Department of Oral and Maxillofacial Surgery, School of Dentistry, Pusan National University, Yangsan, Korea; (Bio)medical Research Institute, Pusan National University Hospital, Busan, Korea.
Department of Oral and Maxillofacial Surgery, School of Dentistry, Pusan National University, Yangsan, Korea; Institute of Translational Dental Sciences & Dental Research Institute, Pusan National University, Yangsan, Korea. Electronic address: Omsljy@pusan.ac.kr.
Pain Research, MSk Lab, Department of Surgery and Cancer, Imperial College, London, United Kingdom.
Division of Neurological Pain Research and Therapy, Department of Neurology, University Hospital Schleswig-Holstein, Campus Kiel, Germany.
Department of Anaesthesiology, Intensive Care and Pain Medicine, University Hospital Muenster, Münster, Germany.
Department of Neurophysiology, Mannheim Center for Translational Neuroscience MCTN, Medical Faculty Mannheim, Ruprecht Karls University, Heidelberg, Germany.
INSERM U-987, Centre d'Evaluation et de Traitement de la Douleur, CHU Ambroise Paré, Boulogne-Billancourt, France, Université Versailles-Saint-Quentin, Versailles, France.
INSERM U-987, Centre d'Evaluation et de Traitement de la Douleur, CHU Ambroise Paré, Boulogne-Billancourt, France, Université Versailles-Saint-Quentin, Versailles, France.
This study aimed to compare the mechanical properties of various occlusal plate materials by analyzing surface roughness, Knoop microhardness, flexural strength, and modulus of elasticity. Fifty sampl...
The aim of this in vitro study was to evaluate the wear and surface hardness of nine materials for conventional manufacturing, subtractive milling, and 3D printing of occlusal splints, as well as to e...
Poly-(etheretherketone) (PEEK) began to be used in the field of odontology more than 10 years ago, especially in relation to the creation of removable partial dentures. Here we report the case of a 62...
Occlusal devices used to manage bruxism have been commonly fabricated from polymethyl methacrylate with the powder-liquid technique. More recently, Vertex ThermoSens (VTS) and the biocompatible high-p...
The purpose of this in vitro study was to assess via a mastication simulation test how 3 occlusal device materials affected the wear and roughness of enamel antagonists....
A noncontact 3D optical profilometer was used to measure the enamel surface roughness (Ra) against 3 occlusal device materials: vertex regular, VTS, and PEEK high-performance polymer (BioHPP). A dual-...
The polyamide group caused the lowest amount of enamel wear (P<.05), while the heat-polymerized acrylic resin group induced the largest amount of enamel wear (P<.05). For polyamide and PEEK, the chang...
According to this study, surface roughness and wear on human enamel were not correlated. PEEK is a promising material for the fabrication of occlusal devices....
To investigate the effects of the manufacturing technologies on the surface (cameo and intaglio) accuracy (trueness and precision) of computer-aided design and computer-aided manufacturing (CAD-CAM) o...
The digital design of the master occlusal splint was designed in a CAD software program. Six groups (n = 10) were tested in this study, including Group 1 - Milling (Wax), Group 2 - Heat-polymerizing, ...
The null hypotheses were rejected. The manufacturing technologies significantly affected the trueness of occlusal splints at both intaglio and cameo surfaces (p < 0.001). At the cameo surfaces, Group ...
The manufacturing technologies significantly affected the trueness and precision of occlusal splints at both intaglio and cameo surfaces. The 5-axis milling units and industrial-level CLIP 3D-printer ...
This clinical trial aims to compare the accuracy of interocclusal registration in centric relation taken with polyvinyl siloxane and intraoral scanner (IOS) with the fabrication of occlusal devices....
Thirty-one participants were included in the trial registered at ClinicalTrials.gov (NCT05317182) receiving two different occlusal devices from two different workflows. One workflow was performed usin...
The average values of RMS were higher for the analog approach (0.01 ± 0.067) than the digital approach (0.065 ± 0.035). However, the differences were not statistically significant (p < 0.063) between ...
Digital impressions did not show inferior accuracy compared to conventional impressions when assessed using quantitative measurements....
This clinical trial provided evidence on registering interocclusal relationship at increased vertical dimension with fully digital workflow for complete arch prosthesis....
Scientific evidence pertaining to the evaluation of trueness of occlusal splints fabricated using different three-dimensional (3D) printers and build orientations compared to subtractive technologies ...
Overall, one hundred and ten occlusal splints were manufactured using two different 3D printers and a dental mill. Five groups of ten were fabricated using the 3D printers at different build orientati...
The 0 degree printing orientation was the most accurate for printer one with the root mean square value of 0.05 ± 0.01 mm, and 60 degree printing orientation was most accurate for printer two with the...
Build orientations influence the trueness of additively manufactured occlusal splints while occlusal splints produced by subtractive manufacturing were statistically significantly more accurate....
Precise orthognathic surgical splints are important in surgical-orthodontic treatment. This study aimed to propose a standardized protocol for three-dimensional (3D)-printed splints and assess the pre...
Resin models in optimal occlusion from 19 patients were selected and scanned. Intermediate splints (ISs) and final splints (FSs) with 2-mm, 3-mm, 4-mm, and 5-mm OCDs were fabricated and grouped as IS-...
For vertical translation, the lower dentitions translated inferiorly to the upper dentition in most of the splints, and the translation increased as OCD got larger. Vertical translations of the dentit...
A protocol was proposed to generate 3D-printed ISs and FSs with normalized basal planes and standardized OCDs. Deviations of the ISs and FSs were more evident in the vertical dimension and pitch rotat...
Body posture of patients with temporomandibular disorders (TMD) has been investigated using different methods, whereas outcome and conclusions were controversial. The present clinical trial aimed to i...
24 subjects (20 females, 4 males; age 24.2 ± 4.0 years) with TMD symptoms were examined clinically (RDC/TMD) and subsequently, splint fabrication was initiated. Along with routine therapy, all subject...
The increase of Forward Head angles and the decrease of Round Shoulders angles were consistent for both positions and sides. Forward Head angles were significantly influenced by limited mandibular mob...
The influence of occlusal splints on global posture is limited and only small effects on cervicocranial parameters were found. In the present study, the average head position of post treatment measure...
Understanding the limited influence of occlusal splints on cervicocranial parameters underscores the need for multimodal treatment strategies for TMD patients....
To assess (1) whether an occlusal splint (OS) or mandibular advancement splint (MAS) allowed better sleep quality and was more comfortable in individuals with sleep bruxism (SB); and (2) the relations...
Polysomnographic data from 21 SB subjects (mean ± SD age 25.6 ± 4.5 years) collected in two previous studies were compared. Morning self-reports on sleep quality and comfort of the oral device, polyso...
Self-reports for sleep quality and comfort of the oral device showed a mild advantage of the OS when compared to the MAS (r...
In the short term, the comfort of the oral device seemed to influence sleep quality in SB individuals. However, despite the slightly higher degree of comfort offered by the OS, the MAS induced a great...