Ultrasonography for confirmation of gastric tube placement.


Journal

The Cochrane database of systematic reviews
ISSN: 1469-493X
Titre abrégé: Cochrane Database Syst Rev
Pays: England
ID NLM: 100909747

Informations de publication

Date de publication:
25 Jul 2024
Historique:
medline: 26 7 2024
pubmed: 26 7 2024
entrez: 25 7 2024
Statut: epublish

Résumé

Gastric tubes are commonly used for the administration of drugs and tube feeding for people who are unable to swallow. Feeding via a tube misplaced in the trachea can result in severe pneumonia. Therefore, the confirmation of tube placement in the stomach after tube insertion is important. Recent studies have reported that ultrasonography provides good diagnostic accuracy estimates in the confirmation of appropriate tube placement. Hence, ultrasound could provide a promising alternative to X-rays in the confirmation of tube placement, especially in settings where X-ray facilities are unavailable or difficult to access. To assess the diagnostic accuracy of ultrasound alone or in combination with other methods for gastric tube placement confirmation in children and adults. This systematic review is an update of a previously published Cochrane review. For this update, we searched the Cochrane Library (2021, Issue 6), MEDLINE (to April 2023), Embase (to April 2023), five other databases (to July 2021), and reference lists of articles, and contacted study authors. We included studies that evaluated the diagnostic accuracy of naso- and orogastric tube placement confirmed by ultrasound visualization using X-ray visualization as the reference standard. We included cross-sectional studies and case-control studies. We excluded case series or case reports. We excluded studies if X-ray visualization was not the reference standard or if the tube being placed was a gastrostomy or enteric tube. Two review authors independently assessed the methodological quality and extracted data from each of the included studies. We contacted the authors of the included studies to obtain missing data. There were sparse data for specificity. Therefore, we performed a meta-analysis of only sensitivity using a univariate random-effects logistic regression model to combine data from studies that used the same method and echo window. We identified 12 new studies in addition to 10 studies included in the earlier version of this review, totalling 1939 participants and 1944 tube insertions. Overall, we judged the risk of bias in the included studies as low or unclear. No study was at low risk of bias or low concern for applicability in every QUADAS-2 domain. There were limited data (152 participants) for misplacement detection (specificity) due to the low incidence of misplacement. The summary sensitivity of ultrasound on neck and abdomen echo windows were 0.96 (95% confidence interval (CI) 0.92 to 0.98; moderate-certainty evidence) for air injection and 0.98 (95% CI 0.83 to 1.00; moderate-certainty evidence) for saline injection. The summary sensitivity of ultrasound on abdomen echo window was 0.96 (95% CI 0.65 to 1.00; very low-certainty evidence) for air injection and 0.97 (95% CI 0.95 to 0.99; moderate-certainty evidence) for procedures without injection. The certainty of evidence for specificity across all methods was very low due to the very small sample size. For settings where X-ray was not readily available and participants underwent gastric tube insertion for drainage (8 studies, 552 participants), sensitivity estimates of ultrasound in combination with other confirmatory tests ranged from 0.86 to 0.98 and specificity estimates of 1.00 with wide CIs. For studies of ultrasound alone (9 studies, 782 participants), sensitivity estimates ranged from 0.77 to 0.98 and specificity estimates were 1.00 with wide CIs or not estimable due to no occurrence of misplacement. Of 22 studies that assessed the diagnostic accuracy of gastric tube placement, few studies had a low risk of bias. Based on limited evidence, ultrasound does not have sufficient accuracy as a single test to confirm gastric tube placement. However, in settings where X-ray is not readily available, ultrasound may be useful to detect misplaced gastric tubes. Larger studies are needed to determine the possibility of adverse events when ultrasound is used to confirm tube placement.

