The effect of the simulated aging by thermocycling on the elastic modulus of ethylene-vinyl acetate brands and stress/strain development during an impact: An in vitro and 3D-FEA analysis.


Journal

Dental traumatology : official publication of International Association for Dental Traumatology
ISSN: 1600-9657
Titre abrégé: Dent Traumatol
Pays: Denmark
ID NLM: 101091305

Informations de publication

Date de publication:
Apr 2024
Historique:
revised: 26 09 2023
received: 07 07 2023
accepted: 28 09 2023
medline: 18 3 2024
pubmed: 11 10 2023
entrez: 11 10 2023
Statut: ppublish

Résumé

Mouthguards are used to prevent dental trauma and orofacial injuries. The aim of this study was to evaluate the influence of ethylene-vinyl acetate (EVA) aging by thermocycling on elastic modulus, stress, strain and shock absorption ability of different ethylene-vinyl acetate brands used for mouthguards. Thirty EVA samples with a dimension of 70 × 10 × 3 mm were obtained from four commercial brands (Bioart®, Erkodent®, Polyshok® and Proform®). Fifteen samples were submitted to 10,000 cycles (5°C-55°C) in a thermocycling machine with an immersion time of 30 s and a transfer time of 5 s. The samples were submitted to a uniaxial tensile test in a universal testing machine to calculate the elastic modulus. Data were statistically evaluated by two-way ANOVA and Holm-Sidak test. A three-dimensional model of the anterior maxilla was created using Rhinoceros 5.0. A 3 mm custom-fitted mouthguard was simulated. The three-dimensional volumetric mesh was generated using the Patran software (MSC Software) with isoparametrics, 4-noded tetrahedral elements and exported to Marc/Mentat (MSC Software) as element number 134. A non-linear dynamic impact analysis was performed in which a rigid object struck the central incisor at a speed of 5 m/s. The stresses were evaluated by the modified von Mises criteria and the strains were also recorded. Statistically significant differences were observed for elastic modulus values (p < .001). Mean and standard deviation values (MPa) without thermocycling were: Bioart (34.5 ± 0.9), Erkodent (15.0 ± 0.4), Polyshok (17.3 ± 0.4), Proform: (20.6 ± 0.8); and with thermocycling: Bioart (25.4 ± 0.8), Erkodent (10.7 ± 0.5), Polyshok (13.3 ± 0.6), Proform (13.1 ± 0.6). The thermocycling process reduced stress and strain levels regardless of the mouthguard materials. Shock absorption ability calculated based on the strain values was increased with thermocycling process. The thermocycling process, regardless of the commercial brand, reduced the stress/strain and increased the shock absorption ability of mouthguards.

Sections du résumé

BACKGROUND/AIM OBJECTIVE
Mouthguards are used to prevent dental trauma and orofacial injuries. The aim of this study was to evaluate the influence of ethylene-vinyl acetate (EVA) aging by thermocycling on elastic modulus, stress, strain and shock absorption ability of different ethylene-vinyl acetate brands used for mouthguards.
METHODS METHODS
Thirty EVA samples with a dimension of 70 × 10 × 3 mm were obtained from four commercial brands (Bioart®, Erkodent®, Polyshok® and Proform®). Fifteen samples were submitted to 10,000 cycles (5°C-55°C) in a thermocycling machine with an immersion time of 30 s and a transfer time of 5 s. The samples were submitted to a uniaxial tensile test in a universal testing machine to calculate the elastic modulus. Data were statistically evaluated by two-way ANOVA and Holm-Sidak test. A three-dimensional model of the anterior maxilla was created using Rhinoceros 5.0. A 3 mm custom-fitted mouthguard was simulated. The three-dimensional volumetric mesh was generated using the Patran software (MSC Software) with isoparametrics, 4-noded tetrahedral elements and exported to Marc/Mentat (MSC Software) as element number 134. A non-linear dynamic impact analysis was performed in which a rigid object struck the central incisor at a speed of 5 m/s. The stresses were evaluated by the modified von Mises criteria and the strains were also recorded.
RESULTS RESULTS
Statistically significant differences were observed for elastic modulus values (p < .001). Mean and standard deviation values (MPa) without thermocycling were: Bioart (34.5 ± 0.9), Erkodent (15.0 ± 0.4), Polyshok (17.3 ± 0.4), Proform: (20.6 ± 0.8); and with thermocycling: Bioart (25.4 ± 0.8), Erkodent (10.7 ± 0.5), Polyshok (13.3 ± 0.6), Proform (13.1 ± 0.6). The thermocycling process reduced stress and strain levels regardless of the mouthguard materials. Shock absorption ability calculated based on the strain values was increased with thermocycling process.
CONCLUSION CONCLUSIONS
The thermocycling process, regardless of the commercial brand, reduced the stress/strain and increased the shock absorption ability of mouthguards.

Identifiants

pubmed: 37818928
doi: 10.1111/edt.12896
doi:

Substances chimiques

polyethylene-polyvinylacetate copolymer 0
vinyl acetate L9MK238N77
Ethylenes 0
Polyethylenes 0
Polyvinyls 0
Vinyl Compounds 0

Types de publication

Journal Article

Langues

eng

Pagination

204-212

Subventions

Organisme : Conselho Nacional de Desenvolvimento Científico e Tecnológico

Informations de copyright

© 2023 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Références

Fronza HP, Stolf SC, Taguchi CMC, Coto NP, Padilha ACL. Determinants for traumatic orofacial injuries in sport: extrinsic factors in a scoping review. Dent Traumatol. 2020;36:598-606.
Ozawa T, Takeda T, Ishigami K, Narimatsu K, Hasegawa K, Nakajima K, et al. Shock absorption ability of mouthguard against forceful, traumatic mandibular closure. Dent Traumatol. 2014;30:204-210.
Fernandes LM, Neto JC, Lima TF, Magno MB, Santiago BM, Cavalcanti YW, et al. The use of mouthguards and prevalence of dentoalveolar trauma among athletes: a systematic review and meta-analysis. Dent Traumatol. 2019;35:54-72.
Verissimo C, Costa PV, Santos-Filho PCF, Fernandes-Neto AJ, Tantbirojn D, Versluis A, et al. Evaluation of a dentoalveolar model for testing mouthguards: stress and strain analyses. Dent Traumatol. 2016;32:4-13.
Roberts HW. Sports mouthguard overview: materials, fabrication techniques, existing standards, and future research needs. Dent Traumatol. 2023;39(2):101-108.
Tribst JPM, de Oliveira Dal Piva AM, Borges ALS, Bottino MA. Influence of custom-made and stock mouthguard thickness on biomechanical response to a simulated impact. Dent Traumatol. 2018;34(6):429-437.
Tribst JPM, Dal Piva AMO, Bottino MA, Kleverlaan CJ, Koolstra JH. Mouthguard use and TMJ injury prevention with different occlusions: a three-dimensional finite element analysis. Dent Traumatol. 2020;36(6):662-669.
Verissimo C, Costa PV, Santos-Filho PC, Tantbirojn D, Versluis A, Soares CJ. Custom-fitted EVA mouthguards: what is the ideal thickness? A dynamic finite element impact study. Dent Traumatol. 2016;32:95-102.
Park JB, Shaull KL, Overton B, Donly KJ. Improving mouth guards. J Prosthet Dent. 1994;72:373-380.
Gould TE, Piland SG, Shin J, Hoyle CE, Nazarenko S. Characterization of mouthguard materials: physical and mechanical properties of commercialized products. Dent Mater. 2009;25:771-780.
Low D, Sumii T, Swain MV, Ishigami K, Takeda T. Instrumented indentation characterization of mouth-guard materials. Dent Mater. 2002;18:211-215.
Coto NP, Brito e Dias R, Costa RA, Antoniazzi TF, de Carvalho EP. Mechanical behavior of ethylene vinyl acetate copolymer (EVA) used for fabrication of mouthguards and interocclusal splints. Braz Dent J. 2007;18:324-328.
Chabrier F, Lloyd CH, Scrimgeour SN. Measurement at low strain rates of the elastic properties of dental polymeric materials. Dent Mater. 1999;15:33-38.
American Society for Testing and Materials. ASTM F697-80 standard practice for care and use of mouthguards. Annual book of ASTM standards. West Conshohocken: ASTM; 1986. p. 323.
Gale MS, Darvell BW. Thermal cycling procedures for laboratory testing of dental restorations. J Dent. 1999;27:89-99.
Firmiano TC, Oliveira AAD, Costa PVDM, Cardoso LS, Pereira RD, Veríssimo C. Influence of different ethylene-vinyl acetate brands used for custom-fitted mouthguard fabrication on the stress and strain during an impact. Dental Traumatol. 2022;00:1-8.
Versluis A, Versluis-Tantbirojn D. Filling cavities or restoring teeth? J Tenn Dent Assoc. 2011;91:36-42.
Kuwahara R, Tomita R, Ogawa N, Nakajima K, Takeda T, Uehara H, et al. Crystallization and hardening of poly(ethylene-co-vinyl acetate) mouthguards during routine use. Sci Rep. 2017;7:44672.
Carvalho VF, Soares PB, Verissimo C, Pessoa RS, Versluis A, Soares CJ. Mouthguard biomechanics for protecting dental implants from impact: experimental and finite element impact analysis. Int J Oral Maxillofac Implants. 2018;33:335-343.
Alves JCC, Borges GA, Versluis A, Soares CJ, Veríssimo C. Effect of orthodontic bracket type and mouthguard presence on the stress and strain during a frontal impact. Braz Dent J. 2020;31:540-547.
de Bragança GF, de Souza IF, Soares PBF, Soares CJ. Biomechanical effects of a hard insert and air space in mouthguards on the shock absorption and protection against fractures of direct resin composite veneers from trauma. Dental Traumatol. 2023;00:1-10.
Dal Piva AMO, Tribst JPM, Borges ALS, Kleverlaan CJ, Feilzer AJ. The ability of mouthguards to protect veneered teeth: a 3D finite element analysis. Dent Traumatol. 2023;39(3):191-199.
Parker K, Marlow B, Patel N, Gill DS. A review of mouthguards: effectiveness, types, characteristics and indications for use. Br Dent J. 2017;222:629-633.
Benli M, Eker Gümüş B, Kahraman Y, Gökçen-Rohlig B, Evlioğlu G, Huck O, et al. Surface roughness and wear behavior of occlusal splint materials made of contemporary and high-performance polymers. Odontology. 2020;108:240-250.
Kim AJ, Shin SJ, Yu SH, Oh S, Bae JM. Shear bond strengths of various resin cements between three types of adherends and bovine teeth with and without thermocycling. Dent Mater J. 2022;41:323-332.
Waked EJ, Lee TK, Caputo AA. Effects of aging on the dimensional stability of custom-made mouthguards. Quintessence Int. 2002;33:700-705.
Rossi GD, Lisman P, Leyte-Vidal MA. A preliminary report of structural changes to mouthguards during 1 season of high school football. J Athl Train. 2007;42:47-50.
Sliwkanich L, Ouanounou A. Mouthguards in dentistry: Current recommendations for dentists. Dental Traumatol. 2021;00:1-11.
Zarone F, Sorrentino R, Apicella D, Valentino B, Ferrari M, Aversa R, et al. Evaluation of the biomechanical behavior of maxillary central incisors restored by means of endocrowns compared to a nat- ural tooth: a 3D static linear finite elements analysis. Dent Mater. 2006;22:1035-1044.
Sano H, Ciucchi B, Matthews WG, Pashley DH. Tensile properties of mineralized and demineralized human and bovine dentin. J Dent Res. 1994;73:1205-1211.
Rees JS, Jacobsen PH. Elastic modulus of the periodontal ligament. Biomaterials. 1997;18:995-999.
Carter DR, Hayes WC. Compact bone fatigue damage-I. Residual strength and stiffness. J Biomech. 1977;10:325-337.
American Society for Testing and Materials. ASTM A276 specification for stainless steel bars and shapes. Annual book of ASTM standards. West Conshohocken: ASTM; 2013. p. 33.

