College of Earth and Planetary Sciences, University of Chinese Academy of Sciences, Beijing, China.
Laboratory for Marine Biology and Biotechnology, Pilot National Laboratory for Marine Science and Technology (Qingdao), Qingdao, China.
CAS and Shandong Province Key Laboratory of Experimental Marine Biology, Institute of Oceanology, Center for Ocean Mega-Science, Chinese Academy of Sciences, Qingdao, China.
Laboratory for Marine Biology and Biotechnology, Pilot National Laboratory for Marine Science and Technology (Qingdao), Qingdao, China.
CAS and Shandong Province Key Laboratory of Experimental Marine Biology, Institute of Oceanology, Center for Ocean Mega-Science, Chinese Academy of Sciences, Qingdao, China.
Laboratory for Marine Biology and Biotechnology, Pilot National Laboratory for Marine Science and Technology (Qingdao), Qingdao, China.
CAS and Shandong Province Key Laboratory of Experimental Marine Biology, Institute of Oceanology, Center for Ocean Mega-Science, Chinese Academy of Sciences, Qingdao, China.
Deep Sea Research Center, Institute of Oceanology, Chinese Academy of Sciences, Qingdao, China.
Laboratory for Marine Biology and Biotechnology, Pilot National Laboratory for Marine Science and Technology (Qingdao), Qingdao, China.
CAS and Shandong Province Key Laboratory of Experimental Marine Biology, Institute of Oceanology, Center for Ocean Mega-Science, Chinese Academy of Sciences, Qingdao, China.
Laboratory for Marine Biology and Biotechnology, Pilot National Laboratory for Marine Science and Technology (Qingdao), Qingdao, China.
CAS and Shandong Province Key Laboratory of Experimental Marine Biology, Institute of Oceanology, Center for Ocean Mega-Science, Chinese Academy of Sciences, Qingdao, China.
Laboratory for Marine Biology and Biotechnology, Pilot National Laboratory for Marine Science and Technology (Qingdao), Qingdao, China.
CAS and Shandong Province Key Laboratory of Experimental Marine Biology, Institute of Oceanology, Center for Ocean Mega-Science, Chinese Academy of Sciences, Qingdao, China.
Department of Biochemistry, Cancer Institute of the Second Affiliated Hospital (Key Laboratory of Cancer Prevention and Intervention, China National Ministry of Education), School of Medicine, Zhejiang University, Hangzhou, China.
Department of Biochemistry, Cancer Institute of the Second Affiliated Hospital (Key Laboratory of Cancer Prevention and Intervention, China National Ministry of Education), School of Medicine, Zhejiang University, Hangzhou, China.
Department of Biochemistry, Cancer Institute of the Second Affiliated Hospital (Key Laboratory of Cancer Prevention and Intervention, China National Ministry of Education), School of Medicine, Zhejiang University, Hangzhou, China.
Department of Biochemistry, Cancer Institute of the Second Affiliated Hospital (Key Laboratory of Cancer Prevention and Intervention, China National Ministry of Education), School of Medicine, Zhejiang University, Hangzhou, China.
Department of Biochemistry, Cancer Institute of the Second Affiliated Hospital (Key Laboratory of Cancer Prevention and Intervention, China National Ministry of Education), School of Medicine, Zhejiang University, Hangzhou, China.
In passive middle ear prosthetics, rigid implants have proven successful in reconstructing the ossicular chain. However, these cannot fully replicate the physiology of the ossicular chain. Pressure fl...
In collaboration with MED-EL, we developed a new passive middle ear prosthesis that features a balanced, centered ball joint between the headplate and shaft of the prosthesis. We compared the sound tr...
The new prosthesis showed equivalent sound transmission characteristics compared to the rigid prosthesis, whereas retaining the ability to compensate for pressure fluctuations due to its ball joint. T...
This development is a further step toward a physiological reconstruction of the ossicular chain....
NA Laryngoscope, 133:1717-1721, 2023....
Comparison of the hearing outcomes of titanium partial ossicular replacement prosthesis (PORP) vs. titanium total ossicular replacement prosthesis (TORP) with footplate shoe (Omega Connector) in secon...
In this retrospective cohort study in a tertiary hospital, we compared the hearing outcomes in 248 patients who had undergone ossicular chain reconstruction with titanium prostheses PORP (n = 115) vs....
In general, we found that there were no significant differences between PORP and TORP groups in gains of BC (P = 0.080), AC (P = 0.454), ABG (P = 0.928), SRT (P = 0.065), and SDS (P = 0.363). There we...
To sum up, this research provided additional evidence with respect to hearing outcomes after staged ossicular chain reconstruction with PORP and TORP. The practical application of our study is that TO...
To evaluate whether bilateral congenital ossicular anomalies (COAs) differ regarding ossicular anomalies and hearing loss severities between the ears of the individual....
Retrospective case review....
Tertiary referral academic center....
Between March 2012 and December 2022, 7 consecutive patients (14 ears) with surgically confirmed bilateral COAs were included in the study. Preoperative pure-tone thresholds, COA classification accord...
The median age of the patients was 11.5 (range: 6-25) years. Both ears of each patient were categorized based on the same classification. Three patients possessed class III COAs and the other 4 had cl...
