Rotational alignment of the lower extremity in the presence of total knee endoprosthesis: Reproducibility of torsion analyses using ultra-low-dose photon-counting CT.
Leg rotation
Photon-counting
Radiation dosage
Tomography, x-ray computed
Torsion measurement
Journal
European journal of radiology
ISSN: 1872-7727
Titre abrégé: Eur J Radiol
Pays: Ireland
ID NLM: 8106411
Informations de publication
Date de publication:
Oct 2023
Oct 2023
Historique:
received:
07
06
2023
revised:
25
07
2023
accepted:
18
08
2023
medline:
25
9
2023
pubmed:
27
8
2023
entrez:
26
8
2023
Statut:
ppublish
Résumé
Leg torsion analysis can provide valuable information in symptomatic patients after total knee arthroplasty. However, extensive beam-hardening and photon-starvation artifacts limit diagnostic assessability and dose reduction potential. For this study, we investigated the reproducibility of rotational measurements in ultra-low-dose photon-counting CT with spectral shaping via tin prefiltration. Employing a first-generation photon-counting CT, eight cadaveric specimens were examined with an established three-level scan protocol (hip: Sn 140, knee: Sn 100, ankle: Sn 100 kVp). In three body donors with unilateral knee endoprostheses, additional modified settings were applied (Sn 140 kVp at knee level). Protocols were executed with three dose levels (hip-knee-ankle, high-quality: 5.0-3.0-2.0 mGy, low-dose: 0.80-0.30-0.26 mGy, ultra-low-dose: 0.25-0.06-0.06 mGy). Six radiologists performed torsion analyses, additionally reporting their diagnostic confidence. Intraclass correlation coefficients (ICC) were calculated to assess interrater reliability. No significant differences were ascertained for femoral (p = 0.330), tibial (p = 0.177), and overall leg rotation measurements (p = 0.358) among high-quality, low-dose, and ultra-low-dose protocols. Interrater reliability was excellent for torsion of the femur (ICC 0.915, 95% confidence interval 0.871-0.947), tibia (0.960, 0.938-0.976), and overall leg (0.967, 0.945-0.981). In specimens with total knee endoprostheses, absolute rotational measurements were unaffected by dose level and tube voltage despite superior diagnostic confidence on the ipsilateral and contralateral sides with modified settings (p < 0.001). Combining the advantages of photon-counting CT and spectral shaping, reliable leg torsion analyses are feasible with ultra-low radiation exposure even in the presence of total knee endoprostheses.
Identifiants
pubmed: 37632998
pii: S0720-048X(23)00369-8
doi: 10.1016/j.ejrad.2023.111055
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
111055Informations de copyright
Copyright © 2023 Elsevier B.V. All rights reserved.
Déclaration de conflit d'intérêts
Declaration of Competing Interest The authors declare the following financial interests/personal relationships which may be considered as potential competing interests: Jan-Peter Grunz, Thorsten Alexander Bley and Andreas Steven Kunz have received speaker honoraria from Siemens Healthineers within the last three years. The other authors of this manuscript declare no further relationships with any companies, whose products or services may be related to the subject matter of the article. The Department of Diagnostic and Interventional Radiology receives ongoing research funding from Siemens Healthineers.