[Determination of prolactin reference intervals in different age groups].


Journal

Problemy endokrinologii
ISSN: 2308-1430
Titre abrégé: Probl Endokrinol (Mosk)
Pays: Russia (Federation)
ID NLM: 0140673

Informations de publication

Date de publication:
30 Jun 2023
Historique:
received: 06 04 2022
accepted: 18 01 2023
medline: 17 7 2023
pubmed: 14 7 2023
entrez: 14 7 2023
Statut: epublish

Résumé

Clinical diagnostic laboratories (CDL) have at their disposal various automated systems for the measurement of biochemical parameters and markers such as prolactin. Each of the test systems manufactures offers its own alternate design of the method, which makes standardization difficult. In endocrinological practice, the problem of result discrepancies often arises. In hormonal assays, the clinical picture of patients sometimes does not correspond to the reference values provided by the manufacturers, which determines the need to develop the method-specific reference values for a specific population. The difficulty in interpreting basal prolactin levels is not only due to a transient increase in the hormone levels caused by stress or excessive physical exertion, but also due to a significant variability of indicators in the same patient, even if all recommendations for blood sampling are followed. The aim of the study to determine the reference values in serum samples of women, men and children of different age groups for the VITROS Immunodiagnostic Systems and compare the results with the "expected prolactin levels" recommended by the method manufacturerMATERIALS AND METHODS: The monocentric study included 879 serum samples of apparently healthy subjects who were admitted to the Endocrinology Research Center. Measurements were performed using the VITROS ECi 3600 automatic chemiluminescence analyzer (Ortho-Clinical Diagnostics, Great Britain). For adult men and women reference values were 66-436 and 94-500 mIU/l respectively. When comparing the results of prolactin determination in women and men of the studied cohort with the "expected values" of the VITROS ECi 3600 manufacturer a systematic shift towards an increase in lower and upper limits of the reference values was found in both -cohorts. The obtained reference values of prolactin can be use in the determination of prolactin in the Russian population for VITROS ECi 3600 Immunodiagnostic Systems.

Sections du résumé

BACKGROUND BACKGROUND
Clinical diagnostic laboratories (CDL) have at their disposal various automated systems for the measurement of biochemical parameters and markers such as prolactin. Each of the test systems manufactures offers its own alternate design of the method, which makes standardization difficult. In endocrinological practice, the problem of result discrepancies often arises. In hormonal assays, the clinical picture of patients sometimes does not correspond to the reference values provided by the manufacturers, which determines the need to develop the method-specific reference values for a specific population. The difficulty in interpreting basal prolactin levels is not only due to a transient increase in the hormone levels caused by stress or excessive physical exertion, but also due to a significant variability of indicators in the same patient, even if all recommendations for blood sampling are followed.
AIM OBJECTIVE
The aim of the study to determine the reference values in serum samples of women, men and children of different age groups for the VITROS Immunodiagnostic Systems and compare the results with the "expected prolactin levels" recommended by the method manufacturerMATERIALS AND METHODS: The monocentric study included 879 serum samples of apparently healthy subjects who were admitted to the Endocrinology Research Center. Measurements were performed using the VITROS ECi 3600 automatic chemiluminescence analyzer (Ortho-Clinical Diagnostics, Great Britain).
RESULTS RESULTS
For adult men and women reference values were 66-436 and 94-500 mIU/l respectively. When comparing the results of prolactin determination in women and men of the studied cohort with the "expected values" of the VITROS ECi 3600 manufacturer a systematic shift towards an increase in lower and upper limits of the reference values was found in both -cohorts.
CONCLUSION CONCLUSIONS
The obtained reference values of prolactin can be use in the determination of prolactin in the Russian population for VITROS ECi 3600 Immunodiagnostic Systems.

Identifiants

pubmed: 37448243
doi: 10.14341/probl13095
pmc: PMC10350613
doi:

Substances chimiques

Prolactin 9002-62-4

Types de publication

English Abstract Journal Article

Langues

rus

Sous-ensembles de citation

IM

Pagination

16-23

Références

PLoS One. 2012;7(2):e31305
pubmed: 22363612
Clin Chem Lab Med. 2018 Apr 25;56(5):838-842
pubmed: 29194037
Clin Biochem Rev. 2018 Feb;39(1):3-16
pubmed: 30072818
Diabetologia. 2018 Dec;61(12):2549-2560
pubmed: 30306190
J Clin Endocrinol Metab. 2002 Dec;87(12):5410-5
pubmed: 12466327
Clin Chem Lab Med. 2020 Jul 28;58(8):1302-1313
pubmed: 32160154
BMC Endocr Disord. 2021 Oct 7;21(1):197
pubmed: 34620143
Ann Clin Biochem. 2015 Jan;52(Pt 1):61-6
pubmed: 25074991
Urology. 2018 Oct;120:114-119
pubmed: 30056193
Biochem Med (Zagreb). 2020 Jun 15;30(2):020710
pubmed: 32550818
Ann Lab Med. 2016 Jan;36(1):55-9
pubmed: 26522760

Auteurs

G S Kolesnikova (GS)

Endocrinology Research Center.

N M Malysheva (NM)

Endocrinology Research Center.

Z T Zuraeva (ZT)

Endocrinology Research Center.

L V Nikankina (LV)

Endocrinology Research Center.

G A Melnichenko (GA)

Endocrinology Research Center.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH