Résumé
Biventricular endocardial pacing (BiV-endo) and left bundle branch area pacing (LBBAP) are novel methods of delivering cardiac resynchronization therapy. These techniques are associated with improved activation times and acute hemodynamic response compared with conventional biventricular epicardial pacing (BiV-epi); however, the effects on repolarization and arrhythmic risk are unknown. The purpose of this study was to compare the effects of temporary BiV-epi, BiV-endo, and LBBAP on epicardial left ventricular (LV) repolarization using electrocardiographic imaging (ECGi). Eleven patients indicated for cardiac resynchronization therapy underwent a temporary pacing protocol with ECGi. BiV-endo was delivered via endocardial stimulation of the LV lateral wall. LBBAP was delivered by pacing the LV septum. Epicardial LV repolarization time (LVRT-95; time taken for 95% of the LV to repolarize), LV RT dispersion, mean LV activation recovery interval (ARI), LV ARI dispersion, and RT gradients were calculated. The protocol was completed in 10 patients. During LBBAP, there were significant reductions in LVRT-95 (94.9 ± 17.4 ms vs 125.0 ± 29.4 ms; P = .03) and LV RT dispersion (29.4 ± 6.3 ms vs 40.8 ± 11.4 ms; P = .015) compared with BiV-epi. In contrast, there were no significant differences between baseline, BiV-epi, or BiV-endo. There was a nonsignificant reduction in mean RT gradients between LBBAP and baseline rhythm (0.74 ± 0.22 ms/mm vs 1.01 ± 0.31 ms/mm; P = .07). There were no significant differences in mean LV ARI or LV ARI dispersion between groups. Temporary LBBAP reduces epicardial dispersion of repolarization compared with conventional BiV-epi. Further study is required to determine whether these repolarization changes on ECGi translate into a reduced risk of ventricular arrhythmia in clinical practice.
Sections du résumé
BACKGROUND
BACKGROUND
Biventricular endocardial pacing (BiV-endo) and left bundle branch area pacing (LBBAP) are novel methods of delivering cardiac resynchronization therapy. These techniques are associated with improved activation times and acute hemodynamic response compared with conventional biventricular epicardial pacing (BiV-epi); however, the effects on repolarization and arrhythmic risk are unknown.
OBJECTIVE
OBJECTIVE
The purpose of this study was to compare the effects of temporary BiV-epi, BiV-endo, and LBBAP on epicardial left ventricular (LV) repolarization using electrocardiographic imaging (ECGi).
METHODS
METHODS
Eleven patients indicated for cardiac resynchronization therapy underwent a temporary pacing protocol with ECGi. BiV-endo was delivered via endocardial stimulation of the LV lateral wall. LBBAP was delivered by pacing the LV septum. Epicardial LV repolarization time (LVRT-95; time taken for 95% of the LV to repolarize), LV RT dispersion, mean LV activation recovery interval (ARI), LV ARI dispersion, and RT gradients were calculated.
RESULTS
RESULTS
The protocol was completed in 10 patients. During LBBAP, there were significant reductions in LVRT-95 (94.9 ± 17.4 ms vs 125.0 ± 29.4 ms; P = .03) and LV RT dispersion (29.4 ± 6.3 ms vs 40.8 ± 11.4 ms; P = .015) compared with BiV-epi. In contrast, there were no significant differences between baseline, BiV-epi, or BiV-endo. There was a nonsignificant reduction in mean RT gradients between LBBAP and baseline rhythm (0.74 ± 0.22 ms/mm vs 1.01 ± 0.31 ms/mm; P = .07). There were no significant differences in mean LV ARI or LV ARI dispersion between groups.
CONCLUSION
CONCLUSIONS
Temporary LBBAP reduces epicardial dispersion of repolarization compared with conventional BiV-epi. Further study is required to determine whether these repolarization changes on ECGi translate into a reduced risk of ventricular arrhythmia in clinical practice.
Identifiants
pubmed: 37516414
pii: S1547-5271(23)02547-X
doi: 10.1016/j.hrthm.2023.07.065
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
1629-1636Informations de copyright
Copyright © 2023 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.