Development and validation of a mathematical model for evaluating shear-induced damage of von Willebrand factor.
Bleeding
CFD
Numerical model
Shear stress
Ventricular assist device (VAD)
Von Willebrand syndrome
Journal
Computers in biology and medicine
ISSN: 1879-0534
Titre abrégé: Comput Biol Med
Pays: United States
ID NLM: 1250250
Informations de publication
Date de publication:
09 2023
09 2023
Historique:
received:
27
04
2023
revised:
10
08
2023
accepted:
14
08
2023
medline:
11
9
2023
pubmed:
20
8
2023
entrez:
19
8
2023
Statut:
ppublish
Résumé
To develop a mathematical model for predicting shear-induced von Willebrand factor (vWF) function modification which can be used to guide ventricular assist devices (VADs) design, and evaluate the damage of high molecular weight multimers (HMWM)-vWF in VAD patients for reducing clinical complications. Mathematical models were constructed based on three morphological variations (globular vWF, unfolded vWF and degraded vWF) of vWF under shear stress conditions, in which parameters were obtained from previous studies or fitted by experimental data. Different clinical support modes (pediatric vs. adult mode), different VAD operating states (pulsation vs. constant mode) and different clinical VADs (HeartMate II, HeartWare and CentriMag) were utilized to analyze shear-induced damage of HMWM-vWF based on our vWF model. The accuracy and feasibility of the models were evaluated using various experimental and clinical cases, and the biomechanical mechanisms of HMWM-vWF degradation induced by VADs were further explained. The mathematical model developed in this study predicted VAD-induced HMWM-vWF degradation with high accuracy (correlation with experimental data r This study provides a validated mathematical model to assess the shear-induced degradation of HMWM-vWF, which can help to evaluate the damage of HMWM-vWF in patients implanted with VADs for reducing clinical complications, and to guide the optimization of VADs for improving hemocompatibility.
Identifiants
pubmed: 37597407
pii: S0010-4825(23)00844-2
doi: 10.1016/j.compbiomed.2023.107379
pii:
doi:
Substances chimiques
von Willebrand Factor
0
Types de publication
Journal Article
Research Support, Non-U.S. Gov't
Langues
eng
Sous-ensembles de citation
IM
Pagination
107379Informations de copyright
Copyright © 2023 Elsevier Ltd. All rights reserved.
Déclaration de conflit d'intérêts
Declaration of competing interest The authors declare that there are no conflicts of interest.