Impact of reverse shoulder arthroplasty design and patient shoulder size on moment arms and muscle fiber lengths in shoulder abductors.


Journal

Journal of shoulder and elbow surgery
ISSN: 1532-6500
Titre abrégé: J Shoulder Elbow Surg
Pays: United States
ID NLM: 9206499

Informations de publication

Date de publication:
Dec 2023
Historique:
received: 03 03 2023
revised: 17 05 2023
accepted: 28 05 2023
medline: 14 11 2023
pubmed: 8 7 2023
entrez: 7 7 2023
Statut: ppublish

Résumé

Reverse shoulder arthroplasty (RSA) increases the moment arm of the deltoid; however, there is limited knowledge on the accompanying changes in muscle architecture that play a role in muscle force production. The purpose of this study was to use a geometric shoulder model to evaluate the anterior deltoid, middle deltoid, and supraspinatus regarding (1) the differences in moment arms and muscle-tendon lengths in small, medium, and large native shoulders and (2) the impact of 3 RSA designs on moment arms, muscle fiber lengths, and force-length (F-L) curves. A geometric model of the native glenohumeral joint was developed, validated, and adjusted to represent small, medium, and large shoulders. Moment arms, muscle-tendon lengths, and normalized muscle fiber lengths were assessed for the supraspinatus, anterior deltoid, and middle deltoid from 0° to 90° of abduction. RSA designs were modeled and virtually implanted, including a lateralized glenosphere with an inlay 135° humeral component (lateral glenoid-medial humerus [LGMH]), a medialized glenosphere with an onlay 145° humeral component (medial glenoid-lateral humerus [MGLH]), and a medialized glenosphere with an inlay 155° humeral component (medial glenoid-medial humerus [MGMH]). Descriptive statistics were used to compare moment arms and normalized muscle fiber lengths. As shoulder size increased, the moment arms and muscle-tendon lengths for the anterior deltoid, middle deltoid, and supraspinatus increased. All RSA designs achieved greater moment arms for the anterior and middle deltoid, with the MGLH design achieving the largest increase. The resting normalized muscle fiber length of the anterior and middle deltoid was substantially increased in the MGLH (1.29) and MGMH (1.24) designs, shifting the operating ranges of these muscles to the descending portions of their F-L curves, whereas the LGMH design maintained a resting deltoid fiber length (1.14) and operating range similar to the native shoulder. All RSA designs demonstrated a decrease in the native supraspinatus moment arm in early abduction, with the largest decrease in the MGLH design (-59%) and minimal decrease in the LGMH design (-14%). The supraspinatus operated on the ascending limb of its F-L curve in the native shoulder and remained on this portion of the F-L curve for all RSA designs. Although the MGLH design maximizes the abduction moment arm for the anterior and middle deltoid, overlengthening of the muscle may compromise deltoid muscle force production by forcing the muscle to operate on the descending portion of its F-L curve. In contrast, the LGMH design increases the abduction moment arm for the anterior and middle deltoid more modestly while allowing the muscle to operate near the plateau of its F-L curve and maximizing its force-producing potential.

Sections du résumé

BACKGROUND BACKGROUND
Reverse shoulder arthroplasty (RSA) increases the moment arm of the deltoid; however, there is limited knowledge on the accompanying changes in muscle architecture that play a role in muscle force production. The purpose of this study was to use a geometric shoulder model to evaluate the anterior deltoid, middle deltoid, and supraspinatus regarding (1) the differences in moment arms and muscle-tendon lengths in small, medium, and large native shoulders and (2) the impact of 3 RSA designs on moment arms, muscle fiber lengths, and force-length (F-L) curves.
METHODS METHODS
A geometric model of the native glenohumeral joint was developed, validated, and adjusted to represent small, medium, and large shoulders. Moment arms, muscle-tendon lengths, and normalized muscle fiber lengths were assessed for the supraspinatus, anterior deltoid, and middle deltoid from 0° to 90° of abduction. RSA designs were modeled and virtually implanted, including a lateralized glenosphere with an inlay 135° humeral component (lateral glenoid-medial humerus [LGMH]), a medialized glenosphere with an onlay 145° humeral component (medial glenoid-lateral humerus [MGLH]), and a medialized glenosphere with an inlay 155° humeral component (medial glenoid-medial humerus [MGMH]). Descriptive statistics were used to compare moment arms and normalized muscle fiber lengths.
RESULTS RESULTS
As shoulder size increased, the moment arms and muscle-tendon lengths for the anterior deltoid, middle deltoid, and supraspinatus increased. All RSA designs achieved greater moment arms for the anterior and middle deltoid, with the MGLH design achieving the largest increase. The resting normalized muscle fiber length of the anterior and middle deltoid was substantially increased in the MGLH (1.29) and MGMH (1.24) designs, shifting the operating ranges of these muscles to the descending portions of their F-L curves, whereas the LGMH design maintained a resting deltoid fiber length (1.14) and operating range similar to the native shoulder. All RSA designs demonstrated a decrease in the native supraspinatus moment arm in early abduction, with the largest decrease in the MGLH design (-59%) and minimal decrease in the LGMH design (-14%). The supraspinatus operated on the ascending limb of its F-L curve in the native shoulder and remained on this portion of the F-L curve for all RSA designs.
CONCLUSION CONCLUSIONS
Although the MGLH design maximizes the abduction moment arm for the anterior and middle deltoid, overlengthening of the muscle may compromise deltoid muscle force production by forcing the muscle to operate on the descending portion of its F-L curve. In contrast, the LGMH design increases the abduction moment arm for the anterior and middle deltoid more modestly while allowing the muscle to operate near the plateau of its F-L curve and maximizing its force-producing potential.

Identifiants

pubmed: 37419441
pii: S1058-2746(23)00495-0
doi: 10.1016/j.jse.2023.05.035
pii:
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

2550-2560

Informations de copyright

Copyright © 2023 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

Auteurs

Jay M Levin (JM)

Department of Orthopaedic Surgery, Duke University Medical Center, Durham, NC, USA. Electronic address: jay.m.levin@duke.edu.

Mattia Pugliese (M)

Department of Orthopaedic Surgery, Concordia Hospital, Rome, Italy.

Fabrizio Gobbi (F)

Department of Orthopaedic Surgery, Concordia Hospital, Rome, Italy.

Marcus G Pandy (MG)

Department of Mechanical Engineering, The University of Melbourne, Parkville, VIC, Australia.

Giovanni Di Giacomo (G)

Department of Orthopaedic Surgery, Concordia Hospital, Rome, Italy.

Mark A Frankle (MA)

Shoulder & Elbow Service, Florida Orthopaedic Institute, Tampa, FL, USA.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH