Thyroglobulin immunoassay with a fully automated pretreatment process provides accurate thyroglobulin values in anti-thyroglobulin antibody positive specimens.


Journal

Clinical biochemistry
ISSN: 1873-2933
Titre abrégé: Clin Biochem
Pays: United States
ID NLM: 0133660

Informations de publication

Date de publication:
Aug 2023
Historique:
received: 22 02 2023
revised: 08 06 2023
accepted: 10 06 2023
medline: 7 8 2023
pubmed: 18 6 2023
entrez: 17 6 2023
Statut: ppublish

Résumé

Human thyroglobulin (Tg) is widely used as a tumor marker for recurrence and metastasis of differentiated thyroid cancer (DTC). Currently, serum Tg values are measured using second-generation sandwich immunoassays (2nd-IMA). However, interference by endogenous autoantibodies to thyroglobulin (TgAbs) can lead to false-negative results or falsely low Tg values. Here, we describe a new Tg assay using the immunoassay for total antigen including complex via pretreatment (iTACT) method to prevent TgAb interference and compare it with 2nd-IMA. Tg values were evaluated by three assays: iTACT Tg, Elecsys Tg-II, which is a 2nd-IMA, and LC-MS/MS (Liquid chromatography tandem-mass spectrometry). The ratio of Tg values between each assay was then compared to the Tg value by LC-MS/MS and TgAb titer. Tg immunoreactivity was analyzed by size-exclusion chromatography. Correlation between iTACT Tg and LC-MS/MS using TgAb-positive specimens was good: Passing-Bablok regression with iTACT Tg = 1.084 × LC-MS/MS + 0.831. Correlation between 2nd-IMA and LC-MS/MS showed a relatively lower slope: 2nd-IMA = 0.747 × LC-MS/MS - 0.518. Thus, Tg values determined by iTACT Tg are equivalent to those of LC-MS/MS regardless of TgAb titer, whereas 2nd-IMA gave lower Tg values due to TgAb interference. Tg-TgAb complexes of various molecular weights were verified by size-exclusion chromatography. Tg values measured by 2nd-IMA fluctuated depending on the molecular weight of the Tg-TgAb complexes, whereas iTACT Tg accurately quantified Tg values regardless of the size of the Tg-TgAb complexes. Tg values in TgAb-positive specimens were accurately determined by iTACT Tg. TgAb-positive specimens contain Tg-TgAb complexes of various molecular weights that interfere with Tg value determination by 2nd-IMA, whereas iTACT Tg is unaffected by the presence of Tg-TgAb complexes.

Identifiants

pubmed: 37330000
pii: S0009-9120(23)00126-1
doi: 10.1016/j.clinbiochem.2023.110598
pii:
doi:

Substances chimiques

anti-thyroglobulin 0
Autoantibodies 0

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

110598

Informations de copyright

Copyright © 2023 The Author(s). Published by Elsevier Inc. All rights reserved.

Déclaration de conflit d'intérêts

Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

Auteurs

Yoshiyuki Kitamura (Y)

Development Division, FUJIREBIO INC., Tokyo, Japan.

Sho Narita (S)

Development Division, FUJIREBIO INC., Tokyo, Japan.

Shintaro Yagi (S)

Development Division, Advanced Life Science Institute, Inc., Tokyo, Japan.

Katsumi Aoyagi (K)

Development Division, FUJIREBIO INC., Tokyo, Japan; Development Division, Advanced Life Science Institute, Inc., Tokyo, Japan. Electronic address: katsumi.aoyagi@hugp.com.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH