Initial clinical experience with the pulsed solid-state thulium YAG laser from Dornier during RIRS: first 25 cases.
Laser
Lithotripsy
Thulium YAG
Ureteroscopy
Volume
Journal
World journal of urology
ISSN: 1433-8726
Titre abrégé: World J Urol
Pays: Germany
ID NLM: 8307716
Informations de publication
Date de publication:
Aug 2023
Aug 2023
Historique:
received:
24
05
2023
accepted:
07
06
2023
medline:
11
8
2023
pubmed:
7
7
2023
entrez:
6
7
2023
Statut:
ppublish
Résumé
Holmium:yttrium-aluminium-garnet (Ho:YAG) and thulium fiber (TFL) lasers are currently the two laser sources recommended for endocorporeal laser lithotripsy (ELL). Recently, the pulsed-thulium:YAG (Tm:YAG) laser was also proposed for ELL, as an answer to both Ho:YAG and TFL limitations. We aimed to evaluate the efficiency, safety, and laser settings of Tm:YAG laser in ELL during retrograde intrarenal surgery (RIRS). A prospective study of the first 25 patients with ureteral and renal stones who underwent RIRS using the Thulio (pulsed-Tm:YAG, Dornier©, Germany) was performed in a single center. 272 µm laser fibers were used. Stone size, stone density, laser-on time (LOT) and laser settings were recorded. We also assessed the ablation speed (mm A total of 25 patients were analyzed (Table 1). The median (IQR) age was 55 (44-72) years old. Median (IQR) stone volume was 2849 (916-9153)mm The pulsed-Tm:YAG laser is a safe and effective laser source for lithotripsy during RIRS, using low pulse energy and low pulse frequency.
Identifiants
pubmed: 37414942
doi: 10.1007/s00345-023-04501-0
pii: 10.1007/s00345-023-04501-0
doi:
Substances chimiques
Thulium
8RKC5ATI4P
Holmium
W1XX32SQN1
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
2119-2125Informations de copyright
© 2023. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.
Références
Traxer O, Keller EX (2019) Thulium fiber laser: the new player for kidney stone treatment? A comparison with Holmium:YAG laser. World J Urol. 38:1883
doi: 10.1007/s00345-019-02654-5
pubmed: 30729311
pmcid: 7363731
Johnson DE, Cromeens DM, Price RE (1992) Use of the holmium:YAG laser in urology. Lasers Surg Med 12(4):353–363
doi: 10.1002/lsm.1900120402
pubmed: 1386643
Gupta PK (2007) Is the holmium:YAG laser the best intracorporeal lithotripter for the ureter? A 3-year retrospective study. J Endourol Mars 21(3):305–309
doi: 10.1089/end.2006.0247
Urofrance | Recommandations de bonne pratique pour la prise en charge des calculs et de la lithiase urinaires: diagnostic, traitement, suivi et prévention secondaire - Argumentaire - Urofrance [Internet]. [cité 17 nov 2022]. Disponible sur: https://www.urofrance.org/recommandation/recommandations-de-bonne-pratique-pour-la-prise-en-charge-des-calculs-et-de-la-lithiase-urinaires-diagnostic-traitement-suivi-et-prevention-secondaire-argumentaire/
Blackmon RL, Irby PB, Fried NM (2011) Comparison of holmium:YAG and thulium fiber laser lithotripsy: ablation thresholds, ablation rates, and retropulsion effects. J Biomed Opt juill 16(7):071403
doi: 10.1117/1.3564884
Ventimiglia E, Doizi S, Kovalenko A, Andreeva V, Traxer O (2020) Effect of temporal pulse shape on urinary stone phantom retropulsion rate and ablation efficiency using holmium:YAG and super pulse thulium fiber lasers. BJU Int. 126:159
doi: 10.1111/bju.15079
pubmed: 32277557
Petzold R, Miernik A, Suarez-Ibarrola R (2021) In vitro dusting performance of a new solid state thulium laser compared to holmium laser lithotripsy. J Endourol févr 35(2):221–225
doi: 10.1089/end.2020.0525
Petzold R, Miernik A, Suarez-Ibarrola R (2021) Retropulsion force in laser lithotripsy-an in vitro study comparing a Holmium device to a novel pulsed solid-state thulium laser. World J Urol. 39:3651
doi: 10.1007/s00345-021-03668-8
pubmed: 33758959
pmcid: 8510939
Petzold R, Suarez-Ibarrola R, Miernik A (2021) Temperature assessment of a novel pulsed thulium solid-state laser compared with a holmium:yttrium-aluminum-garnet laser. J Endourol juin 35(6):853–859
doi: 10.1089/end.2020.0803
Kraft L, Yilmaz M, Petzold R, Gratzke C, Suarez-Ibarrola R, Miernik A (2022) Dusting efficiency of a novel pulsed thulium: yttrium aluminum garnet laser vs a thulium fiber laser. J Endourol févr 36(2):259–265
doi: 10.1089/end.2021.0441
Kraft L, Petzold R, Suarez-Ibarrola R, Miernik A (2022) In vitro fragmentation performance of a novel, pulsed Thulium solid-state laser compared to a Thulium fibre laser and standard Ho:YAG laser. Lasers Med Sci avr 37(3):2071–2078
