Department of Cardiology, Karolinska University Hospital, Stockholm, Sweden; Department of Molecular Medicine and Surgery, Karolinska Institutet, Stockholm, Sweden. Electronic address: mikael.kastengren@sll.se.
Publications dans "Dispositifs de fermeture vasculaire" :
Department of Molecular Medicine and Surgery, Karolinska Institutet, Stockholm, Sweden; Department of Cardiothoracic Surgery, Karolinska Institutet, Stockholm, Sweden.
Publications dans "Dispositifs de fermeture vasculaire" :
Division of Vascular and Interventional Radiology, Department of Medical Imaging, Toronto General Hospital, University of Toronto, Toronto, ON, Canada.
Publications dans "Dispositifs de fermeture vasculaire" :
Division of Vascular and Interventional Radiology, Department of Medical Imaging, Toronto General Hospital, University of Toronto, Toronto, ON, Canada.
Publications dans "Dispositifs de fermeture vasculaire" :
Division of Vascular and Interventional Radiology, Department of Medical Imaging, Toronto General Hospital, University of Toronto, Toronto, ON, Canada.
Publications dans "Dispositifs de fermeture vasculaire" :
Department of Molecular Medicine and Surgery, Karolinska Institutet, Stockholm, Sweden; Department of Cardiothoracic Surgery, Karolinska Institutet, Stockholm, Sweden.
Publications dans "Dispositifs de fermeture vasculaire" :
Department of Molecular Medicine and Surgery, Karolinska Institutet, Stockholm, Sweden; Department of Cardiothoracic Surgery, Karolinska Institutet, Stockholm, Sweden.
Publications dans "Dispositifs de fermeture vasculaire" :
With medical technology development, endovascular intervention has been widely used in clinical practice, and the establishment of surgical access through the femoral artery, where most vascular inter...
The aim of this prospective, multicentre, observational study was to compare the efficacy and safety of balloon-based and non-balloon-based vascular closure devices (VCDs)....
From March 2021 to May 2022, 2373 participants from 10 different centres were enrolled. Among them, 1672 patients with 5-7 Fr accesses were selected. Successful haemostasis, failure and safety were ev...
VCDs mechanism of action is statistically significant associated with the outcome. Non-balloon-based VCDs demonstrated a statistically significant better outcome: successful haemostasis was obtained i...
Our study suggests a better outcome with the same complication rate, except that for AVF incidence for non-balloon collagen plug device if compared to balloon occluders vascular closure devices....
VA-ECMO can be lifesaving in cardiogenic shock in children. While surgical vascular repair is the current standard of care for decannulation, it comes with notable risks. We present a series of eight ...
To evaluate the safety and effectiveness of sequential sutures and plugged vascular closure devices (VCDs) for large-bore access closure during percutaneous access endovascular aneurysm repair (PEVAR)...
Data on 16 patients who underwent PEVAR at the authors' center from January 2022 to May 2022 were retrospectively reviewed. The median age was 72 years (interquartile range [IQR], 59-75 years), with a...
Overall, 24 access sites were included. The median sheath size was 21 F (IQR, 18-23 F). The median hemostasis time was 11.0 minutes (IQR, 9.3-13.0 minutes), the median procedural time was 133.5 minute...
Placement of sequential suture and plug VCDs using 1 Proglide and dual Exoseal is a safe and effective method and may be an option for access closure during PEVAR....
There are conflicting data regarding the efficacy and safety of suture vs plug-based vascular closure devices (VCDs) for large-bore catheter management in patients undergoing transcatheter aortic valv...
We conducted a single-centre, all-comer, prospective registry study, enrolling patients undergoing TAVR for symptomatic severe aortic stenosis (AS) between the years 2009 and 2022. Clinical outcomes w...
Overall, 2368 patients were enrolled in the registry; 1315 (51.0% male, 81.0 ± 7.0 years) patients were included in the current analysis. P-VCD was used in 813 patients, whereas M-VCD was used in 502 ...
In patients undergoing TAVR for severe AS, M-VCD was associated with higher rates of VCs. This outcome was mainly driven by minor VCs. The rate of major VCs was low in both groups....
Vascular closure devices (VCDs) show fewer complications related to the puncture site than manual compression but can cause stenosis or occlusion of the common femoral artery (CFA). A patient in her 3...
To assess the safety of vascular closure devices in living-donor nephrectomy (LDN), as staplers and non-transfixion techniques (polymer locking and metal clips) are the methods employed to secure the ...
A systematic review and meta-analysis were conducted to assess the safety of vascular closure devices (International Prospective Register of Systematic Reviews [PROSPERO] registration: CRD42022364349)...
Of the 863 articles obtained, data were retrieved from 44 studies, which included 42 902 patients. In non-comparative studies, the pooled estimate rates for device failure, severe haemorrhage rate, co...
This study has confirmed that there is no evidence for the superiority of any vascular closure device in terms of safety in LDN. Standardised recommendations for vascular control in this context shoul...
To perform a systematic review and meta-analysis of the techniques and outcomes associated with percutaneous decannulation of venoarterial extracorporeal membrane oxygenation (VA-ECMO) using the Manta...
Peripheral VA-ECMO can be used to treat critically ill patients with conditions such as refractory cardiogenic shock. After percutaneous implantation of VA-ECMO, VA-ECMO can also be decannulated compl...
We performed a thorough literature search using various electronic databases. We included studies that reported outcomes after peripheral femorofemoral VA-ECMO decannulation with the Manta vascular cl...
We included seven studies with a total of 116 patients. The overall technical success of percutaneous decannulation of VA-ECMO with the Manta vascular closure device was 93.7%. The overall incidence o...
Percutaneous decannulation with the Manta vascular closure device is an effective and safe procedure that should be considered in suitable patients on VA-ECMO....
New vascular closure devices (VCD) are being introduced for achieving hemostasis after transcatheter aortic valve implantation (TAVI). However, no safety or efficacy data have been published compared ...
To compare the safety and efficacy of suture-based Perclose Prostyle as compared to plug-based MANTA device....
A total of 408 consecutive TAVI patients from two high volume TAVI centers were included in the present study. Patients were grouped according to VCD: Prostyle versus MANTA. Propensity score matching ...
After PSM, a total of 264 patients were analyzed, of them 132 in each group. Overall baseline characteristics of the two groups were comparable. Primary end-point was similar between MANTA as compared...
VCD for transfemoral TAVI using the new-generation Prostyle device or the MANTA device achieved comparable VARC-3 VC rates....
The objective of this study was to evaluate the annual costs and budget impact of using a vascular closure device to achieve hemostasis following femoral access endovascular procedures in England, com...
A budget impact model was developed in Microsoft® Excel, based on the estimated number of peripheral endovascular procedures eligible for day-case management performed annually by the National Health ...
The model estimated savings for the National Health Service of up to £4.5 million annually if vascular closure devices were used in every procedure instead of manual compression. The model estimated a...
The use of vascular closure devices for achieving hemostasis after peripheral endovascular procedures may be associated with lower resource use and cost burden, compared with manual compression, based...