The accuracy of dynamic computer assisted implant surgery in fully edentulous jaws: A retrospective case series.


Journal

Clinical oral implants research
ISSN: 1600-0501
Titre abrégé: Clin Oral Implants Res
Pays: Denmark
ID NLM: 9105713

Informations de publication

Date de publication:
Nov 2023
Historique:
revised: 28 07 2023
received: 16 03 2023
accepted: 13 08 2023
medline: 10 11 2023
pubmed: 29 8 2023
entrez: 29 8 2023
Statut: ppublish

Résumé

To evaluate the accuracy of implant placement using a dynamic navigation system in fully edentulous jaws and to analyze the influence of implant distribution on implant position accuracy. Edentulous patients who received implant placement using a dynamic navigation system were included. Four to six mini screws were placed in the edentulous jaw under local anesthesia as fiducial markers. Then patients received CBCT scans. Virtual implant positions were designed in the planning software based on CBCT data. Under local anesthesia, implants were inserted under the guidance of the dynamic navigation system. CBCTs were taken following implant placement. The deviation between the actual and planned implant positions was measured by comparing the pre- and postsurgery CBCT. A total of 13 edentulous patients with 13 edentulous maxillae and 7 edentulous mandibles were included, and 108 implants were placed. The average linear deviations at the implant entry point and apex were 1.08 ± 0.52 mm and 1.15 ± 0.60 mm, respectively. The average angular deviation was 2.85 ± 1.20°. No significant difference was detected in linear and angular deviations between the maxillary and mandibular implants, neither between the anterior and posterior implants. The dynamic navigation system provides high accuracy for implant placement in fully edentulous jaws, while the distribution of the implants showed little impact on implant position accuracy.

Identifiants

pubmed: 37642206
doi: 10.1111/clr.14168
doi:

Substances chimiques

Dental Implants 0

Types de publication

Journal Article

Langues

eng

Pagination

1278-1288

Subventions

Organisme : National Key Research and Development Program of China
ID : No.2020YFC2009000, Project No: 2020YFC2009005
Organisme : Program for New Clinical Techniques Therapies of Peking University School and Hospital of Stomatology
ID : PKUSSNCT-22B03
Organisme : Beijing Natural Science Foundation
ID : No.7222228
Organisme : National Program for Multidisciplinary Cooperative Treatment on Major Diseases
ID : PKUSSNMP-202004

Informations de copyright

© 2023 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Références

Block, M. S., Emery, R. W., Lank, K., & Ryan, J. (2017). Implant placement accuracy using dynamic navigation. The International Journal of Oral & Maxillofacial Implants, 32, 92-99. https://doi.org/10.11607/jomi.5004
D'Haese, J., Ackhurst, J., Wismeijer, D., De Bruyn, H., & Tahmaseb, A. (2017). Current state of the art of computer-guided implant surgery. Periodontology, 2000(73), 121-133. https://doi.org/10.1111/prd.12175
Feng, Y., Yao, Y., & Yang, X. (2022). Effect of a dynamic navigation device on the accuracy of implant placement in the completely edentulous mandible: An in vitro study. The Journal of Prosthetic Dentistry. online ahead of print. https://doi.org/10.1016/j.prosdent.2021.12.012
Jaemsuwan, S., Arunjaroensuk, S., Kaboosaya, B., Subbalekha, K., Mattheos, N., & Pimkhaokham, A. (2023). Comparison of the accuracy of implant position among freehand implant placement, static and dynamic computer-assisted implant surgery in fully edentulous patients: A non-randomized prospective study. International Journal of Oral and Maxillofacial Surgery, 52, 264-271. https://doi.org/10.1016/j.ijom.2022.05.009
Jorba-García, A., González-Barnadas, A., Camps-Font, O., Figueiredo, R., & Valmaseda-Castellón, E. (2021). Accuracy assessment of dynamic computer-aided implant placement: A systematic review and meta-analysis. Clinical Oral Investigations, 25, 2479-2494. https://doi.org/10.1007/s00784-021-03833-8
Jung, R. E., Schneider, D., Ganeles, J., Wismeijer, D., Zwahlen, M., Hämmerle, C. H., & Tahmaseb, A. (2009). Computer technology applications in surgical implant dentistry: A systematic review. The International Journal of Oral & Maxillofacial Implants, 24(Suppl), 92-109.
Kaewsiri, D., Panmekiate, S., Subbalekha, K., Mattheos, N., & Pimkhaokham, A. (2019). The accuracy of static vs. dynamic computer-assisted implant surgery in single tooth space: A randomized controlled trial. Clinical Oral Implants Research, 30, 505-514. https://doi.org/10.1111/clr.13435
Kunakornsawat, W., Serichetaphongse, P., Arunjaroensuk, S., Kaboosaya, B., Mattheos, N., & Pimkhaokham, A. (2023). Training of novice surgeons using dynamic computer assisted dental implant surgery: An exploratory randomized trial. Clinical Implant Dentistry and Related Research, 25, 511-518. https://doi.org/10.1111/cid.13201
Meng, T., & Zhang, X. (2022). Accuracy of intentionally tilted implant placement in the maxilla using dynamic navigation: A retrospective clinical analysis. International Journal of Oral and Maxillofacial Surgery, 51, 552-557. https://doi.org/10.1016/j.ijom.2021.09.004
Moon, S. Y., Lee, K. R., Kim, S. G., & Son, M. K. (2016). Clinical problems of computer-guided implant surgery. Maxillofac Plast Reconstr Surg, 38, 15. https://doi.org/10.1186/s40902-016-0063-3
Pan, S., Awad, M., Thomason, J. M., Dufresne, E., Kobayashi, T., Kimoto, S., Wollin, S. D., & Feine, J. S. (2008). Sex differences in denture satisfaction. Journal of Dentistry, 36, 301-308. https://doi.org/10.1016/j.jdent.2008.02.009
Pan, S., Dagenais, M., Thomason, J. M., Awad, M., Emami, E., Kimoto, S., Wollin, S. D., & Feine, J. S. (2010). Does mandibular edentulous bone height affect prosthetic treatment success? Journal of Dentistry, 38, 899-907. https://doi.org/10.1016/j.jdent.2010.08.002
Pellegrino, G., Bellini, P., Cavallini, P. F., Ferri, A., Zacchino, A., Taraschi, V., Marchetti, C., & Consolo, U. (2020). Dynamic navigation in dental implantology: The influence of surgical experience on implant placement accuracy and operating time. An in vitro study. International Journal of Environmental Research and Public Health, 17. https://doi.org/10.3390/ijerph17062153
Pimkhaokham, A., Jiaranuchart, S., Kaboosaya, B., Arunjaroensuk, S., Subbalekha, K., & Mattheos, N. (2022). Can computer-assisted implant surgery improve clinical outcomes and reduce the frequency and intensity of complications in implant dentistry? A critical review. Periodontol, 2000(90), 197-223. https://doi.org/10.1111/prd.12458
Pomares-Puig, C., Sánchez-Garcés, M. A., & Jorba-García, A. (2021). Dynamic and static computer-guided surgery using the double-factor technique for completely edentulous patients: A dental technique. The Journal of Prosthetic Dentistry, 128, 852-857. https://doi.org/10.1016/j.prosdent.2021.02.022
Schneider, D., Marquardt, P., Zwahlen, M., & Jung, R. E. (2009). A systematic review on the accuracy and the clinical outcome of computer-guided template-based implant dentistry. Clinical Oral Implants Research, 20(Suppl 4), 73-86. https://doi.org/10.1111/j.1600-0501.2009.01788.x
Schnutenhaus, S., Edelmann, C., Knipper, A., & Luthardt, R. G. (2021). Accuracy of dynamic computer-assisted implant placement: A systematic review and meta-analysis of clinical and In vitro studies. Journal of Clinical Medicine, 10. https://doi.org/10.3390/jcm10040704
Seo, C., & Juodzbalys, G. (2018). Accuracy of guided surgery via stereolithographic mucosa-supported surgical guide in implant surgery for edentulous patient: A systematic review. J Oral Maxillofac Res, 9, e1. https://doi.org/10.5037/jomr.2018.9101
Smitkarn, P., Subbalekha, K., Mattheos, N., & Pimkhaokham, A. (2019). The accuracy of single-tooth implants placed using fully digital-guided surgery and freehand implant surgery. Journal of Clinical Periodontology, 46, 949-957. https://doi.org/10.1111/jcpe.13160
Tahmaseb, A., Wu, V., Wismeijer, D., Coucke, W., & Evans, C. (2018). The accuracy of static computer-aided implant surgery: A systematic review and meta-analysis. Clinical Oral Implants Research, 29(Suppl 16), 416-435. https://doi.org/10.1111/clr.13346
Tao, B., Feng, Y., Fan, X., Zhuang, M., Chen, X., Wang, F., & Wu, Y. (2022). Accuracy of dental implant surgery using dynamic navigation and robotic systems: An in vitro study. Journal of Dentistry, 123, 104170. https://doi.org/10.1016/j.jdent.2022.104170
Tao, B., Shen, Y., Sun, Y., Huang, W., Wang, F., & Wu, Y. (2020). Comparative accuracy of cone-beam CT and conventional multislice computed tomography for real-time navigation in zygomatic implant surgery. Clinical Implant Dentistry and Related Research, 22, 747-755. https://doi.org/10.1111/cid.12958
Tao, B. X., Wang, F., Shen, Y. H., Fan, S. Q., Huang, W., Wang, Y. P., & Wu, Y. Q. (2020). Accuracy and clinical outcome of a real-time surgical navigation system for the placement of quad zygomatic implants. Zhonghua Kou Qiang Yi Xue Za Zhi, 55, 845-850. https://doi.org/10.3760/cma.j.cn112144-20200614-00343
Wei, S. M., Zhu, Y., Wei, J. X., Zhang, C. N., Shi, J. Y., & Lai, H. C. (2021). Accuracy of dynamic navigation in implant surgery: A systematic review and meta-analysis. Clinical Oral Implants Research, 32, 383-393. https://doi.org/10.1111/clr.13719
Widmann, G., Stoffner, R., & Bale, R. (2009). Errors and error management in image-guided craniomaxillofacial surgery. Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontics, 107, 701-715. https://doi.org/10.1016/j.tripleo.2009.02.011
Widmann, G., Stoffner, R., Keiler, M., Zangerl, A., Widmann, R., Puelacher, W., & Bale, R. (2009). A laboratory training and evaluation technique for computer-aided oral implant surgery. Int J Med Robot, 5, 276-283. https://doi.org/10.1002/rcs.258
Wu, Y., Tao, B., Lan, K., Shen, Y., Huang, W., & Wang, F. (2022). Reliability and accuracy of dynamic navigation for zygomatic implant placement. Clinical Oral Implants Research, 33, 362-376. https://doi.org/10.1111/clr.13897
Yimarj, P., Subbalekha, K., Dhanesuan, K., Siriwatana, K., Mattheos, N., & Pimkhaokham, A. (2020). Comparison of the accuracy of implant position for two-implants supported fixed dental prosthesis using static and dynamic computer-assisted implant surgery: A randomized controlled clinical trial. Clinical Implant Dentistry and Related Research, 22, 672-678. https://doi.org/10.1111/cid.12949
Yotpibulwong, T., Arunjaroensuk, S., Kaboosaya, B., Sinpitaksakul, P., Arksornnukit, M., Mattheos, N., & Pimkhaokham, A. (2023). Accuracy of implant placement with a combined use of static and dynamic computer-assisted implant surgery in single tooth space: A randomized controlled trial. Clinical Oral Implants Research, 34, 330-341. https://doi.org/10.1111/clr.14043
Zitzmann, N. U., & Marinello, C. P. (2000). Fixed or removable implant-supported restorations in the edentulous maxilla: Literature review. Practical Periodontics and Aesthetic Dentistry, 12, 599-608; quiz 609.

Auteurs

Jiayi Wang (J)

Department of Orthodontics, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices & Beijing Key Laboratory of Digital Stomatology & Research Center of Engineering and Technology for Computerized Dentistry Ministry of Health & NMPA Key Laboratory for Dental Materials, Beijing, People's Republic of China.

Yanjun Ge (Y)

Department of Prosthodontics, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices & Beijing Key Laboratory of Digital Stomatology & Research Center of Engineering and Technology for Computerized Dentistry Ministry of Health & NMPA Key Laboratory for Dental Materials, Beijing, People's Republic of China.

Sven Mühlemann (S)

Clinic of Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland.

Shaoxia Pan (S)

Department of Prosthodontics, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices & Beijing Key Laboratory of Digital Stomatology & Research Center of Engineering and Technology for Computerized Dentistry Ministry of Health & NMPA Key Laboratory for Dental Materials, Beijing, People's Republic of China.

Ronald E Jung (RE)

Clinic of Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH