassay with a fully automated pretreatment process provides accurate thyroglobulin values in anti-thyroglobulin antibody positive specimens.
Immunoassay
LC-MS/MS
Pretreatment
Tg-TgAb complexes
Thyroglobulin
Journal
Clinical biochemistry
ISSN: 1873-2933
Titre abrégé: Clin Biochem
Pays: United States
ID NLM: 0133660
Informations de publication
Date de publication:
Aug 2023
Aug 2023
Historique:
received:
22
02
2023
revised:
08
06
2023
accepted:
10
06
2023
medline:
7
8
2023
pubmed:
18
6
2023
entrez:
17
6
2023
Statut:
ppublish
Résumé
Human thyroglobulin (Tg) is widely used as a tumor marker for recurrence and metastasis of differentiated thyroid cancer (DTC). Currently, serum Tg values are measured using second-generation sandwich immunoassays (2nd-IMA). However, interference by endogenous autoantibodies to thyroglobulin (TgAbs) can lead to false-negative results or falsely low Tg values. Here, we describe a new Tg assay using the immunoassay for total antigen including complex via pretreatment (iTACT) method to prevent TgAb interference and compare it with 2nd-IMA. Tg values were evaluated by three assays: iTACT Tg, Elecsys Tg-II, which is a 2nd-IMA, and LC-MS/MS (Liquid chromatography tandem-mass spectrometry). The ratio of Tg values between each assay was then compared to the Tg value by LC-MS/MS and TgAb titer. Tg immunoreactivity was analyzed by size-exclusion chromatography. Correlation between iTACT Tg and LC-MS/MS using TgAb-positive specimens was good: Passing-Bablok regression with iTACT Tg = 1.084 × LC-MS/MS + 0.831. Correlation between 2nd-IMA and LC-MS/MS showed a relatively lower slope: 2nd-IMA = 0.747 × LC-MS/MS - 0.518. Thus, Tg values determined by iTACT Tg are equivalent to those of LC-MS/MS regardless of TgAb titer, whereas 2nd-IMA gave lower Tg values due to TgAb interference. Tg-TgAb complexes of various molecular weights were verified by size-exclusion chromatography. Tg values measured by 2nd-IMA fluctuated depending on the molecular weight of the Tg-TgAb complexes, whereas iTACT Tg accurately quantified Tg values regardless of the size of the Tg-TgAb complexes. Tg values in TgAb-positive specimens were accurately determined by iTACT Tg. TgAb-positive specimens contain Tg-TgAb complexes of various molecular weights that interfere with Tg value determination by 2nd-IMA, whereas iTACT Tg is unaffected by the presence of Tg-TgAb complexes.
Identifiants
pubmed: 37330000
pii: S0009-9120(23)00126-1
doi: 10.1016/j.clinbiochem.2023.110598
pii:
doi:
Substances chimiques
anti-thyroglobulin
0
Autoantibodies
0
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
110598Informations de copyright
Copyright © 2023 The Author(s). Published by Elsevier Inc. All rights reserved.
Déclaration de conflit d'intérêts
Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.