Mitral valve-in-valve with 4D intracardiac echocardiography: Procedural and imaging technique.
ECHO-intracardiac echo
MV-mitral valve disease
VALV-valvular heart disease
percutaneous intervention (PI)
Journal
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions
ISSN: 1522-726X
Titre abrégé: Catheter Cardiovasc Interv
Pays: United States
ID NLM: 100884139
Informations de publication
Date de publication:
01 2024
01 2024
Historique:
revised:
09
10
2023
received:
28
06
2023
accepted:
17
10
2023
medline:
4
1
2024
pubmed:
27
10
2023
entrez:
27
10
2023
Statut:
ppublish
Résumé
Transcatheter mitral valve-in-valve (ViV) has emerged as a safe and effective therapeutic option for patients with a degenerated mitral bioprosthesis. As procedural techniques mature and operator experience improve, there is a push to adopt a "minimalist" approach of using conscious sedation instead of general anesthesia for faster recovery. The heavy reliance on fluoroscopy for ViV deployment makes feasible the use of intracardiac echocardiography (ICE) instead of transesophageal echocardiography for other procedural imaging requirements. We hereby use a case example to illustrate a step-by-step approach of using four-dimensional ICE to guide transcatheter mitral ViV under conscious sedation.
Types de publication
Case Reports
Langues
eng
Sous-ensembles de citation
IM
Pagination
234-237Informations de copyright
© 2023 The Authors. Catheterization and Cardiovascular Interventions published by Wiley Periodicals LLC.
Références
Guerrero M, Pursnani A, Narang A, et al. Prospective evaluation of transseptal TMVR for failed surgical bioprostheses. JACC Cardiovas Interven. 2021;14(8):859-872. doi:10.1016/j.jcin.2021.02.027
Eleid MF, Wang DD, Pursnani A, et al. 2-Year outcomes of transcatheter mitral valve replacement in patients with annular calcification, rings, and bioprostheses. JACC. 2022;80(23):2171-2183. doi:10.1016/j.jacc.2022.09.037
Sanchez CE, Yakubov SJ, Singh G, Rogers JH, Kander NH, Tang GHL. 4-Dimensional intracardiac echocardiography in transcatheter mitral valve repair with the mitraclip system. JACC Cardiovas Imag. 2021;14(10):2033-2040. doi:10.1016/j.jcmg.2020.08.042
Tang GHL, Yakubov SJ, Sanchez Soto CE. 4-Dimensional intracardiac echocardiography in transcatheter tricuspid valve repair with the MitraClip system. JACC Cardiovas Imag. 2020;13(7):1591-1600. doi:10.1016/j.jcmg.2019.10.024
Davidson CJ, Abramson S, Smith RL, et al. Transcatheter tricuspid repair with the use of 4-dimensional intracardiac echocardiography. JACC Cardiovas Imag. 2022;15(3):533-538. doi:10.1016/j.jcmg.2021.01.029
Freitas-Ferraz AB, Bernier M, Vaillancourt R, et al. Safety of transesophageal echocardiography to guide structural cardiac interventions. JACC. 2020;75(25):3164-3173. doi:10.1016/j.jacc.2020.04.069
Butala NM, Chung M, Secemsky EA, et al. Conscious sedation versus general anesthesia for transcatheter aortic valve replacement. JACC Cardiovas Interven. 2020;13(11):1277-1287. doi:10.1016/j.jcin.2020.03.008