The severity of ossicular abnormalities and hearing loss in patients with bilateral COAs were symmetrical between ears, thereby enabling prediction of the characteristics of the contralateral ear base...
This review sought to establish expectations for hearing improvement with specifically titanium partial (PORP) and total ossicular replacement prostheses (TORP) to give surgeons an acceptable goal for...
MEDLINE/PubMed, EMBASE, and Cochrane Library....
A systematic review of the literature was performed per the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Three databases (MEDLINE/PubMed, EMBASE, Cochrane library) we...
Forty articles were analyzed after full article review based on the inclusion and exclusion criteria. For PORPs, the average improvement in air-bone gap (ABG) and pure-tone average were 12.1 and 13.5 ...
Overall, reconstruction of the ossicular chain with titanium prostheses reliably improves patients' hearing outcomes, and this study gives relevant information for counseling patients preoperatively o...
Ossiculoplasty is aimed at improving or maintaining the conductive portion of hearing in patients subjected to otologic surgery. However, satisfying hearing is frequently observed after tympanoplasty ...
Retrospective chart review of patients who underwent ear surgery from year 2003 to 2021 at the Otolaryngology-Head and Neck surgery department of the University Hospital of Modena was performed. Audio...
Tertiary University referral center....
The mean patients' follow-up was 34.1 months. Overall, mean PTA-ABG in the study population was 23.5 dB. Integrity of stapes superstructure, malleus handle and malleus head, together with the use of t...
Good hearing performance can be obtained in patients subjected to middle ear surgery, even if the ossicular chain is not reconstructed. Presence of ossicular chain remnants and the use of a rigid mate...
To review hearing and surgical outcomes after reconstructive middle ear surgery in class 4 congenital middle ear anomalies (CMEA), e.g., patients with oval- or round window atresia of dysplasia....
Pubmed/Medline, Embase and Cochrane library....
Articles containing data on hearing outcomes and complications after reconstructive ear surgery in class 4 anomalies were analyzed and critically appraised. The following data were included and review...
Success rates varied from 12.5 to 75% at long-term follow-up with larger cohorts reporting success rates around 50%, mean postoperative gain in AC varied from 4.7 to 30 dB and - 8.6 to 23.6 dB at, res...
Reconstructive surgery can be an effective treatment option which should be considered in patients with very favorable baseline parameters, while also considering the substantial risk of recurrence of...
2c....
Middle ear surgery involves reconstruction of the ossicular chain, predominately using rigid implants. New middle ear prostheses strive to mimic the physiologic micromovements of the ossicular chain a...
Thirty-five patients were included in a monocentric, prospective observational study. Patients received tympanoplasty with ossicular reconstruction using the mCLIP ARC partial prosthesis. This titaniu...
The new prosthesis shows favorable clinical results. Pure-tone audiometry showed satisfactory results in ST and MT follow-up, with the PTA4 air-bone gap (ABG) decreasing from 24.5 (±11) dB to 17.4 (±7...
The mCLIP ARC partial prosthesis, a new middle ear prosthesis with a balanced ball joint, shows promising audiological results and is a safe and effective choice for patients with chronic ear disease....
3 Laryngoscope, 2024....
This multicentric, retrospective study aimed to analyze the short-term safety and effectiveness of the mCLIP Partial Prosthesis....
Patients underwent tympanoplasty with implantation of a mCLIP Partial Prosthesis. Follow-up examination included ear microscopy and pure-tone audiometry to determine the post-operative pure tone avera...
72 (66 adults, 6 children) patients were implanted with the mCLIP Partial Prosthesis. 68 (62 adults, 6 children) patients underwent audiological examination; all 72 patients were examined for adverse ...
Clinical data show satisfactory audiological parameters after implantation of the mCLIP Partial Prosthesis. The prosthesis is safe and effective for implantation in children and adults....
NCT05565339, 09 September 2022, retrospectively registered....
In reconstructive middle ear surgery, acoustic quality has received a high level of attention in recent years. Careful intraoperative selection and positioning of passive middle ear prostheses during ...
Laser Doppler vibrometry (LDV) was used to measure the middle ear transfer function (METF) in 18 human temporal bones (TB). The RTM system uses electromagnetic excitation of the OC with a magnet place...
Electromagnetic and acoustic excitation of the intact and the reconstructed OC provided comparable METF. The application of the RTM system significantly improved the quality of the OC reconstruction. ...
In this TB study, we demonstrated that the quality of OC reconstruction (improved METF as a benchmark for improved transmission) could be significantly increased by means of a RTM system. Intraoperati...
Different techniques are used to fix crimp and CliP® Piston stapes prostheses to the long process of the incus (LPI). The CliP® Piston provides a stiff connection in contrast to the static bended loop...
In a retrospective single-center study of German-speaking one hundred and ninety patients who underwent stapes surgery CliP® Piston or crimp prostheses between the years of 2016 and 2019 by the same s...
The postoperative bone conduction thresholds were significantly lower in the frequencies between 0.5 and 3 kHz and the mean ABG was < 10 dB in most cases independent of the prosthesis used. Crimp pros...
The audiological outcome after stapes surgery is dependent on the type of prosthesis used, as reflected by the frequency-specific air-bone gap. The better ABG closure with the crimp prosthesis might b...