Sections du résumé

BACKGROUND BACKGROUND
Gastric tubes are commonly used for the administration of drugs and tube feeding for people who are unable to swallow. Feeding via a tube misplaced in the trachea can result in severe pneumonia. Therefore, the confirmation of tube placement in the stomach after tube insertion is important. Recent studies have reported that ultrasonography provides good diagnostic accuracy estimates in the confirmation of appropriate tube placement. Hence, ultrasound could provide a promising alternative to X-rays in the confirmation of tube placement, especially in settings where X-ray facilities are unavailable or difficult to access.
OBJECTIVES OBJECTIVE
To assess the diagnostic accuracy of ultrasound alone or in combination with other methods for gastric tube placement confirmation in children and adults.
SEARCH METHODS METHODS
This systematic review is an update of a previously published Cochrane review. For this update, we searched the Cochrane Library (2021, Issue 6), MEDLINE (to April 2023), Embase (to April 2023), five other databases (to July 2021), and reference lists of articles, and contacted study authors.
SELECTION CRITERIA METHODS
We included studies that evaluated the diagnostic accuracy of naso- and orogastric tube placement confirmed by ultrasound visualization using X-ray visualization as the reference standard. We included cross-sectional studies and case-control studies. We excluded case series or case reports. We excluded studies if X-ray visualization was not the reference standard or if the tube being placed was a gastrostomy or enteric tube.
DATA COLLECTION AND ANALYSIS METHODS
Two review authors independently assessed the methodological quality and extracted data from each of the included studies. We contacted the authors of the included studies to obtain missing data. There were sparse data for specificity. Therefore, we performed a meta-analysis of only sensitivity using a univariate random-effects logistic regression model to combine data from studies that used the same method and echo window.
MAIN RESULTS RESULTS
We identified 12 new studies in addition to 10 studies included in the earlier version of this review, totalling 1939 participants and 1944 tube insertions. Overall, we judged the risk of bias in the included studies as low or unclear. No study was at low risk of bias or low concern for applicability in every QUADAS-2 domain. There were limited data (152 participants) for misplacement detection (specificity) due to the low incidence of misplacement. The summary sensitivity of ultrasound on neck and abdomen echo windows were 0.96 (95% confidence interval (CI) 0.92 to 0.98; moderate-certainty evidence) for air injection and 0.98 (95% CI 0.83 to 1.00; moderate-certainty evidence) for saline injection. The summary sensitivity of ultrasound on abdomen echo window was 0.96 (95% CI 0.65 to 1.00; very low-certainty evidence) for air injection and 0.97 (95% CI 0.95 to 0.99; moderate-certainty evidence) for procedures without injection. The certainty of evidence for specificity across all methods was very low due to the very small sample size. For settings where X-ray was not readily available and participants underwent gastric tube insertion for drainage (8 studies, 552 participants), sensitivity estimates of ultrasound in combination with other confirmatory tests ranged from 0.86 to 0.98 and specificity estimates of 1.00 with wide CIs. For studies of ultrasound alone (9 studies, 782 participants), sensitivity estimates ranged from 0.77 to 0.98 and specificity estimates were 1.00 with wide CIs or not estimable due to no occurrence of misplacement.
AUTHORS' CONCLUSIONS CONCLUSIONS
Of 22 studies that assessed the diagnostic accuracy of gastric tube placement, few studies had a low risk of bias. Based on limited evidence, ultrasound does not have sufficient accuracy as a single test to confirm gastric tube placement. However, in settings where X-ray is not readily available, ultrasound may be useful to detect misplaced gastric tubes. Larger studies are needed to determine the possibility of adverse events when ultrasound is used to confirm tube placement.

Identifiants

pubmed: 39051488
doi: 10.1002/14651858.CD012083.pub3
doi:

Types de publication

Systematic Review Journal Article Meta-Analysis Review

Langues

eng

Sous-ensembles de citation

IM

Pagination

CD012083

Informations de copyright

Copyright © 2024 The Cochrane Collaboration. Published by John Wiley & Sons, Ltd.

Auteurs

Yasushi Tsujimoto (Y)

Department of Health Promotion and Human Behavior, Kyoto University Graduate School of Medicine/School of Public Health, Kyoto, Japan.
Oku Medical Clinic, Osaka, Japan.
Scientific Research WorkS Peer Support Group (SRWS-PSG), Osaka, Japan.

Yuki Kataoka (Y)

Scientific Research WorkS Peer Support Group (SRWS-PSG), Osaka, Japan.
Department of Internal Medicine, Kyoto Min-Iren Asukai Hospital, Kyoto, Japan.
Section of Clinical Epidemiology, Department of Community Medicine, Kyoto University Graduate School of Medicine, Kyoto, Japan.
Department of Healthcare Epidemiology, Kyoto University Graduate School of Medicine / School of Public Health, Kyoto, Japan.

Masahiro Banno (M)

Scientific Research WorkS Peer Support Group (SRWS-PSG), Osaka, Japan.
Department of Psychiatry, Seichiryo Hospital, Nagoya, Japan.

Keisuke Anan (K)

Scientific Research WorkS Peer Support Group (SRWS-PSG), Osaka, Japan.
Department of Healthcare Epidemiology, Kyoto University Graduate School of Medicine / School of Public Health, Kyoto, Japan.
Division of Respiratory Medicine, Saiseikai Kumamoto Hospital, Kumamoto, Japan.

Akihiro Shiroshita (A)

Scientific Research WorkS Peer Support Group (SRWS-PSG), Osaka, Japan.
Department of Respiratory Medicine, Ichinomiyanishi Hospital, Ichinomiya, Japan.

Satoshi Jujo (S)

Scientific Research WorkS Peer Support Group (SRWS-PSG), Osaka, Japan.
Department of Critical Care Medicine, St. Luke's International Hospital, Tokyo, Japan.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH