questionsmedicales.fr
Équipement et fournitures
Prothèses et implants
Prothèses et implants : Questions médicales fréquentes
Termes MeSH sélectionnés :
Surgery, Computer-Assisted
{
"@context": "https://schema.org",
"@graph": [
{
"@type": "MedicalWebPage",
"name": "Prothèses et implants : Questions médicales les plus fréquentes",
"headline": "Prothèses et implants : Comprendre les symptômes, diagnostics et traitements",
"description": "Guide complet et accessible sur les Prothèses et implants : explications, diagnostics, traitements et prévention. Information médicale validée destinée aux patients.",
"datePublished": "2024-02-19",
"dateModified": "2025-02-13",
"inLanguage": "fr",
"medicalAudience": [
{
"@type": "MedicalAudience",
"name": "Grand public",
"audienceType": "Patient",
"healthCondition": {
"@type": "MedicalCondition",
"name": "Prothèses et implants"
},
"suggestedMinAge": 18,
"suggestedGender": "unisex"
},
{
"@type": "MedicalAudience",
"name": "Médecins",
"audienceType": "Physician",
"geographicArea": {
"@type": "AdministrativeArea",
"name": "France"
}
},
{
"@type": "MedicalAudience",
"name": "Chercheurs",
"audienceType": "Researcher",
"geographicArea": {
"@type": "AdministrativeArea",
"name": "International"
}
}
],
"reviewedBy": {
"@type": "Person",
"name": "Dr Olivier Menir",
"jobTitle": "Expert en Médecine",
"description": "Expert en Médecine, Optimisation des Parcours de Soins et Révision Médicale",
"url": "/static/pages/docteur-olivier-menir.html",
"alumniOf": {
"@type": "EducationalOrganization",
"name": "Université Paris Descartes"
}
},
"isPartOf": {
"@type": "MedicalWebPage",
"name": "Équipement et fournitures",
"url": "https://questionsmedicales.fr/mesh/D004864",
"about": {
"@type": "MedicalCondition",
"name": "Équipement et fournitures",
"code": {
"@type": "MedicalCode",
"code": "D004864",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07"
}
}
},
"hasPart": [
{
"@type": "MedicalWebPage",
"name": "Implant résorbable",
"alternateName": "Absorbable Implants",
"url": "https://questionsmedicales.fr/mesh/D020341",
"about": {
"@type": "MedicalCondition",
"name": "Implant résorbable",
"code": {
"@type": "MedicalCode",
"code": "D020341",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.025"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Bioprothèse",
"alternateName": "Bioprosthesis",
"url": "https://questionsmedicales.fr/mesh/D001705",
"about": {
"@type": "MedicalCondition",
"name": "Bioprothèse",
"code": {
"@type": "MedicalCode",
"code": "D001705",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.100"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Prothèse vasculaire",
"alternateName": "Blood Vessel Prosthesis",
"url": "https://questionsmedicales.fr/mesh/D001807",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse vasculaire",
"code": {
"@type": "MedicalCode",
"code": "D001807",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.110"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Prothèse à ancrage osseux",
"alternateName": "Bone-Anchored Prosthesis",
"url": "https://questionsmedicales.fr/mesh/D000077280",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse à ancrage osseux",
"code": {
"@type": "MedicalCode",
"code": "D000077280",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.118"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Interface os-implant",
"alternateName": "Bone-Implant Interface",
"url": "https://questionsmedicales.fr/mesh/D000069343",
"about": {
"@type": "MedicalCondition",
"name": "Interface os-implant",
"code": {
"@type": "MedicalCode",
"code": "D000069343",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.125"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Implants mammaires",
"alternateName": "Breast Implants",
"url": "https://questionsmedicales.fr/mesh/D018427",
"about": {
"@type": "MedicalCondition",
"name": "Implants mammaires",
"code": {
"@type": "MedicalCode",
"code": "D018427",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.140"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Prothèses dentaires",
"alternateName": "Dental Prosthesis",
"url": "https://questionsmedicales.fr/mesh/D017266",
"about": {
"@type": "MedicalCondition",
"name": "Prothèses dentaires",
"code": {
"@type": "MedicalCode",
"code": "D017266",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190"
}
},
"hasPart": [
{
"@type": "MedicalWebPage",
"name": "Couronnes",
"alternateName": "Crowns",
"url": "https://questionsmedicales.fr/mesh/D003442",
"about": {
"@type": "MedicalCondition",
"name": "Couronnes",
"code": {
"@type": "MedicalCode",
"code": "D003442",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.088"
}
},
"hasPart": [
{
"@type": "MedicalWebPage",
"name": "Restauration coronoradiculaire",
"alternateName": "Post and Core Technique",
"url": "https://questionsmedicales.fr/mesh/D011176",
"about": {
"@type": "MedicalCondition",
"name": "Restauration coronoradiculaire",
"code": {
"@type": "MedicalCode",
"code": "D011176",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.088.500"
}
}
}
]
},
{
"@type": "MedicalWebPage",
"name": "Restauration coronoradiculaire",
"alternateName": "Post and Core Technique",
"url": "https://questionsmedicales.fr/mesh/D011176",
"about": {
"@type": "MedicalCondition",
"name": "Restauration coronoradiculaire",
"code": {
"@type": "MedicalCode",
"code": "D011176",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.088.500"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Piliers dentaires",
"alternateName": "Dental Abutments",
"url": "https://questionsmedicales.fr/mesh/D000044",
"about": {
"@type": "MedicalCondition",
"name": "Piliers dentaires",
"code": {
"@type": "MedicalCode",
"code": "D000044",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.175"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Crochets dentaires",
"alternateName": "Dental Clasps",
"url": "https://questionsmedicales.fr/mesh/D016734",
"about": {
"@type": "MedicalCondition",
"name": "Crochets dentaires",
"code": {
"@type": "MedicalCode",
"code": "D016734",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.180"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Implants dentaires unitaires",
"alternateName": "Dental Implants, Single-Tooth",
"url": "https://questionsmedicales.fr/mesh/D019250",
"about": {
"@type": "MedicalCondition",
"name": "Implants dentaires unitaires",
"code": {
"@type": "MedicalCode",
"code": "D019250",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.183.185"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Prothèse dentaire implanto-portée",
"alternateName": "Dental Prosthesis, Implant-Supported",
"url": "https://questionsmedicales.fr/mesh/D019094",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse dentaire implanto-portée",
"code": {
"@type": "MedicalCode",
"code": "D019094",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.185"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Restaurations dentaires permanentes",
"alternateName": "Dental Restoration, Permanent",
"url": "https://questionsmedicales.fr/mesh/D003793",
"about": {
"@type": "MedicalCondition",
"name": "Restaurations dentaires permanentes",
"code": {
"@type": "MedicalCode",
"code": "D003793",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.190"
}
},
"hasPart": [
{
"@type": "MedicalWebPage",
"name": "Réparation de restauration dentaire",
"alternateName": "Dental Restoration Repair",
"url": "https://questionsmedicales.fr/mesh/D058250",
"about": {
"@type": "MedicalCondition",
"name": "Réparation de restauration dentaire",
"code": {
"@type": "MedicalCode",
"code": "D058250",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.190.250"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Inlays",
"alternateName": "Inlays",
"url": "https://questionsmedicales.fr/mesh/D007284",
"about": {
"@type": "MedicalCondition",
"name": "Inlays",
"code": {
"@type": "MedicalCode",
"code": "D007284",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.190.350"
}
}
}
]
},
{
"@type": "MedicalWebPage",
"name": "Réparation de restauration dentaire",
"alternateName": "Dental Restoration Repair",
"url": "https://questionsmedicales.fr/mesh/D058250",
"about": {
"@type": "MedicalCondition",
"name": "Réparation de restauration dentaire",
"code": {
"@type": "MedicalCode",
"code": "D058250",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.190.250"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Inlays",
"alternateName": "Inlays",
"url": "https://questionsmedicales.fr/mesh/D007284",
"about": {
"@type": "MedicalCondition",
"name": "Inlays",
"code": {
"@type": "MedicalCode",
"code": "D007284",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.190.350"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Restaurations dentaires temporaires",
"alternateName": "Dental Restoration, Temporary",
"url": "https://questionsmedicales.fr/mesh/D003794",
"about": {
"@type": "MedicalCondition",
"name": "Restaurations dentaires temporaires",
"code": {
"@type": "MedicalCode",
"code": "D003794",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.192"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Facettes dentaires",
"alternateName": "Dental Veneers",
"url": "https://questionsmedicales.fr/mesh/D003801",
"about": {
"@type": "MedicalCondition",
"name": "Facettes dentaires",
"code": {
"@type": "MedicalCode",
"code": "D003801",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.196"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Appareils de prothèse dentaire",
"alternateName": "Dentures",
"url": "https://questionsmedicales.fr/mesh/D003778",
"about": {
"@type": "MedicalCondition",
"name": "Appareils de prothèse dentaire",
"code": {
"@type": "MedicalCode",
"code": "D003778",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.200"
}
},
"hasPart": [
{
"@type": "MedicalWebPage",
"name": "Bases d'appareil de prothèse dentaire",
"alternateName": "Denture Bases",
"url": "https://questionsmedicales.fr/mesh/D003819",
"about": {
"@type": "MedicalCondition",
"name": "Bases d'appareil de prothèse dentaire",
"code": {
"@type": "MedicalCode",
"code": "D003819",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.200.200"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Prothèse dentaire complète",
"alternateName": "Denture, Complete",
"url": "https://questionsmedicales.fr/mesh/D003824",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse dentaire complète",
"code": {
"@type": "MedicalCode",
"code": "D003824",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.200.205"
}
},
"hasPart": [
{
"@type": "MedicalWebPage",
"name": "Prothèse dentaire complète immédiate",
"alternateName": "Denture, Complete, Immediate",
"url": "https://questionsmedicales.fr/mesh/D003825",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse dentaire complète immédiate",
"code": {
"@type": "MedicalCode",
"code": "D003825",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.200.205.205"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Prothèse dentaire complète inférieure",
"alternateName": "Denture, Complete, Lower",
"url": "https://questionsmedicales.fr/mesh/D003826",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse dentaire complète inférieure",
"code": {
"@type": "MedicalCode",
"code": "D003826",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.200.205.210"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Prothèse dentaire complète supérieure",
"alternateName": "Denture, Complete, Upper",
"url": "https://questionsmedicales.fr/mesh/D003827",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse dentaire complète supérieure",
"code": {
"@type": "MedicalCode",
"code": "D003827",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.200.205.215"
}
}
}
]
},
{
"@type": "MedicalWebPage",
"name": "Prothèse dentaire complète immédiate",
"alternateName": "Denture, Complete, Immediate",
"url": "https://questionsmedicales.fr/mesh/D003825",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse dentaire complète immédiate",
"code": {
"@type": "MedicalCode",
"code": "D003825",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.200.205.205"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Prothèse dentaire complète inférieure",
"alternateName": "Denture, Complete, Lower",
"url": "https://questionsmedicales.fr/mesh/D003826",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse dentaire complète inférieure",
"code": {
"@type": "MedicalCode",
"code": "D003826",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.200.205.210"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Prothèse dentaire complète supérieure",
"alternateName": "Denture, Complete, Upper",
"url": "https://questionsmedicales.fr/mesh/D003827",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse dentaire complète supérieure",
"code": {
"@type": "MedicalCode",
"code": "D003827",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.200.205.215"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Vernis protecteurs d'appareil de prothèse dentaire",
"alternateName": "Denture Liners",
"url": "https://questionsmedicales.fr/mesh/D003822",
"about": {
"@type": "MedicalCondition",
"name": "Vernis protecteurs d'appareil de prothèse dentaire",
"code": {
"@type": "MedicalCode",
"code": "D003822",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.200.210"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Overdenture",
"alternateName": "Denture, Overlay",
"url": "https://questionsmedicales.fr/mesh/D003828",
"about": {
"@type": "MedicalCondition",
"name": "Overdenture",
"code": {
"@type": "MedicalCode",
"code": "D003828",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.200.215"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Prothèse partielle conjointe",
"alternateName": "Denture, Partial",
"url": "https://questionsmedicales.fr/mesh/D003829",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse partielle conjointe",
"code": {
"@type": "MedicalCode",
"code": "D003829",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.200.220"
}
},
"hasPart": [
{
"@type": "MedicalWebPage",
"name": "Prothèse partielle fixe",
"alternateName": "Denture, Partial, Fixed",
"url": "https://questionsmedicales.fr/mesh/D003830",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse partielle fixe",
"code": {
"@type": "MedicalCode",
"code": "D003830",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.200.220.220"
}
},
"hasPart": [
{
"@type": "MedicalWebPage",
"name": "Prothèse dentaire partielle fixe à liaison résine",
"alternateName": "Denture, Partial, Fixed, Resin-Bonded",
"url": "https://questionsmedicales.fr/mesh/D016379",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse dentaire partielle fixe à liaison résine",
"code": {
"@type": "MedicalCode",
"code": "D016379",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.200.220.220.220"
}
}
}
]
},
{
"@type": "MedicalWebPage",
"name": "Prothèse dentaire partielle fixe à liaison résine",
"alternateName": "Denture, Partial, Fixed, Resin-Bonded",
"url": "https://questionsmedicales.fr/mesh/D016379",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse dentaire partielle fixe à liaison résine",
"code": {
"@type": "MedicalCode",
"code": "D016379",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.200.220.220.220"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Prothèse dentaire partielle immédiate",
"alternateName": "Denture, Partial, Immediate",
"url": "https://questionsmedicales.fr/mesh/D003831",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse dentaire partielle immédiate",
"code": {
"@type": "MedicalCode",
"code": "D003831",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.200.220.225"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Prothèse dentaire partielle amovible",
"alternateName": "Denture, Partial, Removable",
"url": "https://questionsmedicales.fr/mesh/D003832",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse dentaire partielle amovible",
"code": {
"@type": "MedicalCode",
"code": "D003832",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.200.220.230"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Prothèse dentaire partielle provisoire",
"alternateName": "Denture, Partial, Temporary",
"url": "https://questionsmedicales.fr/mesh/D003833",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse dentaire partielle provisoire",
"code": {
"@type": "MedicalCode",
"code": "D003833",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.200.220.235"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Attachement de précision",
"alternateName": "Denture Precision Attachment",
"url": "https://questionsmedicales.fr/mesh/D003834",
"about": {
"@type": "MedicalCondition",
"name": "Attachement de précision",
"code": {
"@type": "MedicalCode",
"code": "D003834",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.200.220.245"
}
}
}
]
},
{
"@type": "MedicalWebPage",
"name": "Prothèse partielle fixe",
"alternateName": "Denture, Partial, Fixed",
"url": "https://questionsmedicales.fr/mesh/D003830",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse partielle fixe",
"code": {
"@type": "MedicalCode",
"code": "D003830",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.200.220.220"
}
},
"hasPart": [
{
"@type": "MedicalWebPage",
"name": "Prothèse dentaire partielle fixe à liaison résine",
"alternateName": "Denture, Partial, Fixed, Resin-Bonded",
"url": "https://questionsmedicales.fr/mesh/D016379",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse dentaire partielle fixe à liaison résine",
"code": {
"@type": "MedicalCode",
"code": "D016379",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.200.220.220.220"
}
}
}
]
},
{
"@type": "MedicalWebPage",
"name": "Prothèse dentaire partielle fixe à liaison résine",
"alternateName": "Denture, Partial, Fixed, Resin-Bonded",
"url": "https://questionsmedicales.fr/mesh/D016379",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse dentaire partielle fixe à liaison résine",
"code": {
"@type": "MedicalCode",
"code": "D016379",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.200.220.220.220"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Prothèse dentaire partielle immédiate",
"alternateName": "Denture, Partial, Immediate",
"url": "https://questionsmedicales.fr/mesh/D003831",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse dentaire partielle immédiate",
"code": {
"@type": "MedicalCode",
"code": "D003831",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.200.220.225"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Prothèse dentaire partielle amovible",
"alternateName": "Denture, Partial, Removable",
"url": "https://questionsmedicales.fr/mesh/D003832",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse dentaire partielle amovible",
"code": {
"@type": "MedicalCode",
"code": "D003832",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.200.220.230"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Prothèse dentaire partielle provisoire",
"alternateName": "Denture, Partial, Temporary",
"url": "https://questionsmedicales.fr/mesh/D003833",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse dentaire partielle provisoire",
"code": {
"@type": "MedicalCode",
"code": "D003833",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.200.220.235"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Attachement de précision",
"alternateName": "Denture Precision Attachment",
"url": "https://questionsmedicales.fr/mesh/D003834",
"about": {
"@type": "MedicalCondition",
"name": "Attachement de précision",
"code": {
"@type": "MedicalCode",
"code": "D003834",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.200.220.245"
}
}
}
]
},
{
"@type": "MedicalWebPage",
"name": "Bases d'appareil de prothèse dentaire",
"alternateName": "Denture Bases",
"url": "https://questionsmedicales.fr/mesh/D003819",
"about": {
"@type": "MedicalCondition",
"name": "Bases d'appareil de prothèse dentaire",
"code": {
"@type": "MedicalCode",
"code": "D003819",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.200.200"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Prothèse dentaire complète",
"alternateName": "Denture, Complete",
"url": "https://questionsmedicales.fr/mesh/D003824",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse dentaire complète",
"code": {
"@type": "MedicalCode",
"code": "D003824",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.200.205"
}
},
"hasPart": [
{
"@type": "MedicalWebPage",
"name": "Prothèse dentaire complète immédiate",
"alternateName": "Denture, Complete, Immediate",
"url": "https://questionsmedicales.fr/mesh/D003825",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse dentaire complète immédiate",
"code": {
"@type": "MedicalCode",
"code": "D003825",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.200.205.205"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Prothèse dentaire complète inférieure",
"alternateName": "Denture, Complete, Lower",
"url": "https://questionsmedicales.fr/mesh/D003826",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse dentaire complète inférieure",
"code": {
"@type": "MedicalCode",
"code": "D003826",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.200.205.210"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Prothèse dentaire complète supérieure",
"alternateName": "Denture, Complete, Upper",
"url": "https://questionsmedicales.fr/mesh/D003827",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse dentaire complète supérieure",
"code": {
"@type": "MedicalCode",
"code": "D003827",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.200.205.215"
}
}
}
]
},
{
"@type": "MedicalWebPage",
"name": "Prothèse dentaire complète immédiate",
"alternateName": "Denture, Complete, Immediate",
"url": "https://questionsmedicales.fr/mesh/D003825",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse dentaire complète immédiate",
"code": {
"@type": "MedicalCode",
"code": "D003825",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.200.205.205"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Prothèse dentaire complète inférieure",
"alternateName": "Denture, Complete, Lower",
"url": "https://questionsmedicales.fr/mesh/D003826",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse dentaire complète inférieure",
"code": {
"@type": "MedicalCode",
"code": "D003826",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.200.205.210"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Prothèse dentaire complète supérieure",
"alternateName": "Denture, Complete, Upper",
"url": "https://questionsmedicales.fr/mesh/D003827",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse dentaire complète supérieure",
"code": {
"@type": "MedicalCode",
"code": "D003827",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.200.205.215"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Vernis protecteurs d'appareil de prothèse dentaire",
"alternateName": "Denture Liners",
"url": "https://questionsmedicales.fr/mesh/D003822",
"about": {
"@type": "MedicalCondition",
"name": "Vernis protecteurs d'appareil de prothèse dentaire",
"code": {
"@type": "MedicalCode",
"code": "D003822",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.200.210"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Overdenture",
"alternateName": "Denture, Overlay",
"url": "https://questionsmedicales.fr/mesh/D003828",
"about": {
"@type": "MedicalCondition",
"name": "Overdenture",
"code": {
"@type": "MedicalCode",
"code": "D003828",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.200.215"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Prothèse partielle conjointe",
"alternateName": "Denture, Partial",
"url": "https://questionsmedicales.fr/mesh/D003829",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse partielle conjointe",
"code": {
"@type": "MedicalCode",
"code": "D003829",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.200.220"
}
},
"hasPart": [
{
"@type": "MedicalWebPage",
"name": "Prothèse partielle fixe",
"alternateName": "Denture, Partial, Fixed",
"url": "https://questionsmedicales.fr/mesh/D003830",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse partielle fixe",
"code": {
"@type": "MedicalCode",
"code": "D003830",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.200.220.220"
}
},
"hasPart": [
{
"@type": "MedicalWebPage",
"name": "Prothèse dentaire partielle fixe à liaison résine",
"alternateName": "Denture, Partial, Fixed, Resin-Bonded",
"url": "https://questionsmedicales.fr/mesh/D016379",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse dentaire partielle fixe à liaison résine",
"code": {
"@type": "MedicalCode",
"code": "D016379",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.200.220.220.220"
}
}
}
]
},
{
"@type": "MedicalWebPage",
"name": "Prothèse dentaire partielle fixe à liaison résine",
"alternateName": "Denture, Partial, Fixed, Resin-Bonded",
"url": "https://questionsmedicales.fr/mesh/D016379",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse dentaire partielle fixe à liaison résine",
"code": {
"@type": "MedicalCode",
"code": "D016379",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.200.220.220.220"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Prothèse dentaire partielle immédiate",
"alternateName": "Denture, Partial, Immediate",
"url": "https://questionsmedicales.fr/mesh/D003831",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse dentaire partielle immédiate",
"code": {
"@type": "MedicalCode",
"code": "D003831",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.200.220.225"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Prothèse dentaire partielle amovible",
"alternateName": "Denture, Partial, Removable",
"url": "https://questionsmedicales.fr/mesh/D003832",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse dentaire partielle amovible",
"code": {
"@type": "MedicalCode",
"code": "D003832",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.200.220.230"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Prothèse dentaire partielle provisoire",
"alternateName": "Denture, Partial, Temporary",
"url": "https://questionsmedicales.fr/mesh/D003833",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse dentaire partielle provisoire",
"code": {
"@type": "MedicalCode",
"code": "D003833",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.200.220.235"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Attachement de précision",
"alternateName": "Denture Precision Attachment",
"url": "https://questionsmedicales.fr/mesh/D003834",
"about": {
"@type": "MedicalCondition",
"name": "Attachement de précision",
"code": {
"@type": "MedicalCode",
"code": "D003834",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.200.220.245"
}
}
}
]
},
{
"@type": "MedicalWebPage",
"name": "Prothèse partielle fixe",
"alternateName": "Denture, Partial, Fixed",
"url": "https://questionsmedicales.fr/mesh/D003830",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse partielle fixe",
"code": {
"@type": "MedicalCode",
"code": "D003830",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.200.220.220"
}
},
"hasPart": [
{
"@type": "MedicalWebPage",
"name": "Prothèse dentaire partielle fixe à liaison résine",
"alternateName": "Denture, Partial, Fixed, Resin-Bonded",
"url": "https://questionsmedicales.fr/mesh/D016379",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse dentaire partielle fixe à liaison résine",
"code": {
"@type": "MedicalCode",
"code": "D016379",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.200.220.220.220"
}
}
}
]
},
{
"@type": "MedicalWebPage",
"name": "Prothèse dentaire partielle fixe à liaison résine",
"alternateName": "Denture, Partial, Fixed, Resin-Bonded",
"url": "https://questionsmedicales.fr/mesh/D016379",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse dentaire partielle fixe à liaison résine",
"code": {
"@type": "MedicalCode",
"code": "D016379",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.200.220.220.220"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Prothèse dentaire partielle immédiate",
"alternateName": "Denture, Partial, Immediate",
"url": "https://questionsmedicales.fr/mesh/D003831",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse dentaire partielle immédiate",
"code": {
"@type": "MedicalCode",
"code": "D003831",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.200.220.225"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Prothèse dentaire partielle amovible",
"alternateName": "Denture, Partial, Removable",
"url": "https://questionsmedicales.fr/mesh/D003832",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse dentaire partielle amovible",
"code": {
"@type": "MedicalCode",
"code": "D003832",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.200.220.230"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Prothèse dentaire partielle provisoire",
"alternateName": "Denture, Partial, Temporary",
"url": "https://questionsmedicales.fr/mesh/D003833",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse dentaire partielle provisoire",
"code": {
"@type": "MedicalCode",
"code": "D003833",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.200.220.235"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Attachement de précision",
"alternateName": "Denture Precision Attachment",
"url": "https://questionsmedicales.fr/mesh/D003834",
"about": {
"@type": "MedicalCondition",
"name": "Attachement de précision",
"code": {
"@type": "MedicalCode",
"code": "D003834",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.200.220.245"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Obturateurs palatins",
"alternateName": "Palatal Obturators",
"url": "https://questionsmedicales.fr/mesh/D010158",
"about": {
"@type": "MedicalCondition",
"name": "Obturateurs palatins",
"code": {
"@type": "MedicalCode",
"code": "D010158",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.600"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Prothèse parodontale",
"alternateName": "Periodontal Prosthesis",
"url": "https://questionsmedicales.fr/mesh/D010515",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse parodontale",
"code": {
"@type": "MedicalCode",
"code": "D010515",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.610"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Dent artificielle",
"alternateName": "Tooth, Artificial",
"url": "https://questionsmedicales.fr/mesh/D014093",
"about": {
"@type": "MedicalCondition",
"name": "Dent artificielle",
"code": {
"@type": "MedicalCode",
"code": "D014093",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.190.800"
}
}
}
]
},
{
"@type": "MedicalWebPage",
"name": "Électrodes implantées",
"alternateName": "Electrodes, Implanted",
"url": "https://questionsmedicales.fr/mesh/D004567",
"about": {
"@type": "MedicalCondition",
"name": "Électrodes implantées",
"code": {
"@type": "MedicalCode",
"code": "D004567",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.202"
}
},
"hasPart": [
{
"@type": "MedicalWebPage",
"name": "Défibrillateurs implantables",
"alternateName": "Defibrillators, Implantable",
"url": "https://questionsmedicales.fr/mesh/D017147",
"about": {
"@type": "MedicalCondition",
"name": "Défibrillateurs implantables",
"code": {
"@type": "MedicalCode",
"code": "D017147",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.202.175"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Neurostimulateurs implantables",
"alternateName": "Implantable Neurostimulators",
"url": "https://questionsmedicales.fr/mesh/D058542",
"about": {
"@type": "MedicalCondition",
"name": "Neurostimulateurs implantables",
"code": {
"@type": "MedicalCode",
"code": "D058542",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.202.381"
}
},
"hasPart": [
{
"@type": "MedicalWebPage",
"name": "Neuroprothèses",
"alternateName": "Neural Prostheses",
"url": "https://questionsmedicales.fr/mesh/D058117",
"about": {
"@type": "MedicalCondition",
"name": "Neuroprothèses",
"code": {
"@type": "MedicalCode",
"code": "D058117",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.202.381.500"
}
}
}
]
},
{
"@type": "MedicalWebPage",
"name": "Neuroprothèses",
"alternateName": "Neural Prostheses",
"url": "https://questionsmedicales.fr/mesh/D058117",
"about": {
"@type": "MedicalCondition",
"name": "Neuroprothèses",
"code": {
"@type": "MedicalCode",
"code": "D058117",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.202.381.500"
}
}
}
]
},
{
"@type": "MedicalWebPage",
"name": "Dispositifs de protection embolique",
"alternateName": "Embolic Protection Devices",
"url": "https://questionsmedicales.fr/mesh/D057505",
"about": {
"@type": "MedicalCondition",
"name": "Dispositifs de protection embolique",
"code": {
"@type": "MedicalCode",
"code": "D057505",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.207"
}
},
"hasPart": [
{
"@type": "MedicalWebPage",
"name": "Filtres caves",
"alternateName": "Vena Cava Filters",
"url": "https://questionsmedicales.fr/mesh/D016306",
"about": {
"@type": "MedicalCondition",
"name": "Filtres caves",
"code": {
"@type": "MedicalCode",
"code": "D016306",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.207.500"
}
}
}
]
},
{
"@type": "MedicalWebPage",
"name": "Oeil artificiel",
"alternateName": "Eye, Artificial",
"url": "https://questionsmedicales.fr/mesh/D005137",
"about": {
"@type": "MedicalCondition",
"name": "Oeil artificiel",
"code": {
"@type": "MedicalCode",
"code": "D005137",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.225"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Implants de drainage du glaucome",
"alternateName": "Glaucoma Drainage Implants",
"url": "https://questionsmedicales.fr/mesh/D020327",
"about": {
"@type": "MedicalCondition",
"name": "Implants de drainage du glaucome",
"code": {
"@type": "MedicalCode",
"code": "D020327",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.250"
}
},
"hasPart": [
{
"@type": "MedicalWebPage",
"name": "Implant de Molténo",
"alternateName": "Molteno Implants",
"url": "https://questionsmedicales.fr/mesh/D018465",
"about": {
"@type": "MedicalCondition",
"name": "Implant de Molténo",
"code": {
"@type": "MedicalCode",
"code": "D018465",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.250.500"
}
}
}
]
},
{
"@type": "MedicalWebPage",
"name": "Prothèse valvulaire cardiaque",
"alternateName": "Heart Valve Prosthesis",
"url": "https://questionsmedicales.fr/mesh/D006350",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse valvulaire cardiaque",
"code": {
"@type": "MedicalCode",
"code": "D006350",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.310"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Implants expérimentaux",
"alternateName": "Implants, Experimental",
"url": "https://questionsmedicales.fr/mesh/D020007",
"about": {
"@type": "MedicalCondition",
"name": "Implants expérimentaux",
"code": {
"@type": "MedicalCode",
"code": "D020007",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.340"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Prothèse articulaire",
"alternateName": "Joint Prosthesis",
"url": "https://questionsmedicales.fr/mesh/D007595",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse articulaire",
"code": {
"@type": "MedicalCode",
"code": "D007595",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.400"
}
},
"hasPart": [
{
"@type": "MedicalWebPage",
"name": "Prothèse de coude",
"alternateName": "Elbow Prosthesis",
"url": "https://questionsmedicales.fr/mesh/D058569",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse de coude",
"code": {
"@type": "MedicalCode",
"code": "D058569",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.400.300"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Prothèse de hanche",
"alternateName": "Hip Prosthesis",
"url": "https://questionsmedicales.fr/mesh/D006622",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse de hanche",
"code": {
"@type": "MedicalCode",
"code": "D006622",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.400.400"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Prothèse de genou",
"alternateName": "Knee Prosthesis",
"url": "https://questionsmedicales.fr/mesh/D007720",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse de genou",
"code": {
"@type": "MedicalCode",
"code": "D007720",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.400.410"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Prothèses articulaires métal-métal",
"alternateName": "Metal-on-Metal Joint Prostheses",
"url": "https://questionsmedicales.fr/mesh/D061825",
"about": {
"@type": "MedicalCondition",
"name": "Prothèses articulaires métal-métal",
"code": {
"@type": "MedicalCode",
"code": "D061825",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.400.705"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Prothèse d'épaule",
"alternateName": "Shoulder Prosthesis",
"url": "https://questionsmedicales.fr/mesh/D000072227",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse d'épaule",
"code": {
"@type": "MedicalCode",
"code": "D000072227",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.400.852"
}
}
}
]
},
{
"@type": "MedicalWebPage",
"name": "Lentilles intraoculaires",
"alternateName": "Lenses, Intraocular",
"url": "https://questionsmedicales.fr/mesh/D007910",
"about": {
"@type": "MedicalCondition",
"name": "Lentilles intraoculaires",
"code": {
"@type": "MedicalCode",
"code": "D007910",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.460"
}
},
"hasPart": [
{
"@type": "MedicalWebPage",
"name": "Lentilles intraoculaires multifocales",
"alternateName": "Multifocal Intraocular Lenses",
"url": "https://questionsmedicales.fr/mesh/D000075542",
"about": {
"@type": "MedicalCondition",
"name": "Lentilles intraoculaires multifocales",
"code": {
"@type": "MedicalCode",
"code": "D000075542",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.460.500"
}
}
}
]
},
{
"@type": "MedicalWebPage",
"name": "Prothèse maxillofaciale",
"alternateName": "Maxillofacial Prosthesis",
"url": "https://questionsmedicales.fr/mesh/D008447",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse maxillofaciale",
"code": {
"@type": "MedicalCode",
"code": "D008447",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.510"
}
},
"hasPart": [
{
"@type": "MedicalWebPage",
"name": "Prothèse mandibulaire",
"alternateName": "Mandibular Prosthesis",
"url": "https://questionsmedicales.fr/mesh/D008341",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse mandibulaire",
"code": {
"@type": "MedicalCode",
"code": "D008341",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.510.500"
}
}
}
]
},
{
"@type": "MedicalWebPage",
"name": "Implants orbitaires",
"alternateName": "Orbital Implants",
"url": "https://questionsmedicales.fr/mesh/D020273",
"about": {
"@type": "MedicalCondition",
"name": "Implants orbitaires",
"code": {
"@type": "MedicalCode",
"code": "D020273",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.540"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Prothèse ossiculaire",
"alternateName": "Ossicular Prosthesis",
"url": "https://questionsmedicales.fr/mesh/D009998",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse ossiculaire",
"code": {
"@type": "MedicalCode",
"code": "D009998",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.550"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Prothèse pénienne",
"alternateName": "Penile Prosthesis",
"url": "https://questionsmedicales.fr/mesh/D015917",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse pénienne",
"code": {
"@type": "MedicalCode",
"code": "D015917",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.610"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Conception de prothèse",
"alternateName": "Prosthesis Design",
"url": "https://questionsmedicales.fr/mesh/D011474",
"about": {
"@type": "MedicalCondition",
"name": "Conception de prothèse",
"code": {
"@type": "MedicalCode",
"code": "D011474",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.680"
}
},
"hasPart": [
{
"@type": "MedicalWebPage",
"name": "Coloration de prothèse",
"alternateName": "Prosthesis Coloring",
"url": "https://questionsmedicales.fr/mesh/D017797",
"about": {
"@type": "MedicalCondition",
"name": "Coloration de prothèse",
"code": {
"@type": "MedicalCode",
"code": "D017797",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.680.550"
}
}
}
]
},
{
"@type": "MedicalWebPage",
"name": "Bouchons méatiques",
"alternateName": "Punctal Plugs",
"url": "https://questionsmedicales.fr/mesh/D000070635",
"about": {
"@type": "MedicalCondition",
"name": "Bouchons méatiques",
"code": {
"@type": "MedicalCode",
"code": "D000070635",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.698"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Dispositif d'occlusion septale",
"alternateName": "Septal Occluder Device",
"url": "https://questionsmedicales.fr/mesh/D055989",
"about": {
"@type": "MedicalCondition",
"name": "Dispositif d'occlusion septale",
"code": {
"@type": "MedicalCode",
"code": "D055989",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.715"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Endoprothèses",
"alternateName": "Stents",
"url": "https://questionsmedicales.fr/mesh/D015607",
"about": {
"@type": "MedicalCondition",
"name": "Endoprothèses",
"code": {
"@type": "MedicalCode",
"code": "D015607",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.750"
}
},
"hasPart": [
{
"@type": "MedicalWebPage",
"name": "Endoprothèses à élution de substances",
"alternateName": "Drug-Eluting Stents",
"url": "https://questionsmedicales.fr/mesh/D054855",
"about": {
"@type": "MedicalCondition",
"name": "Endoprothèses à élution de substances",
"code": {
"@type": "MedicalCode",
"code": "D054855",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.750.500"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Endoprothèses métalliques auto-expansibles",
"alternateName": "Self Expandable Metallic Stents",
"url": "https://questionsmedicales.fr/mesh/D000069322",
"about": {
"@type": "MedicalCondition",
"name": "Endoprothèses métalliques auto-expansibles",
"code": {
"@type": "MedicalCode",
"code": "D000069322",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.750.750"
}
}
}
]
},
{
"@type": "MedicalWebPage",
"name": "Bandelettes sous-urétrales",
"alternateName": "Suburethral Slings",
"url": "https://questionsmedicales.fr/mesh/D053825",
"about": {
"@type": "MedicalCondition",
"name": "Bandelettes sous-urétrales",
"code": {
"@type": "MedicalCode",
"code": "D053825",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.752"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Structures d'échafaudage tissulaires",
"alternateName": "Tissue Scaffolds",
"url": "https://questionsmedicales.fr/mesh/D054457",
"about": {
"@type": "MedicalCondition",
"name": "Structures d'échafaudage tissulaires",
"code": {
"@type": "MedicalCode",
"code": "D054457",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.825"
}
}
},
{
"@type": "MedicalWebPage",
"name": "Prothèse visuelle",
"alternateName": "Visual Prosthesis",
"url": "https://questionsmedicales.fr/mesh/D057488",
"about": {
"@type": "MedicalCondition",
"name": "Prothèse visuelle",
"code": {
"@type": "MedicalCode",
"code": "D057488",
"codingSystem": "MeSH"
},
"identifier": {
"@type": "PropertyValue",
"propertyID": "MeSH Tree",
"value": "E07.695.950"
}
}
}
],
"about": {
"@type": "MedicalCondition",
"name": "Prothèses et implants",
"alternateName": "Prostheses and Implants",
"code": {
"@type": "MedicalCode",
"code": "D019736",
"codingSystem": "MeSH"
}
},
"author": [
{
"@type": "Person",
"name": "Estevam A Bonfante",
"url": "https://questionsmedicales.fr/author/Estevam%20A%20Bonfante",
"affiliation": {
"@type": "Organization",
"name": "Department of Prosthodontics and Periodontology, University of São Paulo, Bauru School of Dentistry, Bauru, SP, Brazil."
}
},
{
"@type": "Person",
"name": "Konstantinos Chochlidakis",
"url": "https://questionsmedicales.fr/author/Konstantinos%20Chochlidakis",
"affiliation": {
"@type": "Organization",
"name": "Department of Prosthodontics, Eastman Institute for Oral Health, University of Rochester, NY."
}
},
{
"@type": "Person",
"name": "Panos Papaspyridakos",
"url": "https://questionsmedicales.fr/author/Panos%20Papaspyridakos",
"affiliation": {
"@type": "Organization",
"name": "Department of Prosthodontics, Eastman Institute for Oral Health, University of Rochester, NY."
}
},
{
"@type": "Person",
"name": "Joseph Carpentieri",
"url": "https://questionsmedicales.fr/author/Joseph%20Carpentieri",
"affiliation": {
"@type": "Organization",
"name": "Assistant Clinical Professor, Department of Prosthodontics, College of Dental Medicine, Columbia University, New York, New York; Director of Clinical Education, Dental365™, New Hyde Park, New York; Private Practice, Surgical Implantology and Prosthodontics, White Plains, New York."
}
},
{
"@type": "Person",
"name": "Gary Greenstein",
"url": "https://questionsmedicales.fr/author/Gary%20Greenstein",
"affiliation": {
"@type": "Organization",
"name": "Clinical Professor, Department of Periodontics, College of Dental Medicine, Columbia University, New York, New York; Private Practice, Surgical Implantology and Periodontics, Freehold, New Jersey."
}
}
],
"citation": [
{
"@type": "ScholarlyArticle",
"name": "Comparative study on three-dimensional versus two-dimensional imaging using a computer-assisted surgery system for preoperative planning in pediatric middle hepatic tumors.",
"datePublished": "2024-08-21",
"url": "https://questionsmedicales.fr/article/39169378",
"identifier": {
"@type": "PropertyValue",
"propertyID": "DOI",
"value": "10.1186/s12893-024-02531-y"
}
},
{
"@type": "ScholarlyArticle",
"name": "Open-sleeve templates for computer-assisted implant surgery at healed or extraction sockets: An in vitro comparison to closed-sleeve guided system and free-hand approach.",
"datePublished": "2022-05-26",
"url": "https://questionsmedicales.fr/article/35578783",
"identifier": {
"@type": "PropertyValue",
"propertyID": "DOI",
"value": "10.1111/clr.13957"
}
},
{
"@type": "ScholarlyArticle",
"name": "Guided innovations: Robot-assisted dental implant surgery.",
"datePublished": "2022-05-26",
"url": "https://questionsmedicales.fr/article/35643826",
"identifier": {
"@type": "PropertyValue",
"propertyID": "DOI",
"value": "10.1016/j.prosdent.2022.03.029"
}
},
{
"@type": "ScholarlyArticle",
"name": "Computer-assisted bone augmentation, implant planning and placement: An in vitro investigation.",
"datePublished": "2023-05-30",
"url": "https://questionsmedicales.fr/article/37248956",
"identifier": {
"@type": "PropertyValue",
"propertyID": "DOI",
"value": "10.1111/clr.14098"
}
},
{
"@type": "ScholarlyArticle",
"name": "Ultrasound-Based Registration for the Computer-Assisted Navigated Percutaneous Scaphoid Fixation.",
"datePublished": "2023-08-29",
"url": "https://questionsmedicales.fr/article/37399161",
"identifier": {
"@type": "PropertyValue",
"propertyID": "DOI",
"value": "10.1109/TUFFC.2023.3291387"
}
}
],
"breadcrumb": {
"@type": "BreadcrumbList",
"itemListElement": [
{
"@type": "ListItem",
"position": 1,
"name": "questionsmedicales.fr",
"item": "https://questionsmedicales.fr"
},
{
"@type": "ListItem",
"position": 2,
"name": "Équipement et fournitures",
"item": "https://questionsmedicales.fr/mesh/D004864"
},
{
"@type": "ListItem",
"position": 3,
"name": "Prothèses et implants",
"item": "https://questionsmedicales.fr/mesh/D019736"
}
]
}
},
{
"@type": "MedicalWebPage",
"name": "Article complet : Prothèses et implants - Questions et réponses",
"headline": "Questions et réponses médicales fréquentes sur Prothèses et implants",
"description": "Une compilation de questions et réponses structurées, validées par des experts médicaux.",
"datePublished": "2025-05-08",
"inLanguage": "fr",
"hasPart": [
{
"@type": "MedicalWebPage",
"name": "Diagnostic",
"headline": "Diagnostic sur Prothèses et implants",
"description": "Comment diagnostiquer un besoin de prothèse ?\nQuels tests sont utilisés pour évaluer les implants ?\nQuels signes indiquent un problème avec une prothèse ?\nQuand consulter un médecin après une implantation ?\nQuels symptômes nécessitent un diagnostic urgent ?",
"url": "https://questionsmedicales.fr/mesh/D019736?mesh_terms=Surgery,+Computer-Assisted&page=3#section-diagnostic"
},
{
"@type": "MedicalWebPage",
"name": "Symptômes",
"headline": "Symptômes sur Prothèses et implants",
"description": "Quels symptômes peuvent survenir après une chirurgie de prothèse ?\nComment reconnaître une infection d'implant ?\nQuels signes indiquent un rejet de prothèse ?\nLes implants peuvent-ils causer des allergies ?\nQuels symptômes sont liés à une défaillance d'implant ?",
"url": "https://questionsmedicales.fr/mesh/D019736?mesh_terms=Surgery,+Computer-Assisted&page=3#section-symptômes"
},
{
"@type": "MedicalWebPage",
"name": "Prévention",
"headline": "Prévention sur Prothèses et implants",
"description": "Comment prévenir les infections après une chirurgie d'implant ?\nQuelles mesures prendre pour éviter le rejet d'implant ?\nComment réduire le risque de complications avec des prothèses ?\nQuels conseils pour une bonne récupération après une prothèse ?\nLes habitudes de vie influencent-elles le succès des implants ?",
"url": "https://questionsmedicales.fr/mesh/D019736?mesh_terms=Surgery,+Computer-Assisted&page=3#section-prévention"
},
{
"@type": "MedicalWebPage",
"name": "Traitements",
"headline": "Traitements sur Prothèses et implants",
"description": "Quels traitements sont disponibles pour les complications d'implants ?\nComment gérer la douleur après une chirurgie de prothèse ?\nQuand envisager le remplacement d'une prothèse ?\nQuels soins sont nécessaires après la pose d'un implant ?\nLes prothèses nécessitent-elles un entretien ?",
"url": "https://questionsmedicales.fr/mesh/D019736?mesh_terms=Surgery,+Computer-Assisted&page=3#section-traitements"
},
{
"@type": "MedicalWebPage",
"name": "Complications",
"headline": "Complications sur Prothèses et implants",
"description": "Quelles sont les complications possibles des prothèses ?\nComment gérer une infection d'implant ?\nQuels sont les signes d'une défaillance d'implant ?\nLes prothèses peuvent-elles provoquer des douleurs chroniques ?\nQuelles sont les conséquences d'un rejet d'implant ?",
"url": "https://questionsmedicales.fr/mesh/D019736?mesh_terms=Surgery,+Computer-Assisted&page=3#section-complications"
},
{
"@type": "MedicalWebPage",
"name": "Facteurs de risque",
"headline": "Facteurs de risque sur Prothèses et implants",
"description": "Quels facteurs augmentent le risque d'infection après une chirurgie ?\nL'âge influence-t-il le succès des implants ?\nQuels antécédents médicaux sont des facteurs de risque ?\nLe mode de vie affecte-t-il le succès des prothèses ?\nLes allergies aux matériaux influencent-elles le choix d'implant ?",
"url": "https://questionsmedicales.fr/mesh/D019736?mesh_terms=Surgery,+Computer-Assisted&page=3#section-facteurs de risque"
}
]
},
{
"@type": "FAQPage",
"mainEntity": [
{
"@type": "Question",
"name": "Comment diagnostiquer un besoin de prothèse ?",
"position": 1,
"acceptedAnswer": {
"@type": "Answer",
"text": "Un examen clinique et des imageries médicales déterminent la nécessité d'une prothèse."
}
},
{
"@type": "Question",
"name": "Quels tests sont utilisés pour évaluer les implants ?",
"position": 2,
"acceptedAnswer": {
"@type": "Answer",
"text": "Des radiographies et IRM sont souvent utilisés pour évaluer la position des implants."
}
},
{
"@type": "Question",
"name": "Quels signes indiquent un problème avec une prothèse ?",
"position": 3,
"acceptedAnswer": {
"@type": "Answer",
"text": "Douleur persistante, gonflement ou mobilité anormale peuvent indiquer un problème."
}
},
{
"@type": "Question",
"name": "Quand consulter un médecin après une implantation ?",
"position": 4,
"acceptedAnswer": {
"@type": "Answer",
"text": "Consultez si vous ressentez des douleurs intenses ou des signes d'infection."
}
},
{
"@type": "Question",
"name": "Quels symptômes nécessitent un diagnostic urgent ?",
"position": 5,
"acceptedAnswer": {
"@type": "Answer",
"text": "Fièvre, rougeur ou écoulement autour de l'implant nécessitent une évaluation rapide."
}
},
{
"@type": "Question",
"name": "Quels symptômes peuvent survenir après une chirurgie de prothèse ?",
"position": 6,
"acceptedAnswer": {
"@type": "Answer",
"text": "Douleur, gonflement et raideur sont courants après une chirurgie de prothèse."
}
},
{
"@type": "Question",
"name": "Comment reconnaître une infection d'implant ?",
"position": 7,
"acceptedAnswer": {
"@type": "Answer",
"text": "Rougeur, chaleur, douleur et écoulement autour de l'implant signalent une infection."
}
},
{
"@type": "Question",
"name": "Quels signes indiquent un rejet de prothèse ?",
"position": 8,
"acceptedAnswer": {
"@type": "Answer",
"text": "Douleur accrue, gonflement et mobilité anormale peuvent indiquer un rejet."
}
},
{
"@type": "Question",
"name": "Les implants peuvent-ils causer des allergies ?",
"position": 9,
"acceptedAnswer": {
"@type": "Answer",
"text": "Oui, certains matériaux d'implant peuvent provoquer des réactions allergiques."
}
},
{
"@type": "Question",
"name": "Quels symptômes sont liés à une défaillance d'implant ?",
"position": 10,
"acceptedAnswer": {
"@type": "Answer",
"text": "Douleur persistante, instabilité ou bruit anormal peuvent signaler une défaillance."
}
},
{
"@type": "Question",
"name": "Comment prévenir les infections après une chirurgie d'implant ?",
"position": 11,
"acceptedAnswer": {
"@type": "Answer",
"text": "Suivre les instructions post-opératoires et prendre des antibiotiques préventifs aide."
}
},
{
"@type": "Question",
"name": "Quelles mesures prendre pour éviter le rejet d'implant ?",
"position": 12,
"acceptedAnswer": {
"@type": "Answer",
"text": "Choisir des matériaux biocompatibles et suivre les conseils médicaux réduit le risque."
}
},
{
"@type": "Question",
"name": "Comment réduire le risque de complications avec des prothèses ?",
"position": 13,
"acceptedAnswer": {
"@type": "Answer",
"text": "Un suivi régulier et une bonne hygiène sont cruciaux pour prévenir les complications."
}
},
{
"@type": "Question",
"name": "Quels conseils pour une bonne récupération après une prothèse ?",
"position": 14,
"acceptedAnswer": {
"@type": "Answer",
"text": "Respecter les recommandations médicales et pratiquer des exercices adaptés favorise la récupération."
}
},
{
"@type": "Question",
"name": "Les habitudes de vie influencent-elles le succès des implants ?",
"position": 15,
"acceptedAnswer": {
"@type": "Answer",
"text": "Oui, une alimentation saine et l'évitement du tabac améliorent le succès des implants."
}
},
{
"@type": "Question",
"name": "Quels traitements sont disponibles pour les complications d'implants ?",
"position": 16,
"acceptedAnswer": {
"@type": "Answer",
"text": "Les traitements incluent des antibiotiques, des interventions chirurgicales ou des remplacements."
}
},
{
"@type": "Question",
"name": "Comment gérer la douleur après une chirurgie de prothèse ?",
"position": 17,
"acceptedAnswer": {
"@type": "Answer",
"text": "Des analgésiques et des thérapies physiques aident à gérer la douleur post-opératoire."
}
},
{
"@type": "Question",
"name": "Quand envisager le remplacement d'une prothèse ?",
"position": 18,
"acceptedAnswer": {
"@type": "Answer",
"text": "Si la prothèse est usée, douloureuse ou provoque des complications, un remplacement est envisagé."
}
},
{
"@type": "Question",
"name": "Quels soins sont nécessaires après la pose d'un implant ?",
"position": 19,
"acceptedAnswer": {
"@type": "Answer",
"text": "Un suivi régulier, une bonne hygiène et des exercices de réhabilitation sont essentiels."
}
},
{
"@type": "Question",
"name": "Les prothèses nécessitent-elles un entretien ?",
"position": 20,
"acceptedAnswer": {
"@type": "Answer",
"text": "Oui, un suivi médical régulier est nécessaire pour surveiller l'état des prothèses."
}
},
{
"@type": "Question",
"name": "Quelles sont les complications possibles des prothèses ?",
"position": 21,
"acceptedAnswer": {
"@type": "Answer",
"text": "Les complications incluent l'infection, le rejet, la défaillance et la douleur chronique."
}
},
{
"@type": "Question",
"name": "Comment gérer une infection d'implant ?",
"position": 22,
"acceptedAnswer": {
"@type": "Answer",
"text": "Un traitement antibiotique et, si nécessaire, une intervention chirurgicale sont requis."
}
},
{
"@type": "Question",
"name": "Quels sont les signes d'une défaillance d'implant ?",
"position": 23,
"acceptedAnswer": {
"@type": "Answer",
"text": "Douleur accrue, instabilité ou bruit anormal peuvent indiquer une défaillance d'implant."
}
},
{
"@type": "Question",
"name": "Les prothèses peuvent-elles provoquer des douleurs chroniques ?",
"position": 24,
"acceptedAnswer": {
"@type": "Answer",
"text": "Oui, certaines personnes peuvent développer des douleurs chroniques après la pose d'une prothèse."
}
},
{
"@type": "Question",
"name": "Quelles sont les conséquences d'un rejet d'implant ?",
"position": 25,
"acceptedAnswer": {
"@type": "Answer",
"text": "Le rejet peut entraîner des douleurs, une inflammation et nécessiter un retrait de l'implant."
}
},
{
"@type": "Question",
"name": "Quels facteurs augmentent le risque d'infection après une chirurgie ?",
"position": 26,
"acceptedAnswer": {
"@type": "Answer",
"text": "Diabète, obésité et tabagisme augmentent le risque d'infection post-chirurgicale."
}
},
{
"@type": "Question",
"name": "L'âge influence-t-il le succès des implants ?",
"position": 27,
"acceptedAnswer": {
"@type": "Answer",
"text": "Oui, les personnes âgées peuvent avoir un risque accru de complications avec les implants."
}
},
{
"@type": "Question",
"name": "Quels antécédents médicaux sont des facteurs de risque ?",
"position": 28,
"acceptedAnswer": {
"@type": "Answer",
"text": "Antécédents de maladies auto-immunes ou d'infections augmentent le risque de complications."
}
},
{
"@type": "Question",
"name": "Le mode de vie affecte-t-il le succès des prothèses ?",
"position": 29,
"acceptedAnswer": {
"@type": "Answer",
"text": "Oui, un mode de vie sédentaire et une mauvaise alimentation peuvent nuire au succès des prothèses."
}
},
{
"@type": "Question",
"name": "Les allergies aux matériaux influencent-elles le choix d'implant ?",
"position": 30,
"acceptedAnswer": {
"@type": "Answer",
"text": "Oui, des allergies connues peuvent limiter les options d'implants disponibles pour un patient."
}
}
]
}
]
}
└─
Implant résorbable
Absorbable Implants
D020341
-
E07.695.025
└─
Bioprothèse
Bioprosthesis
D001705
-
E07.695.100
└─
Prothèse vasculaire
Blood Vessel Prosthesis
D001807
-
E07.695.110
└─
Prothèse à ancrage osseux
Bone-Anchored Prosthesis
D000077280
-
E07.695.118
└─
Interface os-implant
Bone-Implant Interface
D000069343
-
E07.695.125
└─
Implants mammaires
Breast Implants
D018427
-
E07.695.140
└─
Prothèses dentaires
Dental Prosthesis
D017266
-
E07.695.190
└─
Électrodes implantées
Electrodes, Implanted
D004567
-
E07.695.202
└─
Dispositifs de protection embolique
Embolic Protection Devices
D057505
-
E07.695.207
└─
Oeil artificiel
Eye, Artificial
D005137
-
E07.695.225
└─
Implants de drainage du glaucome
Glaucoma Drainage Implants
D020327
-
E07.695.250
└─
Prothèse valvulaire cardiaque
Heart Valve Prosthesis
D006350
-
E07.695.310
└─
Implants expérimentaux
Implants, Experimental
D020007
-
E07.695.340
└─
Prothèse articulaire
Joint Prosthesis
D007595
-
E07.695.400
└─
Lentilles intraoculaires
Lenses, Intraocular
D007910
-
E07.695.460
└─
Prothèse maxillofaciale
Maxillofacial Prosthesis
D008447
-
E07.695.510
└─
Implants orbitaires
Orbital Implants
D020273
-
E07.695.540
└─
Prothèse ossiculaire
Ossicular Prosthesis
D009998
-
E07.695.550
└─
Prothèse pénienne
Penile Prosthesis
D015917
-
E07.695.610
└─
Conception de prothèse
Prosthesis Design
D011474
-
E07.695.680
└─
Bouchons méatiques
Punctal Plugs
D000070635
-
E07.695.698
└─
Dispositif d'occlusion septale
Septal Occluder Device
D055989
-
E07.695.715
└─
Endoprothèses
Stents
D015607
-
E07.695.750
└─
Bandelettes sous-urétrales
Suburethral Slings
D053825
-
E07.695.752
└─
Structures d'échafaudage tissulaires
Tissue Scaffolds
D054457
-
E07.695.825
└─
Prothèse visuelle
Visual Prosthesis
D057488
-
E07.695.950
└─└─
Couronnes
Crowns
D003442
-
E07.695.190.088
└─└─
Piliers dentaires
Dental Abutments
D000044
-
E07.695.190.175
└─└─
Crochets dentaires
Dental Clasps
D016734
-
E07.695.190.180
└─└─
Prothèse dentaire implanto-portée
Dental Prosthesis, Implant-Supported
D019094
-
E07.695.190.185
└─└─
Restaurations dentaires permanentes
Dental Restoration, Permanent
D003793
-
E07.695.190.190
└─└─
Restaurations dentaires temporaires
Dental Restoration, Temporary
D003794
-
E07.695.190.192
└─└─
Facettes dentaires
Dental Veneers
D003801
-
E07.695.190.196
└─└─
Appareils de prothèse dentaire
Dentures
D003778
-
E07.695.190.200
└─└─
Obturateurs palatins
Palatal Obturators
D010158
-
E07.695.190.600
└─└─
Prothèse parodontale
Periodontal Prosthesis
D010515
-
E07.695.190.610
└─└─
Dent artificielle
Tooth, Artificial
D014093
-
E07.695.190.800
└─└─
Défibrillateurs implantables
Defibrillators, Implantable
D017147
-
E07.695.202.175
└─└─
Neurostimulateurs implantables
Implantable Neurostimulators
D058542
-
E07.695.202.381
└─└─
Filtres caves
Vena Cava Filters
D016306
-
E07.695.207.500
└─└─
Implant de Molténo
Molteno Implants
D018465
-
E07.695.250.500
└─└─
Prothèse de coude
Elbow Prosthesis
