Center for Gun Violence Prevention and Policy, Department of Health Policy and Management, Johns Hopkins Bloomberg School of Public Health, Baltimore, USA. Electronic address: crifasi@jhu.edu.
Center for Gun Violence Prevention and Policy, Department of Health Policy and Management, Johns Hopkins Bloomberg School of Public Health, Baltimore, USA.
Center for Gun Violence Prevention and Policy, Department of Health Policy and Management, Johns Hopkins Bloomberg School of Public Health, Baltimore, USA.
Center for Gun Violence Prevention and Policy, Department of Health Policy and Management, Johns Hopkins Bloomberg School of Public Health, Baltimore, USA; Cornell Jeb E. Brooks School of Public Policy, USA.
Center for Gun Violence Prevention and Policy, Department of Health Policy and Management, Johns Hopkins Bloomberg School of Public Health, Baltimore, USA.
This study aimed to quantify forearm kinematics with a focus on the forearm rotation axis. Ten healthy volunteers were included in the study. One three-dimensional computed tomographic scan and two fo...
Pleural adhesions are challenging during lung cancer surgery and may be associated with a long surgery time and excessive blood loss due to pleural adhesiolysis. We used preoperative four-dimensional ...
A total of 216 patients with lung cancer underwent four-dimensional computed tomography during the study period. Pleural adhesions were subsequently confirmed by surgery in 85 of these patients, where...
The movement of (α) was smaller in patients with adhesions than in those without adhesions. The greater the adhesion, the shorter the movement distance (p < 0.001). Receiver-operating characteristic c...
Four-dimensional computed tomography is a novel and helpful modality for predicting the presence of parietal pleural adhesions. To obtain robust evidence, further accumulation of cases and re-examinat...
This study explored the application of four-dimensional cone beam computed tomography (4D CBCT) in lung cancer patients, seeking to improve the accuracy of radiotherapy and to establish a uniform prot...
4D CBCT was applied to evaluate tumor volume response (TVR), motion, and center coordinates during radiotherapy in 67 eligible individuals with lung cancer diagnoses. The differences between 4D CBCT a...
TVR was observed during treatment in 41% of patients (28/67), with a mean volume reduction of 41.7% and a median time to TVR of 19 days. Tumor motion was obvious in 16 patients, with a mean value of 0...
Tumor volume and motion of intrapulmonary lesions in individuals diagnosed with lung cancer varied significantly in the third week of radiotherapy. 4D CBCT may be more advantageous for isolated lesion...
In the analysis of the shoulder complex, the sequential changes occurring in the sternoclavicular and acromioclavicular joints during active shoulder motion are challenging to track. This study aimed ...
Standard four-dimensional computed tomography (4DCT) cardiac reconstructions typically include spiraling artifacts that depend not only on the motion of the heart but also on the gantry angle range ov...
We use a motion artifact reduction approach (ResyncCT) that is based largely on conjugate pairs of partial angle reconstruction (PAR) images. After identifying the key locations where motion artifacts...
The results from our preliminary phantom test as well as from clinical cardiac scans show crisp endocardial edges and resolved double-wall artifacts. When viewed as a temporal series, the corrected im...
The ResyncCT algorithm was shown to be effective in reducing motion artifacts and restoring accurate wall positions. Some perspectives on the use of conjugate-PAR images and on techniques for CT motio...
Although four-dimensional cone-beam computed tomography (4D-CBCT) is valuable to provide onboard image guidance for radiotherapy of moving targets, it requires a long acquisition time to achieve suffi...
In this work, we aim to propose an alternative feature-compensated method to realize the fast 4D-CBCT with high-quality images....
We proposed a feature-compensated deformable convolutional network (FeaCo-DCN) to perform interphase compensation in the latent feature space, which has not been explored by previous studies. In FeaCo...
(1) FeaCo-DCN generated high-quality images with accurate and clear structures for a fast 4D-CBCT scan; (2) 4D-CBCT images reconstructed by FeaCo-DCN achieved 3D tumor localization accuracy within 2.5...
The proposed FeaCo-DCN is effective and efficient in reconstructing 4D-CBCT while reducing about 90% of the scanning time, which can be highly valuable for moving target localization in image-guided r...
The dynamic regional accuracy of electrical impedance tomography has not yet been validated. We aimed to compare the regional accuracy of electrical impedance tomography with that of four-dimensional ...
This single-center, prospective, observational study conducted in a general intensive care unit included adult patients receiving mechanical ventilation from July 2021 to February 2024. The patients w...
Overall, 45 patients were analyzed. The correlation coefficients in regional dynamic ventilation between four-dimensional computed tomography and electrical impedance tomography in each region were 0....
Regional ventilation using electrical impedance tomography during dynamic ventilation was highly accurate and consistent with the time phase compared to four-dimensional computed tomography. Given the...
CT imaging precisely and quantitatively analyzes the kinematics of the carpal bones to evaluate the etiology of related osteoarthritis. Previous studies have investigated the kinematics of the trapezi...
Twelve healthy young volunteers participated in this study. Each participant held the pinch meter between their thumb and index finger and pinched it with maximum force for a period of 6 s. This serie...
The first metacarpal was abducted (15.9 ± 8.3°) and flexed (12.2 ± 7.1°) relative to the trapezium, and significantly translated to the volar (0.8 ± 0.6 mm) and ulnar directions (0.9 ± 0.8 mm) with ma...
This study successfully employed 4D-CT to precisely demonstrate changes in rotation and translation at the trapeziometacarpal joint during pinch motion for various instantaneous forces....
Current computed tomography (CT)-based lung ventilation imaging (CTVI) techniques derive a static ventilation image without temporal information. This research aims to develop a four-dimensional CT (4...
A total of 15 free-breathing thoracic 4DCT scans of lung or esophageal cancer patients were collected from the public datasets. The lung region of each phase image was first delineated, and then the m...
The proposed method maintains the physiological meaning of ventilation on each phase and enables to recover the dynamic lung ventilation process. The mean interphase Spearman correlations ranged betwe...
In contrast to conventional CTVI metrics, our method enables to extract additional phase-resolved respiration-correlated information and reflects the generally existed ventilation spatiotemporal heter...
Motion-compensated (MoCo) reconstruction shows great promise in improving four-dimensional cone-beam computed tomography (4D-CBCT) image quality. MoCo reconstruction for a 4D-CBCT could be more accura...
This study aims to develop a deep-learning method to generate high-quality motion models for MoCo reconstruction to improve the quality of final 4D-CBCT images....
A 3D artifact-reduction convolutional neural network (CNN) was proposed to improve conventional phase-correlated Feldkamp-Davis-Kress (PCF) reconstructions by reducing undersampling-induced streaking ...
The trained CNN effectively reduced the streaking artifacts of PCF CBCT images for all datasets. More detailed structures can be recovered using the proposed CNN+MoCo reconstruction procedure. XCAT ph...
CNN-based artifact reduction can substantially reduce the artifacts in the initial 4D-CBCT images. The improved images could be used to enhance the motion modeling and ultimately improve the quality o...