Percutaneous VA-ECMO from Cannulation to Decannulation: Novel Use of a Vascular Closure Device in Pediatrics.
ECMO decannulation
MANTA device
Perclose ProGlide device
Journal
Pediatric cardiology
ISSN: 1432-1971
Titre abrégé: Pediatr Cardiol
Pays: United States
ID NLM: 8003849
Informations de publication
Date de publication:
Oct 2023
Oct 2023
Historique:
received:
04
04
2023
accepted:
26
06
2023
medline:
18
8
2023
pubmed:
7
7
2023
entrez:
7
7
2023
Statut:
ppublish
Résumé
VA-ECMO can be lifesaving in cardiogenic shock in children. While surgical vascular repair is the current standard of care for decannulation, it comes with notable risks. We present a series of eight patients who underwent decannulation with a collagen plug-based vascular closure device (MANTA) for the common femoral artery. Seven of the patients were successfully decannulated without access site-related vascular complications. One required conversion to surgical cut-down with arterial repair due to device failure. This series demonstrates the successful use of the MANTA device in percutaneous VA-ECMO decannulation in the pediatric population, while highlighting potential technical challenges for success.
Identifiants
pubmed: 37418147
doi: 10.1007/s00246-023-03222-w
pii: 10.1007/s00246-023-03222-w
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
1623-1628Informations de copyright
© 2023. The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature.
Références
Halim J, Missault L, Lycke M et al (2020) Assessment of the MANTA closure device in transfemoral transcatheter aortic valve replacement: a single-centre observational study. Neth Heart J 28(12):639–644
doi: 10.1007/s12471-020-01465-3
pubmed: 32720122
pmcid: 7683762
Majunke N, Mangner N, Linke A et al (2016) Comparison of percutaneous closure versus surgical femoral cutdown for decannulation of large-sized arterial and venous access sites in adults after successful weaning of veno-arterial extracorporeal membrane oxygenation. J Invasive Cardiol 28(10):415–419
pubmed: 27705891
Góreczny S, McLennan D, Morgan GJ (2019) Accessing extracorporeal membrane oxygenation circuits to perform emergent interventional cardiac catheterisation. Cardiol Young 29(10):1290–1293
doi: 10.1017/S1047951119001446
pubmed: 31511102
Hassan MF, Lawrence M, Lee D et al (2020) Simplified percutaneous VA ECMO decannulation using the MANTA vascular closure device: Initial US experience. J Card Surg 35(1):217–221
doi: 10.1111/jocs.14308
pubmed: 31899831
Montero-Cabezas JM, van der Meer RW, van der Kley F et al (2019) Percutaneous decannulation of femoral venoarterial ECMO cannulas using MANTA vascular closure device. Can J Cardiol 35(6):796.e9-796.e11
doi: 10.1016/j.cjca.2019.02.010
pubmed: 31151721
Moccetti F, Brinkert M, Seelos R et al (2019) Insights from a multidisciplinary introduction of the MANTA vascular closure device. JACC Cardiovasc Interv 12(17):1730–1736
doi: 10.1016/j.jcin.2019.06.049
pubmed: 31488301
Van Mieghem NM, Latib A, van der Heyden J et al (2017) Percutaneous plug-based arteriotomy closure device for large-bore access: a multicenter prospective study. JACC Cardiovasc Interv 10(6):613–619
doi: 10.1016/j.jcin.2016.12.277
pubmed: 28335899
Nuis RJ, Wood D, Kroon H et al (2022) Frequency, impact, and predictors of access complications with plug-based large-bore arteriotomy closure - a patient-level meta-analysis. Cardiovasc Revasc Med 34:69–74
doi: 10.1016/j.carrev.2021.02.017
pubmed: 33612412
Wood DA, Krajcer Z, Sathananthan J et al (2019) Pivotal clinical study to evaluate the safety and effectiveness of the MANTA percutaneous vascular closure device. Circ Cardiovasc Interv 12(7):e007258
doi: 10.1161/CIRCINTERVENTIONS.119.007258
pubmed: 31296082
Bemtgen X, Heidt T, Zotzmann V et al (2020) Venoarterial extracorporeal membrane oxygenation decannulation using the novel MANTA vascular closure device. Eur Heart J Acute Cardiovasc Care 9(4):342–347
doi: 10.1177/2048872620918707
pubmed: 32363881
Miyashita H, Moriyama N, Laine M (2022) Incidence and predictors of access site vascular complications following ultrasound-guided MANTA closure deployment. J Endovasc Ther 29(4):576–585
doi: 10.1177/15266028211059446
pubmed: 34852659
van Wiechen MP, Kroon H, Hokken TW et al (2021) Vascular complications with a plug-based vascular closure device after transcatheter aortic valve replacement: predictors and bail-outs. Catheter Cardiovasc Interv 98(5):E737–E745
doi: 10.1002/ccd.29506
pubmed: 33533544
pmcid: 9292646
Moriyama N, Dahlbacka S, Vähäsilta T et al (2019) The efficacy of the ultrasound-navigated MANTA deployment following transfemoral transcatheter aortic valve replacement. JACC Cardiovasc Interv 12(24):2564–2566
doi: 10.1016/j.jcin.2019.09.018
pubmed: 31857032
Dahlbacka S, Vähäsilta T, Moriyama N et al (2020) Ultrasound-navigated manta deployment after removal of extracorporeal membrane oxygenation cannula. Ann Thorac Surg 110(4):e307–e309
doi: 10.1016/j.athoracsur.2020.01.064
pubmed: 32145194
Shah A, Ghoreishi M, Taylor BS et al (2020) Complete percutaneous decannulation from femoral venoarterial extracorporeal membrane oxygenation. JTCVS Tech 21(6):75–81
Biancari F, Romppanen H, Savontaus M et al (2018) MANTA versus ProGlide vascular closure devices in transfemoral transcatheter aortic valve implantation. Int J Cardiol 15(263):29–31
doi: 10.1016/j.ijcard.2018.04.065