D058569
-
E07.695.400.300
└─└─
Prothèse de hanche
Hip Prosthesis
D006622
-
E07.695.400.400
└─└─
Prothèse de genou
Knee Prosthesis
D007720
-
E07.695.400.410
└─└─
Prothèses articulaires métal-métal
Metal-on-Metal Joint Prostheses
D061825
-
E07.695.400.705
└─└─
Prothèse d'épaule
Shoulder Prosthesis
D000072227
-
E07.695.400.852
└─└─
Lentilles intraoculaires multifocales
Multifocal Intraocular Lenses
D000075542
-
E07.695.460.500
└─└─
Prothèse mandibulaire
Mandibular Prosthesis
D008341
-
E07.695.510.500
└─└─
Coloration de prothèse
Prosthesis Coloring
D017797
-
E07.695.680.550
└─└─
Endoprothèses à élution de substances
Drug-Eluting Stents
D054855
-
E07.695.750.500
└─└─
Endoprothèses métalliques auto-expansibles
Self Expandable Metallic Stents
D000069322
-
E07.695.750.750
└─└─└─
Restauration coronoradiculaire
Post and Core Technique
D011176
-
E07.695.190.088.500
└─└─└─
Implants dentaires unitaires
Dental Implants, Single-Tooth
D019250
-
E07.695.190.183.185
└─└─└─
Réparation de restauration dentaire
Dental Restoration Repair
D058250
-
E07.695.190.190.250
└─└─└─
Inlays
Inlays
D007284
-
E07.695.190.190.350
└─└─└─
Bases d'appareil de prothèse dentaire
Denture Bases
D003819
-
E07.695.190.200.200
└─└─└─
Prothèse dentaire complète
Denture, Complete
D003824
-
E07.695.190.200.205
└─└─└─
Vernis protecteurs d'appareil de prothèse dentaire
Denture Liners
D003822
-
E07.695.190.200.210
└─└─└─
Overdenture
Denture, Overlay
D003828
-
E07.695.190.200.215
└─└─└─
Prothèse partielle conjointe
Denture, Partial
D003829
-
E07.695.190.200.220
└─└─└─
Neuroprothèses
Neural Prostheses
D058117
-
E07.695.202.381.500
└─└─└─└─
Prothèse dentaire complète immédiate
Denture, Complete, Immediate
D003825
-
E07.695.190.200.205.205
└─└─└─└─
Prothèse dentaire complète inférieure
Denture, Complete, Lower
D003826
-
E07.695.190.200.205.210
└─└─└─└─
Prothèse dentaire complète supérieure
Denture, Complete, Upper
D003827
-
E07.695.190.200.205.215
└─└─└─└─
Prothèse partielle fixe
Denture, Partial, Fixed
D003830
-
E07.695.190.200.220.220
└─└─└─└─
Prothèse dentaire partielle immédiate
Denture, Partial, Immediate
D003831
-
E07.695.190.200.220.225
└─└─└─└─
Prothèse dentaire partielle amovible
Denture, Partial, Removable
D003832
-
E07.695.190.200.220.230
└─└─└─└─
Prothèse dentaire partielle provisoire
Denture, Partial, Temporary
D003833
-
E07.695.190.200.220.235
└─└─└─└─
Attachement de précision
Denture Precision Attachment
D003834
-
E07.695.190.200.220.245
└─└─└─└─└─
Prothèse dentaire partielle fixe à liaison résine
Denture, Partial, Fixed, Resin-Bonded
D016379
-
E07.695.190.200.220.220.220
The study objective was to compare three-dimensional and two-dimensional imaging using computer-assisted systems (CASs) in clinical guidance for preoperative surgical planning for middle hepatic tumor...
A retrospective analysis was performed on 23 children who underwent surgery for middle hepatic tumors in our hospital from January 2016 to June 2022. The surgical resection plan was formulated by the ...
All the tumors were successfully removed according to the preoperative method developed using three-dimensional imaging. The postoperative short-term follow-up revealed that all patients were doing we...
Three-dimensional imaging with a computer-assisted surgery system is superior to two-dimensional imaging in the preoperative planning of pediatric hepatoblastoma....
A buccal opening guide provides better view and better irrigation. The aim of this study was to investigate the accuracy of this open-sleeve system....
Thirty duplicated maxillary models, each with six extraction sockets and four healed sites, were used. Based on the same digital plan, three modalities, sCAIS with open-sleeves, closed-sleeves, and fr...
Both sCAIS groups exhibited better accuracy than the free-hand group in two clinical scenarios. At healed sites, the closed-sleeve group showed a significantly fewer error than the open-sleeve group i...
In this in vitro investigation, open-sleeve sCAIS proved better accuracy than free-hand surgery for both delayed and immediate implant placement. Compared with a closed-sleeve sCAIS system, open sleev...
Dental implants have become the preferred treatment modality for the replacement of missing teeth. The success of implant therapies is dependent on the precision of the implant placement to effectivel...
To assess in vitro the workflow for alveolar ridge augmentation with customised 3D printed block grafts and simultaneous computer-assisted implant planning and placement....
Twenty resin mandible models with an edentulous area and horizontal ridge defect in the region 34-36 were scanned with cone beam computed tomography (CBCT). A block graft for horizontal ridge augmenta...
The mean deviation in the position of the block graft compared to the virtual plan amounted to 0.79 ± 0.13 mm. The mean deviation between the positions of the 20 block grafts measured 0.47 ± 0.2 mm, i...
Within the limitations of this in vitro study, it can be concluded that customised block grafts fabricated through CBCT, computer-assisted design and 3D printing allow alveolar ridge augmentation with...
An ultrasound (US)-based computer-assisted approach has the potential to improve the accuracy and precision of screw placement for the percutaneous fixation of scaphoid fractures and also reduce the r...
Transcatheter mitral valve-in-valve is an alternative to high-risk reoperation on a failing bioprosthesis. It entails specific challenges such as left ventricular outflow tract obstruction. We propose...
Previous navigation systems can determine the position of the "tracked" surgical instrument in CT images in the context of functional endoscopic sinus surgery (FESS), but do not provide any assistance...
The optimal implant position is a critical factor for long-term success in fully edentulous patients. Implants can be placed through conventional freehand, static computer-assisted implant surgery (CA...
Navigational strategies create a scenario whereby percutaneous needle-based interventions of the liver can be guided using both pre-interventional 3D imaging datasets and dynamic interventional ultras...
Using a custom biopsy phantom, three consecutive exercises were performed by both novices and experts (n = 26). The exercise came in three options: (1) US-guidance, (2) US-guidance with pre-interventi...
Kinematic analysis helped quantifying the visual assessment of the needle trajectories. Compared to US-guidance, novices yielded most improvements using Reg (PS...
Digitizing the movement trajectory allowed us to objectively assess the impact of needle-navigation strategies on percutaneous procedures. In particular, our findings suggest that these advanced techn...
In this cadaveric study, the accuracy of CAS guided mandibular and maxillary reconstruction including immediate dental implant placement in different Brown defect classes is assessed....
The virtual planning and surgical procedure was conducted according to a newly proposed Amsterdam UMC reconstruction protocol. Postoperative evaluation was performed according to a previously proposed...
Fourteen mandibular and 6 maxillary reconstructions were performed. Average mandibular angle deviations were 1.52°±1.32, 1.85°±1.58, 1.37°±1.09, 1.78°±1.37, 2.43°±1.52 and 2.83°±2.37, respectively for...
Promising levels of accuracy were achieved for all mandibular angles. Dental implant positions approached the preoperative preferred positions well, within the margin to manufacture prosthetic devices...