Department of Dental Materials, Faculty of Dentistry, Asian Institute of Medicine, Science and Technology (AIMST) University, 08100, Bedong, Kedah, Malaysia. gaelvylin@yahoo.com.
Department of Pediatric Dentistry, Orthodontics and Community Dentistry, Discipline of Pediatric Dentistry, Bauru School of Dentistry-University of São Paulo, Bauru, Brazil; Hospital for the Rehabilitation of Craniofacial Anomalies, University of São Paulo, Bauru, Brazil.
State Key Laboratory of Military Stomatology & National Clinical Research Center for Oral Diseases & Shaanxi Key Laboratory of Oral Diseases, Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, 145 Changle West Road, Xi'an, Shaanxi 710032, PR China.
Department of General Dentistry, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices & Beijing Key Laboratory of Digital Stomatology & NHC Research Center of Engineering and Technology for Computerized Dentistry & NMPA Key Laboratory for Dental Materials, Beijing 100081, China.
Department of General Dentistry, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices & Beijing Key Laboratory of Digital Stomatology & NHC Research Center of Engineering and Technology for Computerized Dentistry & NMPA Key Laboratory for Dental Materials, Beijing 100081, China.
Department of General Dentistry, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices & Beijing Key Laboratory of Digital Stomatology & NHC Research Center of Engineering and Technology for Computerized Dentistry & NMPA Key Laboratory for Dental Materials, Beijing 100081, China.
Department of General Dentistry, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices & Beijing Key Laboratory of Digital Stomatology & NHC Research Center of Engineering and Technology for Computerized Dentistry & NMPA Key Laboratory for Dental Materials, Beijing 100081, China.
Department of General Dentistry, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices & Beijing Key Laboratory of Digital Stomatology & NHC Research Center of Engineering and Technology for Computerized Dentistry & NMPA Key Laboratory for Dental Materials, Beijing 100081, China.
Department of General Dentistry, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices & Beijing Key Laboratory of Digital Stomatology & NHC Research Center of Engineering and Technology for Computerized Dentistry & NMPA Key Laboratory for Dental Materials, Beijing 100081, China.
Most neuroimaging studies display results that represent only a tiny fraction of the collected data. While it is conventional to present "only the significant results" to the reader, here we suggest t...
To evaluate the multi-vendor multi-site reproducibility of two-dimensional (2D) multi-echo spin-echo (MESE) T...
Phantoms and volunteers (n = 5 from each site, n = 20 in total) were scanned on four 3 T magnetic resonance (MR) systems from four sites and three vendors (Siemens, General Electric, and Phillips). Tw...
For baseline 2D MESE T...
This study demonstrated excellent intra-site reproducibility of 2D MESE T...
The setup, operational procedures and performance of a cryogen-free device for producing hyperpolarized contrast agents using dissolution dynamic nuclear polarization (dDNP) in a preclinical imaging c...
Small-...
We provide a tutorial on reproducible analyses of small-...
Reproducible code demonstrates implementation and comparison of within-case standardized mean difference, proportion of maximal gain, tau-U, and frequentist and Bayesian mixed-effects models. Data, co...
Pursuing reproducible research is key to promoting transparency in small-...
Continuous glucose monitoring systems (CGM) are a very useful tool to understand the behaviour of glucose in different situations and populations. Despite the widespread use of CGM systems in both cli...
Estimate the reproducibility of hearing screening results using the uHear™ smartphone-based app in two response modes: self-test response and test-operator....
Reliability study conducted with 65 individuals aged ≥18 years assisted at the Speech-language and Hearing Therapy clinic of a public higher-education institution. Hearing screening was conducted by a...
A correspondence of ±5 dBHL >75% was observed between these hearing thresholds. The ICC values showed excellent agreement between the two response modes at all frequencies >40 dBHL tested....
The two hearing screening response modes using the uHear app presented high reproducibility, suggesting that the test-operator mode is a viable alternative when the self-test response mode is not reco...
Increasing the reproducibility of research should be a top priority. Great work is being done, but more work is needed to combine efforts and maximize our actions to enable true reproducibility reform...
In biomedical research, validating a scientific discovery hinges on the reproducibility of its experimental results. However, in genomics, the definition and implementation of reproducibility remain i...
To assess the accuracy, repeatability, and reproducibility of T...
The ISMRM/NIST phantom was scanned daily for 10 days in two 3 T MR scanners using a 3D MRF sequence reconstructed using four dictionaries with varying step sizes and one dictionary with wider ranges. ...
In the phantom study, all dictionaries showed high T...
The accuracy, repeatability, and reproducibility of 3D MRF across various dictionary resolutions were high for T...
• A lower-resolution dictionary with a well-defined range may be sufficient for 3D MRF reconstruction. • CSF relaxation times might be underestimated due to truncation by the upper dictionary range. •...