Auteurs

Paulo Victor de Moura Costa (PVM)

Department of Oral Rehabilitation, Federal University of Goiás, Goiânia, Brazil.

Tainah Costa Firmiano (TC)

Department of Oral Rehabilitation, Federal University of Goiás, Goiânia, Brazil.

Gilberto Antônio Borges (GA)

Department of Dental Materials and Restorative Dentistry, University of Uberaba, Uberaba, Brazil.

Rodrigo Pereira Dantas (RP)

School of Dentistry, Faculdades de Ciências Odontológicas, FCO, Montes Claros, Brazil.

Crisnicaw Veríssimo (C)

Department of Oral Rehabilitation, Federal University of Goiás, Goiânia, Brazil.

Articles similaires

Silicon Dioxide Water Hot Temperature Compressive Strength X-Ray Diffraction
Humans Surgical Staplers Surgical Stapling Postoperative Complications Treatment Outcome

Characterization of 3D printed composite for final dental restorations.

Lucas Eigi Borges Tanaka, Camila da Silva Rodrigues, Manassés Tércio Vieira Grangeiro et al.
1.00
Composite Resins Materials Testing Printing, Three-Dimensional Surface Properties Flexural Strength
Animals Robotics Algorithms Sperm Whale Vocalization, Animal

Classifications MeSH