Comprehensive UHPLC-MS screening methods for the analysis of triazolopyrazine precursor and its genotoxic nitroso-derivative in sitagliptin pharmaceutical formulation.
NTTP
Nitrites
Nitrosation
Scavengers
Sitagliptin
Triazolopyrazine
Journal
Journal of pharmaceutical and biomedical analysis
ISSN: 1873-264X
Titre abrégé: J Pharm Biomed Anal
Pays: England
ID NLM: 8309336
Informations de publication
Date de publication:
20 Jan 2024
20 Jan 2024
Historique:
received:
21
07
2023
revised:
27
09
2023
accepted:
07
11
2023
medline:
6
12
2023
pubmed:
18
11
2023
entrez:
17
11
2023
Statut:
ppublish
Résumé
A case study on Sitagliptin drug products and Sitagliptin/Metformin drug products concerning contamination with N-nitrosamines was performed using two newly developed analytical methods for determination of N-nitroso-triazolopyrazine (NTTP; 7-nitroso-3-(trifluoromethyl)-5,6,7,8-tetrahydro-[1,2,4]triazolo[4,3-a]pyrazine) and its precursor triazolopyrazine (3-(trifluoromethyl)-5,6,7,8-tetrahydro-[1,2,4]triazolo[4,3-a]pyrazine). The method for determination of triazolopyrazine was previously unpublished, the method for determination of NTTP was published only for analysis of active pharmaceutical ingredient Sitagliptin and not the drug forms. Solving the N-nitrosamine contamination is requested by regulatory authorities all over the world and thus is vital for all pharmaceutical companies. The solution always requires a sensitive analytical method. Both newly developed methods use liquid chromatography coupled with mass spectrometry (single quadrupole analyzer in case of triazolopyrazine and triple quadrupole analyzer in case of NTTP). Separation of triazolopyrazine was achieved on a column Acquity CSH C18 using a mobile phase consisting of aqueous ammonium formate buffered at pH 4.2 and acetonitrile. Detection was performed using positive electrospray and selected ion monitoring at m/z 193. Separation of NTTP was achieved on a column Acquity HSS T3 using a mobile phase consisting of 0.1 % formic acid in water and methanol. Detection was performed using positive electrospray and multiple reaction monitoring at transitions m/z 222.15→42.05 (collision energy 17 eV) and m/z 222.15→192.15 (collision energy 11 eV). Two issues specific to NTTP and triazolopyrazine previously not described in scientific literature were successfully troubleshooted. Spontaneous degradation of Sitagliptin to triazolopyrazine and methyl (R)-3-amino-4-(2,4,5-trifluorophenyl)butanoate was solved by using N,N-dimethylformamide as sample solvent during development of the method for quantitation of triazolopyrazine. A bad peak shape of NTTP due to the presence of rotamers of NTTP was successfully troubleshooted by increasing column temperature. Both methods were used during an optimization study of manufacturing of Sitagliptin and Sitagliptin/Metformin drug products. The goal of the study was to decrease NTTP content in the final drug product under the strict legislative limit set by Federal Drug Agency. The efficacy of several solutions was proven, but could not be fully disclosed due to Intellectual Property Protection policy of Zentiva. Instead, a brief review of recently published strategies to cope with N-nitrosamine contamination is presented.
Identifiants
pubmed: 37976984
pii: S0731-7085(23)00630-1
doi: 10.1016/j.jpba.2023.115861
pii:
doi:
Substances chimiques
Sitagliptin Phosphate
TS63EW8X6F
Metformin
9100L32L2N
Pyrazines
0
Nitrosamines
0
Pharmaceutical Preparations
0
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
115861Informations de copyright
Copyright © 2023 Elsevier B.V. All rights reserved.
Déclaration de conflit d'intérêts