doi: 10.1007/s10103-021-03495-8
Brisbane W, Bailey MR, Sorensen MD (2016) An overview of kidney stone imaging techniques. Nat Rev Urol 13(11):654–662
doi: 10.1038/nrurol.2016.154
pubmed: 27578040
pmcid: 5443345
Fedorov A, Beichel R, Kalpathy-Cramer J, Finet J, Fillion-Robin JC, Pujol S et al (2012) 3D Slicer as an image computing platform for the quantitative imaging network. Magn Reson Imaging 30(9):1323–1341
doi: 10.1016/j.mri.2012.05.001
pubmed: 22770690
pmcid: 3466397
Panthier F, Traxer O, Yonneau L, Lebret T, Berthe L, Illoul L et al (2021) Evaluation of a free 3D software for kidney stones’ surgical planning: kidney stone calculator a pilot study. World J Urol. 39:3607
doi: 10.1007/s00345-021-03671-z
pubmed: 33779821
pmcid: 8006641
Dindo D, Demartines N, Clavien PA (2004) Classification of surgical complications: a new proposal with evaluation in a cohort of 6336 patients and results of a survey. Ann Surg août 240(2):205–213
doi: 10.1097/01.sla.0000133083.54934.ae
Thulio® [Internet]. Dornier MedTech. [cité 19 mai 2023]. Disponible sur: https://www.dornier.com/products-item/dornier-thulio/
Sierra A, Corrales M, Piñero A, Traxer O (2022) Thulium fiber laser pre-settings during ureterorenoscopy: Twitter’s experts’ recommendations. World J Urol. 40:1529
doi: 10.1007/s00345-022-03966-9
pubmed: 35246704
Sierra A, Corrales M, Piñero A, Kolvatzis M, Somani B, Traxer O (2022) Glossary of pre-settings given by laser companies: no consensus! World J Urol 40(9):2313–2321
doi: 10.1007/s00345-022-04090-4
pubmed: 35933626
Weiss B, Shah O (2016) Evaluation of dusting versus basketing—can new technologies improve stone-free rates? Nat Rev Urol 13(12):726–733
doi: 10.1038/nrurol.2016.172
pubmed: 27698400
Keller EX, De Coninck V, Doizi S, Daudon M, Traxer O (2020) What is the exact definition of stone dust? An in vitro evaluation. World J Urol. 39:187
doi: 10.1007/s00345-020-03178-z
pubmed: 32270283
Ventimiglia E, Pauchard F, Gorgen ARH, Panthier F, Doizi S, Traxer O (2020) How do we assess the efficacy of Ho:YAG low-power laser lithotripsy for the treatment of upper tract urinary stones? Introducing the Joules/mm3 and laser activity concepts. World J Urol. 39:891
doi: 10.1007/s00345-020-03241-9
pubmed: 32462304
Petzold R, Suarez-Ibarrola R, Miernik A (2021) Gas bubble anatomy during laser lithotripsy: an experimental in vitro study of a pulsed solid-state tm:yag and ho:yag device. J Endourol juill 35(7):1051–1057
doi: 10.1089/end.2020.0526
Panthier F, Doizi S, Gorny C, Berthe L, Traxer O (2020) Impact of laser fiber diameter and irrigation fluids on induced bubble stream dynamics with superpulsed thulium fiber laser : an in vitro study. J Endourol. 35:1883
doi: 10.1089/end.2020.0766
pubmed: 33050715
Hardy LA, Kennedy JD, Wilson CR, Irby PB, Fried NM (2017) Analysis of thulium fiber laser induced bubble dynamics for ablation of kidney stones. J Biophotonics 10(10):1240–1249
doi: 10.1002/jbio.201600010
pubmed: 27507305
Ulvik Ø, Æsøy MS, Juliebø-Jones P, Gjengstø P, Beisland C. Thulium Fibre Laser versus Holmium:YAG for Ureteroscopic Lithotripsy: Outcomes from a Prospective Randomised Clinical Trial. Eur Urol [Internet]. 14 mars 2022 [cité 16 mars 2022];0(0). Disponible sur: https://www.europeanurology.com/article/S0302-2838(22)01669-4/fulltext
Panthier F, Doizi S, Lapouge P, Chaussain C, Kogane N, Berthe L et al (2020) Comparison of the ablation rates, fissures and fragments produced with 150 µm and 272 µm laser fibers with superpulsed thulium fiber laser: an in vitro study. World J Urol. 39:1683
doi: 10.1007/s00345-020-03186-z
pubmed: 32253581
Sierra A, Corrales M, Kolvatzis M, Traxer O (2022) Initial clinical experience with the thulium fiber laser from Quanta System: First 50 reported cases. World J Urol 40(10):2549–2553
doi: 10.1007/s00345-022-04096-y
pubmed: 35861860
Corrales M, Traxer O (2021) Initial clinical experience with the new thulium fiber laser: first 50 cases. World J Urol. 39:3945
doi: 10.1007/s00345-021-03616-6
pubmed: 33590280
Professionals SO. EAU Guidelines: Urolithiasis [Internet]. Uroweb. [cité 21 sept 2020]. Disponible sur: https://uroweb.org/guideline/urolithiasis/
Louters MM, Dau JJ, Hall TL, Ghani KR, Roberts WW (2022) Laser operator duty cycle effect on temperature and thermal dose: in-vitro study. World J Urol 40(6):1575–1580
doi: 10.1007/s00345-022-03967-8
pubmed: 35220474